Triathlon 5515-F-702Recalls & reported problems
Howmedica Osteonics Corp. · Posterior Stabilized Femoral · Class 2 · Implant
All models of Triathlon (608)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07613327040739), received between Feb 7, 2018 and Jul 9, 2023 — classified as 4 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Component Incompatible” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Component Incompatible1
- Contamination /Decontamination Problem1
- Insufficient Device Problem Information1
- Packaging Problem1
- Tear, Rip or Hole in Device Packaging1
- Unstable1
Patient problems
- Injury2
- No Consequences Or Impact To Patient2
- Bone Fracture(s)1
- Loss of Range of Motion1
- No Clinical Signs, Symptoms or Conditions1
- Scar Tissue1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryJul 9, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "REVISION RTKA. PERIPROSTHETIC FRACTURE DISTAL FEMUR, REVISED TO DFR."
Patient problems: Bone Fracture(s)
MAUDE report 17284221 ↗InjuryApr 1, 2021Component Incompatible; Component Incompatible
DURING A TRIATHLON TKA A PS FEM COMPONENT CEMENTED 5515-F-702, WAS OPENED AND IMPLANTED WITHOUT USING CEMENT. THE SURGEON¿S PLAN FOR THIS CASE WAS FOR A PRESS FIT KNEE, IN WHICH A PS FEM COMPONENT - BEADED W/PA SHOULD HAVE BEEN USED. A TITANIUM BASEPLATE AND A TITANIUM METAL BACKED PATELLA WERE CORRECTLY SELECTED AND IMPLANTED. THIS ISSUE WAS IDENTIFIED AFTER THE BILLING WAS DONE FOR THE CASE AND IT WAS NOTICED ON THE INVOICE THAT A CEMENTED PS FEM COMPONENT WAS IMPLANTED. THIS IDENTIFICATION OCCURRED AFTER THE MEDICAL PROCEDURE. SURGEON HAS PLANNED TO TAKE THE PATIENT BACK TO SURGERY TO REPLACE THE TKA CEMENTED FEMORAL COMPONENT WITH A PRESS FIT FEMORAL COMPONENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11601079 ↗InjuryJun 4, 2019Unstable; Unstable
IT WAS REPORTED THAT THE PATIENT'S RIGHT KNEE WAS REVISED AFTER PATIENT PRESENTED WITH A COMPLAINT IN (B)(6) 2018 (NATURE OF THE COMPLAINT NOT REPORTED TO REP). INTRA-OPERATIVELY, THE TIP OF THE DEVICE WAS BROKEN OFF AND ONE SIDE WAS WORN. UPDATE PER REVISION OPERATIVE REPORT: "MECHANICAL COMPROMISE OF RIGHT TOTAL KNEE ARTHROPLASTY WITH ASSOCIATED FLEXION INSTABILITY (PLY WEAR OF TIBIAL POLY INSERT) PLUS FRACTURE OF TIBIAL POLY INSERT POST...REVISION TOTAL KNEE ARTHROPLASTY (TIBIAL POLY EXCHANGE) WITH REMOVAL OF LOOSE BODY, LYSIS OF ADHESIONS, AND PARTIAL SYNOVECTOMY."
Patient problems: Injury
MAUDE report 8666694 ↗MalfunctionDec 28, 2018Packaging Problem; Packaging Problem
DUE TO OPERATIONS MISHANDLING OF THE IMPLANTS, THE OUTER PACKAGE (PACKAGE HAD BEEN WRAPPED TOO TIGHT, AND HANDLED TOO MANY TIMES - CAUSING THE INNER PACKAGE TO BREAK WITHIN THE CARDBOARD BOX). THE NURSE ALONG WITH THE SURGEON DEEMED THE IMPLANT UNSTERILE AND NOT USABLE FOR THE CASE. I REPORTED TO OPERATIONS AND MY OFFICE RIGHT AWAY, BUT DUE TO THE STICKER OF THE IMPLANT IN QUESTION BEING REPORTED ON A BILL SHEET - THE OFFICE INFORMED ME THAT A REPORT MUST BE SUBMITTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8203043 ↗MalfunctionNov 1, 2018Tear, Rip or Hole in Device Packaging; Contamination /Decontamination Problem; Tear, Rip or Hole in Device Packaging; Contamination /Decontamination Problem
FAULTY PACKAGING OF TRIATHLON PROSTHESIS. INNER CONTAINER WAS CRACKED AND STERILITY OF ITEM WAS COMPROMISED. ITEM COULD NOT BE USED FOR SURGERY. ANOTHER ITEM WAS SOURCED AND USED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8030708 ↗InjuryFeb 7, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
AS REPORTED: "PATIENT HAD FLEXION CONTRACTURE AND SOME LIMITED MOTION. REMOVED FEMORAL COMPONENT AND DOWNSIZED TO SIZE 6 FEMUR AND REMOVED SCAR TISSUE AND IMPLANTED STEM AND NEW POLY." OPERATIVE SIDE: RIGHT.
Patient problems: Injury; Loss of Range of Motion; Scar Tissue
MAUDE report 7247461 ↗
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page