Skip to content

REUNION 5573-2E-3606Recalls & reported problems

Stryker GmbH · GLENOSPHERE , 2mm ECCENTRIC · Class 2 · Implant

All models of REUNION (113)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07613327098907), received between Oct 4, 2018 and Mar 4, 2026 — classified as 7 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated3
  • Adverse Event Without Identified Device or Use Problem2
  • Material Fragmentation1
  • Naturally Worn1
  • Off-Label Use1
  • Unstable1

Patient problems

  • Bacterial Infection1
  • Bone Fracture(s)1
  • Discomfort1
  • Implant Pain1
  • Insufficient Information1
  • Joint Dislocation1
  • Joint Laxity1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 4, 2026Device Dislodged or Dislocated

    A REVISION SURGERY WAS PERFORMED DUE TO DISASSOCIATION OF THE GLENOSPHERE.

    Patient problems: Joint Dislocation

    MAUDE report 24507240 ↗
  • InjuryApr 10, 2024Unstable; Unstable

    THE PATIENT UNDERWENT A REVISION SURGERY. IN AN UPDATE, IT WAS MENTIONED THAT THE PATIENT WAS UNSTABLE, LEADING THE SURGEON TO CHANGE THE IMPLANTS TO ADDRESS THE INSTABILITY ISSUES. REUNION IMPLANTS WERE USED TO UPSIZE THE IMPLANTS AND WASH OUT THE PATIENT DURING THE SURGERY.

    Patient problems: Joint Laxity

    MAUDE report 19079459 ↗
  • InjuryNov 25, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "ACROMIAL STRESS FRACTURE NON-UNION. PATIENT EXPERIENCING PAIN OVER PROXIMAL AND DISTAL LOCKING BOLT SITES. REOPERATION TO REMOVE LOCKING BOLTS".

    Patient problems: Bone Fracture(s); Implant Pain

    MAUDE report 15864161 ↗
  • InjuryFeb 21, 2022Off-Label Use; Off-Label Use

    IT WAS REPORTED THAT THE WRONG SIZE/INCORRECT IMPLANT WAS OPENED AND IMPLANTED INTO A PATIENT. PATIENT HAD TO HAVE THE INCORRECT IMPLANT REMOVED AND THE CORRECT ONE IMPLANTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13569884 ↗
  • InjuryFeb 10, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated

    AS REPORTED: "THE SURGEON REVISED PATIENT TO NEW STEM, GLENOSPHERE, CUP AND LINER DUE TO REOCCURRING DISLOCATIONS." NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Insufficient Information

    MAUDE report 13508770 ↗
  • InjuryNov 9, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "AS REPORTED: "INTRA-OP CULTURES CAME BACK POSITIVE FOR P. ACNES. NO GROSS PURULENCE NOTED DURING SURGERY. PATIENT STARTED TAKING AMOXICILLIN ON (B)(6) 2020. CONTINUED FOLLOW-UP SCHEDULED WITH INFECTIOUS DISEASE CLINIC TO MONITOR."

    Patient problems: Bacterial Infection

    MAUDE report 10813521 ↗
  • InjuryOct 4, 2018Material Fragmentation; Device Dislodged or Dislocated; Naturally Worn

    PATIENT SAYS THAT PEOPLE IN THE NURSING HOME MIGHT HAVE CAUSED HIS PROBLEM BY PULLING HIM UP UNDER HIS ARM.. THE GLENOSPHERE HAD DISASSOCIATED FROM THE BASEPLATE, CAUSING HIM PAIN AND DISCOMFORT. THIS HAD BEEN OUT OF PLACE FOR AWHILE. HE HAD A FAIR AMOUNT OF METALLOSIS IN THE JOINT. BECAUSE OF WEAR ON THE BASEPLATE, EVERYTHING HAD TO BE CHANGED TO NEW COMPONENTS EXCEPT FOR THE STEM WHICH WAS FOUND TO BE INTACT AND NOT LOOSE. THIS WAS THE PATIENT'S RIGHT SHOULDER.

    Patient problems: Discomfort; Pain

    MAUDE report 7933764 ↗

Other PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED devices