Triathlon 5550-G-391Recalls & reported problems
Howmedica Osteonics Corp. · Symmetric Patella · Class 2 · Implant
All models of Triathlon (608)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 7
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07613327014785), received between May 1, 2019 and Sep 18, 2023 — classified as 7 injuries.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture2
- Osseointegration Problem2
- Unstable2
- Degraded1
- Device Dislodged or Dislocated1
- Migration1
- Naturally Worn1
Patient problems
- Injury4
- Inadequate Osseointegration2
- Cyst(s)1
- Insufficient Information1
- Joint Laxity1
- Pain1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
InjurySep 18, 2023Degraded; Naturally Worn; Degraded; Naturally Worn
DURING A KNEE REVISION, THE SURGEON NOTICED A HORIZONTAL LINE/GROOVE ON THE MEDIAL SIDE OF A #6 LEFT CR CEMENTED FEMORAL COMPONENT. THE SURGEON ALSO NOTICED EXTREME WEAR ON THE MEDIAL SIDE OF A#6 9MM CS POLY INSERT AND WEAR ON THE SYMMETRICAL 39X11MM PATELLA. WHILE REMOVING THE LEFT FEMORAL COMPONENT FROM THE PT¿S FEMUR, THE SURGEON WAS ABLE TO REMOVE THE BROKEN FEMORAL SECTION OF THE COMPONENT. FEMORAL COMPONENT, TIBIAL POLY INSERT AND THE PATELLA WERE REPLACED.
Patient problems: Insufficient Information
MAUDE report 17762842 ↗InjuryNov 8, 2021Unstable; Unstable
IT WAS REPORTED THAT THE PATIENT'S RIGHT KNEE WAS REVISED DUE TO INSTABILITY AND A CYST FORMING UNDER THE PATELLAR COMPONENT. THE PATIENT WAS REVISED FROM AN 8X11 PS INSERT TO AN 8X11 TS INSERT AND THE 39MM SYMMETRIC PATELLA WAS SWAPPED FOR ANOTHER OF THE SAME SIZE. ASIDE FROM THE PROVIDED PRIMARY USAGE SHEET, REP CONFIRMED THAT NO FURTHER INFORMATION WILL BE RELEASED BY THE HOSPITAL OR SURGEON.
Patient problems: Cyst(s); Joint Laxity
MAUDE report 12775199 ↗InjuryAug 18, 2021Fracture; Migration; Fracture; Migration
THE FOLLOWING WAS REPORTED THAT: "3 SHEARED PATELLAR BLOCKS, MIGRATION OF THE PATELLA INTO THE FEMUR, PAIN". PATIENT REQUIRED REVISION SURGERY ON THE (B)(6) 2021.
Patient problems: Pain
MAUDE report 12336357 ↗InjuryJul 24, 2019Fracture; Device Dislodged or Dislocated; Fracture; Device Dislodged or Dislocated
POSTOPERATIVE DIAGNOSIS: PATIENT UNDERWENT LEFT TOTAL KNEE REPLACEMENT (B)(6) 2015. THE PATELLAR COMPONENT FRACTURED ACROSS THE PEGS. THE PATELLAR COMPONENT WAS LOOSE AND REMOVED. PATIENT UNDERWENT REVISION OF THE LINER ALSO ON (B)(6) 2019.
Patient problems: Injury
MAUDE report 8821681 ↗InjuryJul 2, 2019Unstable; Unstable
IT WAS REPORTED THROUGH THE COMMUNICATION OF AN ATTORNEY THAT ALLEGEDLY THE PATIENT WAS REVISED DUE TO" ONE YEAR STATUS POST CEMENTLESS LEFT TOTAL KNEE ARTHROPLASTY WITH ANTERIOR-POSTERIOR INSTABILITY."
Patient problems: Injury
MAUDE report 8754456 ↗InjuryJun 21, 2019Osseointegration Problem; Osseointegration Problem
IT WAS REPORTED THROUGH THE COMMUNICATION OF AN ATTORNEY THAT ALLEGEDLY THE PATIENT WAS REVISED DUE TO " LOOSE LEFT TOTAL KNEE".
Patient problems: Inadequate Osseointegration; Injury
MAUDE report 8721888 ↗InjuryMay 1, 2019Osseointegration Problem; Osseointegration Problem
POSTOPERATIVE DIAGNOSIS: THE PATIENT UNDERWENT LEFT TOTAL KNEE ARTHROPLASTY (B)(6) 2015. PATIENT HAD MECHANICAL COMPLICATION WITH LOOSE PATELLA POLYETHYLENE INPLANT, THE PATELLAR COMPONENT WAS REMOVED AND THE LINER WAS EXCHANGED (B)(6) 2018.
Patient problems: Inadequate Osseointegration; Injury
MAUDE report 8568467 ↗
Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices
- ATTUNE 1512-14-050Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER106 reports
- ATTUNE 1504-40-205Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall53 reports
- ATTUNE 1504-40-105Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall46 reports
- ATTUNE 1547-06-001Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall37 reports
- ATTUNE 1513-12-060Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER72 reports
- Triathlon 5521-B-300Howmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- Triathlon 5531-G-709-EHowmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- ATTUNE 1512-16-080Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page