Cannulated Tapered Pedicle Screw 88691Recalls & reported problems

Premia Spine Ltd · Cannulated Tapered Pedicle Screw 7.5X55[mm] used for fixation of spinal implants to the vertebrae. · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07290115933918), received between Sep 17, 2024 and Sep 17, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 17, 2024Fracture; Fracture

    THE COMPANY RECEIVED A REPORT THAT A PEDICLE SCREW TULIP BROKE DURING A SURGICAL PROCEDURE. FOLLOWING PEDICLE SCREW INSERTION, SET SCREWS WERE PLACED IN TULIPS. THE SURGEON STOOD ON PATIENT'S RIGHT SIDE AND ASSEMBLED COUNTER-TORQUE AND TORQUE LIMITER ON THE NEAREST TULIP, SLIDING COUNTER-TORQUE UP TO VISUALIZE THE TORQUE LIMITER'S DISTAL TIP. ATTEMPTS TO PLACE TORQUE LIMITER TIP INTO L4 RIGHT SET SCREW WERE DIFFICULT. A MALLET WAS USED TO HAMMER THE HANDLE OF TORQUE LIMITER TO DEEPEN THE TIP INTO THE SET SCREW. DEPTH OF TIP COULD NOT BE CONFIRMED AFTER MALLETING. WHEN THE FINAL TIGHTENER WAS TURNED ON FIRST SET SCREW, A LOUD POP WAS HEARD IN CONJUNCTION WITH THE SET SCREW FLYING ACROSS ROOM AND THE SIDEWALL OF TULIP LAYING ON OPERATING TABLE. THE SURGEON WAS LEANING BACK DURING THE TIGHTENING PROCESS. THIS CIRCUMSTANCE COULD ONLY HAPPEN IF THE COUNTER TORQUE WAS NOT LOCKED ON THE ROD AND SEATED OVER THE TULIP DURING THE TIGHTENING PROCESS. THE L4 RIGHT SCREW WAS REMOVED AND REPLACED WITH SAME SIZE SCREW (7.5X55MM). FUSION RODS AND SET SCREWS WERE PLACED AND THE SET SCREW INSERTER WAS USED TO TIGHTEN THE SET SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20240505 ↗