AXSOS 705002Recalls & reported problems
Stryker GmbH · K-Wire Drill Tip · Class 1
All models of AXSOS (184)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327086157), received between Mar 29, 2019 and Dec 23, 2019 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 23, 2019Break; Break
THE CUSTOMER REPORTED THAT THE DRILL SNAPPED AND BECAME STUCK IN THE DRILL GUIDE. THE CASE WAS COMPLETED WITH A 2 MINUTE DELAY TO SURGERY. THE PATIENT WAS YOUNG WITH HARD BONE AND MAY HAVE PUT THE DRILL UNDER PRESSURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9512733 ↗MalfunctionMar 29, 2019Break
IT WAS REPORTED THAT, ON (B)(6) 2019, DR. WAS FIXING A DISTAL TIBIA FRACTURE. DURING THE IMPLANTING OF TWO DIFFERENT SCREWS, THE SCREWS SNAPPED AND BROKE IN HALF. ADDITIONALLY DURING DRILLING, THE TIP OF THE DRILL BIT BROKE IN THE PATIENT'S BODY. THE PROCEDURE WAS COMPLETED SUCCESSFULLY, AND NO ADVERSE CONSEQUENCES OR SURGICAL DELAY WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8464236 ↗
Other INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT devices
- NA 511.701Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT2,164 reports
- SmartLife 7126-120-000Stryker Corporation · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT1,065 reports
- NA 05.001.224Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT987 reports
- NA 05.001.206Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT632 reports
- NA 532.021Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT521 reports
- NA 2570-04-501Depuy (Ireland) · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT500 reports
- NA 532.110Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT433 reports
- NA 05.001.223Synthes GmbH · INSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT397 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.