Baxter Healthcare Corporation · The Blood Warmer Disposable is a disposable circuit for use with the TherMax blood warmer in combination with other PrisMax disposable sets. · Class 2

All models of therMaxTherMax Blood Warmer (2)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 07332414123932), received between Jan 4, 2022 and Mar 2, 2026 — classified as 1 injury, 10 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak8
  • Device Contamination with Chemical or Other Material2
  • Adverse Event Without Identified Device or Use Problem1
  • Loose or Intermittent Connection1

Patient problems

  • No Clinical Signs, Symptoms or Conditions10
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 2, 2026Fluid/Blood Leak

    IT WAS REPORTED THAT AN EXTERNAL BLOOD LEAK WAS OBSERVED AT THE CONNECTION OF A PRISMAFLEX ST150 SET AND A THERMAX BLOOD WARMER DISPOSABLE DURING CONTINUOUS RENAL REPLACEMENT THERAPY. THE VOLUME OF BLOOD LOSS WAS NOT KNOWN. THE SET WAS REPLACED WITHOUT THE EXTRACORPOREAL BLOOD BEING RETURNED TO THE PATIENT. THERE WAS NO REPORT OF MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24489621 ↗
  • MalfunctionFeb 23, 2026Fluid/Blood Leak; Loose or Intermittent Connection

    IT WAS REPORTED THAT THE LUER LOCK CONNECTION BETWEEN A PRISMAFLEX ST150 SET AND A THERMAX BLOOD WARMER DISPOSABLE WAS LOOSE AND ALLOWED BLOOD LEAKAGE DURING CONTINUOUS RENAL REPLACEMENT THERAPY, DESCRIBED AS "BLOOD WAS SPRAYED OVER THREE NURSES". THE VOLUME OF BLOOD LOSS WAS NOT KNOWN. THE EXTRACORPOREAL BLOOD WAS NOT RETURNED TO THE PATIENT. THERE WAS NO REPORT OF MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24421541 ↗
  • MalfunctionJan 21, 2026Device Contamination with Chemical or Other Material

    IT WAS REPORTED THAT A "CONTAMINATE" WAS OBSERVED IN THE PORT TUBING OF A THERMAX BLOOD WARMER DISPOSABLE, DESCRIBED AS "CLEAR PORT HAS PAPER SHRED INSIDE". THIS WAS IDENTIFIED PRIOR TO USE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24136367 ↗
  • InjuryNov 19, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT CLOTTING WAS OBSERVED IN A THERMAX BLOOD WARMER DISPOSABLE DURING CONTINUOUS RENAL REPLACEMENT THERAPY WITH A PRISMAX MACHINE. IT WAS ADDITIONALLY REPORTED THAT THERE WAS A "POSSIBLE BLOOD ADMINISTRATION DUE TO FILTER LOSS". NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 23597761 ↗
  • MalfunctionOct 24, 2025Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT DURING PATIENT TREATMENT USING A THERMAX BLOOD WARMER, "THE CONNECTION/SNAP BETWEEN THE THERMAX BLOOD WARMER SET AND THE PRISMAFLEX SET BREAKS AND BLOOD STARTS FLOWING." TREATMENT WAS DISCONTINUED. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23383627 ↗
  • MalfunctionSep 26, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED A BLOOD LEAK WAS OBSERVED ORIGINATING AT THE CONNECTION BETWEEN THE THERMAX BLOOD WARMER DISPOSABLE AND A PRISMAFLEX ST150 SET DURING CONTINUOUS RENAL REPLACEMENT THERAPY. THE LEAK WAS ¿TOWARDS THE AIR SEPARATION CHAMBER". THE VOLUME OF BLOOD LOSS WAS APPROXIMATELY 200ML. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17817932 ↗
  • MalfunctionSep 6, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED AN EXTERNAL BLOOD LEAK WAS OBSERVED FROM A THERMAX BLOOD WARMER DISPOSABLE. THIRTY MINUTES INTO CONTINUOUS RENAL REPLACEMENT THERAPY THE LEAK WAS OBSERVED FROM THE LUER LOCK CONNECTION BETWEEN THE THERMAX DISPOSABLE AND THE RETURN BLOOD LINE OF THE PRISMAFLEX HP-X SET. TREATMENT WAS DISCONTINUED WITHOUT BLOOD RESTITUTION AND THE ACCUMULATED BLOOD LOSS WAS 192ML. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17691138 ↗
  • MalfunctionMay 31, 2023Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT DURING CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT) WITH A PRISMAX MACHINE EQUIPPED WITH A THERMAX BLOOD WARMER, A MINOR EXTERNAL BLOOD LEAK WAS OBSERVED FROM THE LUER LOCK CONNECTION BETWEEN THE THERMAX DISPOSABLE AND THE RETURN BLOOD LINE OF THE PRISMAFLEX ST150 SET, RESULTING IN A SMALL BLOOD CLOT. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17034099 ↗
  • MalfunctionSep 8, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT AFTER TEN HOURS OF CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT) WITH A PRISMAFLEX ST100 SET AND A PRISMAX MACHINE EQUIPPED WITH A THERMAX BLOOD WARMER, AN EXTERNAL BLOOD LEAK (179ML) WAS OBSERVED BETWEEN THE ST100 SET POSTER FILTER LUER CONNECTION AND THE THERMAX WARMER LUER CONNECTION. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15378544 ↗
  • MalfunctionMay 27, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THAT DURING CONTINUOUS RENAL REPLACEMENT THERAPY (CRRT) WITH A PRISMAX MACHINE EQUIPPED WITH A THERMAX BLOOD WARMER, A MINOR EXTERNAL BLOOD LEAK WAS OBSERVED FROM THE LUER LOCK CONNECTION BETWEEN THE THERMAX DISPOSABLE AND THE RETURN BLOOD LINE OF THE PRISMAFLEX ST150 SET, RESULTING IN A SMALL BLOOD CLOT. THE TREATMENT WAS ENDED AND THE EXTRACORPOREAL BLOOD WAS RETURNED TO THE PATIENT. THERE WAS NO REPORT OF PATIENT INJURY OR MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14522027 ↗
  • MalfunctionJan 4, 2022Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    IT WAS REPORTED THAT PARTICULATE MATTER (PM) WAS OBSERVED IN THE STERILE BAG TUBE OF A THERMAX BLOOD WARMER DISPOSABLE. THE PM WAS FURTHER DESCRIBED AS A ¿HAIR¿ AND WAS DISCOVERED PRIOR TO PATIENT USE. THERE WAS NO PATIENT INVOLVEMENT. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13158171 ↗

Other Dialyzer, high permeability with or without sealed dialysate system devices

All Dialyzer, high permeability with or without sealed dialysate system devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page