PRO 705463Recalls & reported problems
Stryker GmbH · Farabeuf Clamp · Class 1
All models of PRO (10)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327131918), received between Jul 12, 2021 and Jul 12, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Slipped” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Slipped1
- Positioning Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 12, 2021Positioning Failure; Device Slipped; Positioning Failure; Device Slipped
AS REPORTED: "THE PHYSICIAN WAS ATTEMPTING TO REDUCE THE PELVIC WING TO THE SACRUM USING THE FARABEUF CLAMP. THE CLAMP CONTINUALLY SLIPPED AND WOULDN¿T LOCK PROPERLY. THE PHYSICIAN USED BOTH THE ANGLED AND THE STRAIGHT FARABEUF CLAMP DURING THE SURGERY BUT BOTH OF THEM KEPT COMING UNDONE. THESE CLAMPS ARE SUPPOSED TO STAY LOCKED ONCE THEY ARE POSITIONED." ADDITIONAL INFORMATION: PROCEDURE WAS COMPLETED USING SYNTHES CLAMPS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12150373 ↗
Other CLAMP devices
- ATTUNE 2544-00-001Depuy (Ireland) · CLAMP144 reports
- NA 2178-63-134Depuy (Ireland) · CLAMP137 reports
- ATTUNE 2545-01-055Depuy (Ireland) · CLAMP128 reports
- SPECIALIST 86-5035Depuy (Ireland) · CLAMP101 reports
- SPECIALIST 96-6670Depuy Orthopaedics, Inc. · CLAMP92 reports
- ATRAUMATA FB469RAesculap AG · CLAMP1 recall0 reports
- ATRAUMATA FB461RAesculap AG · CLAMP1 recall0 reports
- ATRAUMATA FB738RAesculap AG · CLAMP1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page