NA XFO012002Recalls & reported problems
Stryker GmbH · Standard Drill Bit , AO · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613252265320), received between Aug 30, 2022 and Oct 31, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Fracture2
Patient problems
- Foreign Body In Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 31, 2023Break; Fracture; Break; Fracture
IT WAS REPORTED BY THE CUSTOMER THAT THE DRILL BIT FROM THE EZ CLIP SET BROKE OFF INTO THE BONE OF THE PATIENT. DRILL BIT WAS NOT REMOVED FROM THE PATIENTS LEFT FOOT.
Patient problems: Foreign Body In Patient
MAUDE report 18044222 ↗MalfunctionAug 30, 2022Break; Fracture; Break; Fracture
PROCEDURE PERFORMED: ACHILLES TENDON LENGTHENING LEFT FOOT. TRIPLE ARTHRODESIS WITH INTERNAL FIXATION LEFT FOOT. THE TIP OF A 2MM DRILL BIT INADVERTENTLY BROKE OFF AND "APPEARED TO BE IMBEDDED IN THE AREA OF THE SINUS TARSI" OF THE LEFT FOOT DURING A PART OF THE PROCEDURE WHERE "AGGRESSIVE DRILLING OF THE BONE" TO STIMULATE CARTILAGE REPAIR WAS PERFORMED. SURGEON ATTEMPTED TO REMOVE IT, HOWEVER "DECIDED TO LEAVE IT IN PLACE DUE TO ITS'S BENIGN POSITION". SURGEON INDICATED HE WOULD DISCLOSE THIS TO THE PATIENT. THERE WAS NO MALFUNCTION OF DRILL. FDA SAFETY REPORT ID # MW5111089.
Patient problems: Foreign Body In Patient
MAUDE report 15325215 ↗
Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices
- NA 511.701Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT2,164 reports
- SmartLife 7126-120-000Stryker Corporation · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT1,065 reports
- NA 05.001.224Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT987 reports
- NA 05.001.206Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT632 reports
- NA 532.021Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT521 reports
- NA 2570-04-501Depuy (Ireland) · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT500 reports
- NA 532.110Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT433 reports
- NA 05.001.223Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT397 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page