Triathlon 5532-G-811Recalls & reported problems
Howmedica Osteonics Corp. · Tibial Bearing Insert - PS · Class 2 · Implant
All models of Triathlon (608)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 07613327046359), received between Sep 28, 2018 and Nov 8, 2021 — classified as 5 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information2
- Adverse Event Without Identified Device or Use Problem1
- Break1
- Unstable1
Patient problems
- Injury4
- Unspecified Infection2
- Cyst(s)1
- Joint Laxity1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryNov 8, 2021Unstable; Unstable
IT WAS REPORTED THAT THE PATIENT'S RIGHT KNEE WAS REVISED DUE TO INSTABILITY AND A CYST FORMING UNDER THE PATELLAR COMPONENT. THE PATIENT WAS REVISED FROM AN 8X11 PS INSERT TO AN 8X11 TS INSERT AND THE 39MM SYMMETRIC PATELLA WAS SWAPPED FOR ANOTHER OF THE SAME SIZE. ASIDE FROM THE PROVIDED PRIMARY USAGE SHEET, REP CONFIRMED THAT NO FURTHER INFORMATION WILL BE RELEASED BY THE HOSPITAL OR SURGEON.
Patient problems: Cyst(s); Joint Laxity
MAUDE report 12775128 ↗InjuryOct 2, 2019Break; Break
SURGEON SCHEDULED REVISION KNEE SURGERY FOR PATIENT AFTER HE EXAMINED PATIENT AT OFFICE. PATIENT HAD INITIAL SURGERY ON (B)(6) 2012. IDENTIFIED AT REVISION SURGERY. SURGEON SUSPECTED POSSIBLE POST BREAKAGE PRIOR TO SURGERY. SURGEON PERFORMED REVISION SURGERY TO REPLACE PS INSERT IN WHICH THE POST SHEARED OFF OF TIBIAL INSERT.
Patient problems: Injury
MAUDE report 9145940 ↗InjuryOct 22, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT PATIENT'S RIGHT KNEE WAS REVISED DUE TO INFECTION (CAUSES OR CONTRIBUTORS TO INFECTION NOT REPORTED. UNKNOWN IF CLINICALLY CONFIRMED. INFECTING MICROORGANISM NOT IDENTIFIED TO REP). AN I&D WAS PERFORMED WITH A POLY SWAP. AN 8X11 PS INSERT WAS REVISED TO ANOTHER 8X11 PS INSERT.
Patient problems: Injury; Unspecified Infection
MAUDE report 7991763 ↗InjuryOct 18, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THROUGH THE SUBMISSION OF A REVISION IMPLANT SHEET THAT PATIENT'S LEFT KNEE WAS REVISED. AN 8X11 PS INSERT WAS SWAPPED FOR ONE OF A DIFFERENT LOT NUMBER.
Patient problems: Injury
MAUDE report 7981017 ↗InjurySep 28, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT PATIENT'S LEFT KNEE WAS REVISED DUE TO INFECTION (SURGEON IDENTIFIED INFECTION AS E. COLI. UNKNOWN IF INFECTION WAS CLINICALLY CONFIRMED). AN I&D WITH A POLY EXCHANGE FOR THE SAME CATALOG # WAS PERFORMED.
Patient problems: Injury; Unspecified Infection
MAUDE report 7918548 ↗
Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices
- ATTUNE 1512-14-050Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER106 reports
- ATTUNE 1504-40-205Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall53 reports
- ATTUNE 1504-40-105Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall46 reports
- ATTUNE 1547-06-001Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall37 reports
- ATTUNE 1513-12-060Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER72 reports
- Triathlon 5521-B-300Howmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- Triathlon 5531-G-709-EHowmedica Osteonics Corp. · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall19 reports
- ATTUNE 1512-16-080Depuy (Ireland) · PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page