Formula 0375941012Recalls & reported problems

Stryker Corporation · [Standard 12-Flute Barrel Bur, Arthroscopic Shaver Blade, Do Not Resterilize, Do Not Use if Package is Damaged, Keep Dry, Keep Away from Sunlight] · Class 1

All models of Formula (43)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
17
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 17 adverse event reports that list this exact device (DI 07613327054750), received between Jul 9, 2018 and Nov 11, 2025 — classified as 3 injuries, 14 malfunctions.

The most frequently reported specific device problem is “Break” (13 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break13
  • Device Contaminated During Manufacture or Shipping2
  • Adverse Event Without Identified Device or Use Problem1
  • Detachment of Device or Device Component1
  • Excessive Heating1
  • Insufficient Device Problem Information1
  • Material Separation1
  • Particulates1

Patient problems

  • No Known Impact Or Consequence To Patient8
  • No Clinical Signs, Symptoms or Conditions6
  • Insufficient Information3
  • Burn(s)1
  • Burn, Thermal1
  • Device Embedded In Tissue or Plaque1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 17 most recent of 17 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 11, 2025Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT FOREIGN MATERIAL WAS FOUND INSIDE THE PACKAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23528345 ↗
  • MalfunctionOct 10, 2022Break; Break

    IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. THE TIP WAS REMOVED FROM THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15573035 ↗
  • MalfunctionJun 15, 2022Break; Break

    IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. ALL PIECES WERE RETRIEVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14699137 ↗
  • MalfunctionJul 6, 2021Break; Break

    IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. ALL PIECES WERE RETRIEVED.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 12120700 ↗
  • MalfunctionJul 6, 2021Break; Break

    IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. ALL PIECES WERE RETRIEVED.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 12120695 ↗
  • MalfunctionFeb 4, 2021Material Separation; Break; Material Separation

    IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. ALL PIECES WERE RETRIEVED.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 11278884 ↗
  • MalfunctionJun 1, 2020Break; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE TIP OF THE DEVICE FELL OFF DURING THE PROCEDURE. THE PIECE WAS RETRIEVED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10105165 ↗
  • InjuryMar 4, 2020Break; Particulates; Break; Particulates

    IT WAS REPORTED THAT THE DEVICE BROKE AND POTENTIALLY REMAINS IN THE PATIENT.

    Patient problems: Device Embedded In Tissue or Plaque; No Consequences Or Impact To Patient

    MAUDE report 9787452 ↗
  • InjurySep 26, 2019Adverse Event Without Identified Device or Use Problem; Excessive Heating; Excessive Heating

    IT WAS REPORTED THAT THE DEVICE BURNED THE PATIENT.

    Patient problems: Burn(s)

    MAUDE report 9123956 ↗
  • MalfunctionApr 18, 2019Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT FOREIGN MATERIAL WAS FOUND INSIDE STERILE PACKAGING.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8529879 ↗
  • InjuryMar 14, 2019Insufficient Device Problem Information

    IT WAS REPORTED THAT THE PATIENT WAS BURNED.

    Patient problems: Burn, Thermal

    MAUDE report 8421162 ↗
  • MalfunctionDec 4, 2018Break

    IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. PLEASE NOTE ALL PIECES WERE RETRIEVED AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8129583 ↗
  • MalfunctionJul 31, 2018Break

    IT WAS REPORTED THAT THE TIP BROKE DURING A PROCEDURE. PER ADDITIONAL INFORMATION RECEIVED, THE PIECES FELL OFF OUTSIDE OF THE PATIENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7735626 ↗
  • MalfunctionJul 31, 2018Break

    IT WAS REPORTED THAT THE TIP BROKE DURING A PROCEDURE. PER ADDITIONAL INFORMATION RECEIVED, THE PIECES FELL OFF OUTSIDE OF THE PATIENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7735538 ↗
  • MalfunctionJul 31, 2018Break

    IT WAS REPORTED THAT THE TIP BROKE DURING A PROCEDURE. PER ADDITIONAL INFORMATION RECEIVED, THE PIECES FELL OFF OUTSIDE OF THE PATIENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7735532 ↗
  • MalfunctionJul 30, 2018Break

    IT WAS REPORTED THAT THE TIPS BROKE DURING THE PROCEDURE. THE PIECES FELL OFF OUTSIDE OF THE PATIENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7733015 ↗
  • MalfunctionJul 9, 2018Break

    IT WAS REPORTED THAT THE DEVICE BROKE DURING USE. ALL BROKEN PIECES WERE RETRIEVED AND PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7669806 ↗

Other BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL devices

All BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL devices →