Formula 0380545100Recalls & reported problems
Stryker Corporation · Tomcat, Angled Cutter · Class 1
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07613327055030), received between Jan 29, 2020 and Jul 2, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Device Contaminated During Manufacture or Shipping1
- Material Fragmentation1
- Material Integrity Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Insufficient Information2
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 2, 2025Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT SURGEON WAS USING AN ARTHROSCOPIC SHAVER BLADE DURING A RIGHT KNEE ARTHROSCOPY. THE SURGEON NOTED TINY METAL FRAGMENTS ON THE MONITOR INSIDE THE PATIENT'S KNEE. THE SURGEON DETERMINED THE METAL FRAGMENTS WERE FROM THE SHAVER BLADE. THE SURGEON REMOVED THE SHAVER BLADE FROM THE KNEE AND A NEW SHAVER BLADE WAS USED WITHOUT FURTHER INCIDENT. THE KNEE WAS IRRIGATED AT THE END OF THE SURGERY.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 22387627 ↗MalfunctionJul 23, 2024Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping
IT WAS REPORTED THAT THERE WAS FOREIGN MATERIAL IN THE STERILE PACKAGING.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19812412 ↗MalfunctionAug 4, 2022Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT THERE WAS FOREIGN MATERIAL IN THE STERILE PACKAGING.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 15163118 ↗MalfunctionJan 29, 2020Break
IT WAS REPORTED THAT THE DEVICE BROKE DURING THE PROCEDURE. ALL PIECES WERE RETRIEVED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9645015 ↗
Other BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL devices
- NA 511.801Synthes GmbH · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL223 reports
- Formula 0375544000Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL98 reports
- NA 0277096325Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL95 reports
- NA 310.25Synthes GmbH · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL91 reports
- Arthrex® AR-8400TDArthrex, Inc. · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL86 reports
- NA 0277096275Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL72 reports
- Arthrex® AR-7300DSArthrex, Inc. · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL70 reports
- NA 0277096277Stryker Corporation · BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL69 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.