Triathlon 5565-S-013Recalls & reported problems
Howmedica Osteonics Corp. · Fluted Stem · Class 2 · Implant
All models of Triathlon (608)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327026740), received between May 27, 2021 and May 27, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Loss of Osseointegration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Loss of Osseointegration1
Patient problems
- Inadequate Osseointegration1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 27, 2021Loss of Osseointegration; Loss of Osseointegration
IN PERFORMING FOLLOW-UP, REP PROVIDED A REVISION OPERATIVE REPORT FOR (B)(6) 2013 FOR THE PATIENT'S RIGHT KNEE. PREOPERATIVE DIAGNOSIS: LOOSE RIGHT REVISION KNEE ARTHROPLASTY WITH MALTRACKING OF PATELLA. OP REPORT NOTES: "IN LESS THAN 1 YEAR SHE DEVELOPED INCREASING PAIN AND DISCOMFORT. STUDIES ARE SUSPICIOUS FOR POSSIBLE LOOSENING OF FEMORAL COMPONENT. THERE WAS ONLY SOME DISTAL CEMENT AROUND THE FEMORAL COMPONENT. THE STEM APPEARED TO BE REACTIVE LINE AROUND IT SUGGESTING LOOSENING OF FEMORAL COMPONENT.THE PATELLA WAS ALSO TILTING AND MALTRACKING. FEMORAL COMPONENT CAME OUT VERY EASILY WITH NO FIXATION AT ALL. THE CEMENT WAS BONDED TO THE IMPLANT WITH AUGMENTS. THE STEM CAME OUT AND THERE WAS A FIBROUS MEMBRANE AROUND THE STEM COMPLETELY. THERE WAS NO CEMENT ON THE STEM AT ALL CONSISTENT WITH FEMORAL COMPONENT LOOSENING...WE HAD TO REMOVE THE PATELLAR COMPONENT TO POSITION IT MORE CENTRALLY.
Patient problems: Inadequate Osseointegration; Pain
MAUDE report 11899110 ↗
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.