Skip to content

Vial Adaptor 8072045Recalls & reported problems

West Pharma. Services Il, . Ltd · Vial Adapter 20mm FLL w/ Ribs - VF · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07290108240412), received between Jun 12, 2024 and Jun 12, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Contamination” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Contamination1
  • Contamination /Decontamination Problem1
  • Device Contaminated During Manufacture or Shipping1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 12, 2024Contamination; Contamination /Decontamination Problem; Device Contaminated During Manufacture or Shipping; Contamination; Contamination /Decontamination Problem; Device Contaminated During Manufacture or Shipping

    ON 13MAY2024, THE CUSTOMER, FERRING PHARMACEUTICALS, CONTACTED WEST PHARMA. SERVICES, IL LTD. (WEST IL), TO REPORT THAT DURING ASSEMBLY OF FERRING'S COMBINATION PACK, A VIAL ADAPTER, WAS OBSERVED WITH A BLUE FOREIGN PARTICULATE MATTER WITHIN THE PRIMARY STERILE PACKAGE. SUBSEQUENTLY, THE CUSTOMER OBSERVED A SECOND VIAL ADAPTER WITH ANOTHER BLUE FOREIGN PARTICULATE MATTER WITHIN THE PRIMARY STERILE PACKAGE. BOTH VIAL ADAPTERS ARE FROM LOT # F700. THE WEST PHARMA. VIAL ADAPTERS ARE CO-PACKED WITH THE DRUG FIRMAGON, THIS MEDICATION IS TO BE ADMINISTERED SUBCUTANEOUSLY AS AN INJECTION. BATCH RECORDS FOR LOT# F700 WERE REVIEWED AND THERE WERE NO NON CONFORMANCES FOUND. QUALITY CONTROL INSPECTIONS WERE CONDUCTED ACCORDING TO PROCEDURES DURING PRODUCTION, NO ISSUES WERE NOTICED. THE INCOMING INSPECTION RECORDS OF THE TYVEK AND NEEDLES WERE REVIEWED, NO ISSUES WERE NOTICED. LOT #F700 WAS MANUFACTURED ACCORDING TO RELEVANT PROCEDURES TESTED BEFORE RELEASE AND SHIPPED ACCORDING TO SPECIFICATIONS. RETAINED SAMPLES FROM LOT #F700 WERE 100% VISUALLY INSPECTED BY THE CONTRACT MANUFACTURER ACCORDING TO THEIR INTERNAL PROCEDURE, NO FINDINGS WERE OBSERVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19520328 ↗

Other Set, I.V. Fluid Transfer devices

All Set, I.V. Fluid Transfer devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.