Skip to content

GAMMA 3425-1320SRecalls & reported problems

Stryker GmbH · Long Nail Kit R1.5, Ti, RIGHT · Class 2 · Implant

All models of GAMMA (249)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07613252273813), received between Jul 20, 2021 and Sep 25, 2023 — classified as 4 injuries.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Fracture4
  • Break3

Patient problems

  • Failure of Implant4
  • Fall1
  • Implant Pain1
  • Nonunion/Delayed-union Bone Fracture1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjurySep 25, 2023Break; Fracture; Break; Fracture

    AS REPORTED: "FRACTURE OF THE IMPLANT IN THE CASE OF A DOMESTIC FALL EVENT THAT CANNOT BE RULED OUT. PATIENT HAD REVISION SURGERY THE NEXT DAY.

    Patient problems: Failure of Implant; Fall

    MAUDE report 17813871 ↗
  • InjuryAug 25, 2023Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT THE PATIENT'S RIGHT FEMUR WAS REVISED DUE TO NON-UNION OF A FEMORAL NECK FRACTURE. PRE-OP X-RAYS ALSO SHOWED A BROKEN DISTAL SCREW. INTRA-OPERATIVELY, THE NAIL WAS FOUND TO BE BROKEN WHERE THE LAG SCREW PASSES THROUGH THE NAIL. PATIENT WAS REVISED TO A HEMI HIP CONSTRUCT INCLUDING A RESTORATION MODULAR STEM CONSTRUCT.

    Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture

    MAUDE report 17625249 ↗
  • InjuryDec 20, 2022Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT AFTER A PATIENT CAME IN COMPLAINING OF PAIN, A X-RAY WAS TAKEN AND A FRACTURE OF THE IMPLANT WAS DETECTED ON (B)(6) 2022. THE REVISION SURGERY TOOK PLACE ON(B)(6) 2022.

    Patient problems: Failure of Implant; Implant Pain

    MAUDE report 16013859 ↗
  • InjuryJul 20, 2021Fracture; Fracture

    THE CUSTOMER INFORMED STRYKER THAT ON JUNE 24, DURING THE ME OF A GAMMA3 11MM 320 125-DEGREE NAIL ON THE RIGHT, THE NAIL BROKE IN THE IS BROKEN IN THE UPPER AREA.

    Patient problems: Failure of Implant

    MAUDE report 12196441 ↗

Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices

All ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices →