LoFric® Origo™ 44414 (REF 4441440)Recalls & reported problems

Wellspect AB · Single Use Urinary Catheter with salt solution. LoFric Origo, Tiemann 40cm CH14 / Coudé 16" 14FR, Sterile device. · Class 2

All models of LoFric Origo (12)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07333387043432), received between Feb 7, 2025 and Feb 9, 2026 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device Damaged Prior to Use” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Device Damaged Prior to Use1
  • Patient Device Interaction Problem1
  • Product Quality Problem1

Patient problems

  • Genital Bleeding1
  • Hemorrhage/Blood Loss/Bleeding1
  • No Clinical Signs, Symptoms or Conditions1
  • Urinary Tract Infection1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 9, 2026Product Quality Problem; Patient Device Interaction Problem

    MALE PATIENT, THAT HAS BEEN USING CATHETERS FOR A LONG TIME. RECENTLY SWITCHED FROM STRAIGHT TIP TO COUDE TIP. RECENTLY HE HAD TWO EPISODES OF BLEEDING, THE TWO EPISODES HAPPENED WITHIN TWO WEEKS TIME. THE FIRST BLEEDING LASTED A DAY AND SELF RESOLVED. THE SECOND TIME, THE PATIENT EXPERIENCED BLEEDING DURING EACH TIME HE CATHETERIZED DURING FOUR DAYS STRAIGHT, ONLY DURING CATHETERIZATION, NOT BEFORE OR AFTER. ON THE FOURTH DAY, WHICH WAS JANUARY 25TH, THE PATIENT WENT TO URGENT CARE. THE BLEEDING HAD THEN RESOLVED AND NO BLEEDING HAS OCCURED SINCE. WHEN HE WENT TO URGENT CARE, HE ALSO EXPERIENCED FEVER AND IRREGULAR HEART RATE. HE WAS DIAGNOSED WITH UTI AND TREATED WITH IV ANTIBIOTICS. ON JANUARY 30TH THE PATIENT WAS DISCHARGED FROM THE HOSPITAL. HE SAYS THAT HIS BLOOD PRESSURE IS OKEY NOW AND THAT HE IS FEELING OKEY BUT NOT GREAT. PATIENT WANTS TO SWITCH TO ANOTHER CATHETER BRAND. THE PATIENT DESCRIBED THE CATHETER TIP AS TOO SHARP AND THAT IT SCRATCHES THE URETHRA. HE SAYS THIS WAS A GENERAL COMPLAINT ABOUT THE COUDE TIP AND NOT SPECIFIC FOR ANY BATCH. ALSO, HE MENTIONED THAT THE COUDE INDICATOR RIDGE IS OFFSET AND THAT IT IS HARD TO REMEMBER TO CHECK THE SPECIFIC ORIENTATION. TH

    Patient problems: Genital Bleeding; Urinary Tract Infection

    MAUDE report 24290016 ↗
  • InjuryApr 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A MALE PATIENT WAS SENT A URINARY CATHETER OF THE WRONG SIZE (SMALLER THAN REQUIRED WITH A CURVED TIP) BY MISTAKE. PATIENT DISCOVERED THE MISTAKE AND REQUESTED AN EXPEDITE OF THE CORRECT CATHETER. THE USE OF WRONG CATHETER LED TO A MINOR BLEEDING AND PATIENT VISITED THE ER TO HAVE THIS CHECKED OUT. EVERYTHING WAS FINE AND PATIENT HAS RECOVERED. THE ERROR OCCURRED AT THE DISTRIBUTION LEVEL OF THE LOCAL WHOLESALER, WHERE THEY MIS-PICKED THE WRONG CATHETER TYPE AND SHIPPED IT TO THE PATIENT.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 21917255 ↗
  • MalfunctionFeb 7, 2025Device Damaged Prior to Use; Device Damaged Prior to Use

    PRODUCT PROBLEM OCCURRED OUTSIDE US, IN THE NETHERLANDS. A MALE USER OF LOFRIC ORIGO TIEMANN 40CM CH14 (STERILE SINGLE-USE INTERMITTENT URINARY CATHETER) DISCOVERED PRIOR TO USE THAT THE PRIMARY PACKAGE OF THE CATHETER WAS DAMAGED. THE PRIMARY PACKAGE (STERILE BARRIER) HAD A MISSING WELD AT THE LOWER END OF THE PACKAGING. THE PRODUCT WERE NOT USED AND NO HARM OR MEDICAL COMPLICATION WERE REPORTED. SEVERAL ATTEMPTS TO CONTACT USER HAVE BEEN MADE TO GATHER FURTHER INFORMATION ABOUT THE MALFUNCTION OF THIS DEVICE BUT WITH NO RESULT. THE AFFECTED CATHETERS WAS RETURNED TO MANUFACTURER FOR INVESTIGATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21331894 ↗

Other Catheter, straight devices

All Catheter, straight devices →