Minimed™ Quick-set™ MMT-396ATRecalls & reported problems

Unomedical A/S · Single use infusion set for subcutaneous infusion. The infusion set must be used as described in the Instruction for Use. · Class 2

All models of MiniMed Infusion Sets (58) · Minimed Quick-set (18)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 05705244024960), received between Aug 26, 2024 and Sep 23, 2026 — classified as 4 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Material Twisted/Bent” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 4 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Twisted/Bent4
  • Complete Blockage2
  • Infusion or Flow Problem2
  • Loss of or Failure to Bond2
  • Premature Separation2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Handling Problem1
  • Leak/Splash1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • Hyperglycemia4
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjurySep 23, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient faced hyperglycemia on (b)(6) 2026. The blood glucose was 230 mg/dl high for one to two hours and the patient was treated with insulin pump.

    Patient problems: Hyperglycemia

    MAUDE report 50865644 ↗
  • InjuryAug 21, 2026Material Twisted/Bent; Device Handling Problem

    It was reported that patient does not have sufficient subcutaneous tissue which led to bent cannula while insertion of infusion set and experienced hyperglycemia (blood glucose was 300) treated with pump on (b)(6) 2026.

    Patient problems: Hyperglycemia

    MAUDE report 50362382 ↗
  • MalfunctionAug 7, 2026Leak/Splash

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50170968 ↗
  • InjuryAug 6, 2026Complete Blockage; Material Twisted/Bent

    Patient problems: Hyperglycemia

    MAUDE report 50158085 ↗
  • MalfunctionAug 6, 2026Loss of or Failure to Bond; Premature Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50151729 ↗
  • InjuryApr 15, 2026Complete Blockage; Material Twisted/Bent

    IT WAS REPORTED ON 16-MAR-2026 THAT THE INFUSION SET CANNULA WAS BENT, WHICH ELEVATED THE GLUCOSE LEVEL TO 285 MG/DL AND WAS TREATED WITH A CORRECTION BOLUS VIA PUMP.

    Patient problems: Hyperglycemia

    MAUDE report 24887886 ↗
  • MalfunctionApr 4, 2026Loss of or Failure to Bond; Premature Separation

    IT WAS REPORTED THAT PATIENT FACED THAT TAPE NOT STICKING EVENT ON 05-MARCH-2026.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24784735 ↗
  • MalfunctionJul 4, 2025Infusion or Flow Problem; Infusion or Flow Problem

    REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES. IT WAS REPORTED THAT THE PATIENT FACED AN INSULIN FLOW BLOCKED ALARM EVENT ON (B)(6) 2025. THE BLOCKAGE WAS IN THE TUBING. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22401718 ↗
  • MalfunctionNov 28, 2024Infusion or Flow Problem; Infusion or Flow Problem

    REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES. IT WAS REPORTED THAT PATIENT FACED INSULIN FLOW BLOCKED ALARM EVENT ON 02-NOV-2024. THE INSULIN EXITED FROM THE TUBING GREATER THAN NORMAL RESISTANCE WITH PLUNGER PUSH. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20805206 ↗
  • MalfunctionAug 26, 2024Material Twisted/Bent; Material Twisted/Bent

    REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES. THIS MDR IS BEING SUBMITTED FOR AN UNKNOWN NUMBER OF DEVICES IN WHICH THE ISSUE WAS EXPERIENCED. ON 11-JUL-2024, REPORTED THAT PATIENT FACED INFUSION SET CRIMPED. INSERTION SITE WAS BELOW THE BELT LINE. INFUSION SET HAS BEEN USED FOR 2 DAYS. COMPANY DO NOT SEE BENT/KINKING AS BEING RELATED TO HUMAN FACTORS, BUT RATHER AS A TRAINING ISSUE INCLUDING CORRECT CHOICES OF INSERTION SITES AND INFUSION SETS AND CANNULA LENGTH. FURTHERMORE, THE SOFT CANNULA IS A FLEXIBLE MATERIAL THAT DURING USE AND UPON REMOVAL CAN BEND SLIGHTLY. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 20072785 ↗

Other Set, Administration, Intravascular devices

All Set, Administration, Intravascular devices →