Inion CompressOn™ Instrument 1 (REF IFS-9063)Recalls & reported problems

Inion Oy · K-wire Ø 0.8x150 mm · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 06438408008917), received between Feb 4, 2026 and Feb 4, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1
  • Material Split, Cut or Torn1

Patient problems

  • Infiltration into Tissue1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 4, 2026Fracture; Material Split, Cut or Torn

    AN OSTEOCHONDRAL TALUS FRACTURE WAS FIXED WITH 2.7 MM INION COMPRESSION SCREWS. AFTER SUCCESSFUL FIXATION OF THE FRACTURE FRAGMENT, A FLUOROSCOPY WAS TAKEN PRIOR TO WOUND CLOSURE. THE PICTURE REVEALED THAT THE 0.8 MM INION K-WIRE USED HAD BROKEN DURING THE OPERATION AND AN APPROXIMATELY 26 MM K-WIRE FRAGMENT REMAINED INSIDE THE TALUS BONE. THE SURGEONS DECIDED TO CLOSE THE SURGICAL WOUND AND TAKE A CT THE FOLLOWING DAY TO EVALUATE IF REOPERATION IS NEEDED TO REMOVE THE K-WIRE FRAGMENT. NO IMMEDIATE HARM OR CLINICAL DETERIORATION WAS OBSERVED. THE PATIENT UNDERWENT THE CT SCAN THE FOLLOWING DAY WHERE IT WAS EVALUATED THAT THE K-WIRE PASSES THROUGH THE BONE, BUT DOES NOT ENTER TO THE SUBTALAR JOINT, SO NO INTERVENTION WERE REQUIRED. CURRENTLY THE FRAGMENT DOES NOT CAUSE CLINICAL SYMPTOMS TO THE PATIENT. THIS INCIDENT IS CONSIDERED A MALFUNCTION AS THE K-WIRE BROKE UNEXPECTEDLY DURING OPERATION AND A FRAGMENT OF THE K-WIRE WAS LEFT INSIDE THE PATIENT. CURRENTLY THIS INCIDENT DOES NOT CAUSE CLINICAL SYMPTOMS TO THE PATIENT, NO CHANGE IN THE SURGICAL PLAN WAS IMPLEMENTED, THERE WAS NO DELAY IN OPERATION AND NO REOPERATION WAS DEEMED NECESSARY AT THIS POINT. THE FIXATION OF THE ACTUAL OS

    Patient problems: Infiltration into Tissue; No Clinical Signs, Symptoms or Conditions

    MAUDE report 24255865 ↗