Triathlon 5532-P-409Recalls & reported problems

Howmedica Osteonics Corp. · Tibial Bearing Insert · Class 2 · Implant

All models of Triathlon (608)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07613327042764), received between Dec 4, 2019 and Jan 11, 2024 — classified as 6 injuries.

The most frequently reported specific device problem is “Unstable” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unstable5
  • Adverse Event Without Identified Device or Use Problem1
  • Degraded1
  • Fracture1
  • Material Deformation1
  • Naturally Worn1

Patient problems

  • Joint Laxity4
  • Ambulation or Postural Difficulties1
  • Injury1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 11, 2024Unstable; Unstable

    IT WAS REPORTED THAT THE PATIENT'S RIGHT KNEE WAS REVISED DUE TO INSTABILITY. A 4X9 PS INSERT WAS REVISED TO A 4X14 PS INSERT. INTRA-OPERATIVELY, NOTHING WAS NOTED TO BE LOOSE, WORN, OR BROKEN.

    Patient problems: Joint Laxity

    MAUDE report 18491097 ↗
  • InjurySep 20, 2022Unstable; Unstable

    IT WAS REPORTED THE PATIENT'S RIGHT KNEE WAS REVISED DUE TO GLOBAL INSTABILITY (REP CONFIRMED THAT THERE WERE NO ALLEGATIONS OF INACCURATE CUTS OR IMPLANT MALPOSITION FROM THE PRIMARY). A 4X9 PS INSERT WAS REVISED TO A 4X11 TS INSERT.

    Patient problems: Joint Laxity

    MAUDE report 15459736 ↗
  • InjuryJul 22, 2022Degraded; Fracture; Unstable; Degraded; Fracture; Unstable

    THE FOLLOWING WAS REPORTED: PS INSERT REMOVAL AND REPLACEMENT OF NEW INSERT. ORIGINAL TKA OCCURRED APPROX. 12 YEARS AGO. PT PRESENTED WITH "MY KNEE FEELS LESS STABLE". PS INSERT POST HAS SNAPPED AND INSERT UPON REMOVAL PRESENTED YELLOW AND BRITTLE.

    Patient problems: Ambulation or Postural Difficulties

    MAUDE report 15089538 ↗
  • InjuryJun 15, 2022Unstable; Adverse Event Without Identified Device or Use Problem; Unstable; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED BY THE SALES REP THAT SURGEON INFORMED THAT MEDIAL LAXITY AND HYPEREXTENSION WHEN PATIENT EXTEND HIS LEG DETECTED THROUGH CLINICAL FINDING UPON CLINIC APPOINTMENT. EXPLANTED DONE AND REPLACED WITH TS IMPLANTS ( REVISION SURGERY) THIS IS A FIRST REVISION SURGERY , THE PRIMARY SURGERY WAS DONE ON (B)(6) 2020. PATIENT OUTCOME ( AS OF 25 MAY 2022) : AS THE REVISION SURGERY JUST BEEN DONE, PATIENT IS RECOVERING WELL.

    Patient problems: Joint Laxity

    MAUDE report 14700882 ↗
  • InjuryMar 25, 2021Unstable; Unstable

    IT WAS REPORTED THAT THE PATIENT'S LEFT KNEE WAS REVISED DUE TO GLOBAL INSTABILITY. A 4X9 PS INSERT WAS REVISED TO A 4X13 TS INSERT. REP PROVIDED USAGE FOR THE PRIMARY AND REVISION PROCEDURES, AND CONFIRMED THAT NO FURTHER INFORMATION WILL BE RELEASED BY THE HOSPITAL OR SURGEON.

    Patient problems: Joint Laxity

    MAUDE report 11572095 ↗
  • InjuryDec 4, 2019Material Deformation; Naturally Worn; Material Deformation; Naturally Worn

    WHILST RESURFACING PATELLA OF EXISTING TRIATHLON TOTAL KNEE REPLACEMENT, SURGEON DECIDED TO REPLACE PS INSERT FOR A THICKER SIZE. ON REMOVAL, THE INSERT APPEARED TO HAVE PITTING ON ARTICULAR SURFACE AND UNEVEN SURFACE ON THE BACK OF THE PS INSERT POST.

    Patient problems: Injury

    MAUDE report 9411854 ↗

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →