T2 ALPHA 2335-1136SRecalls & reported problems
Stryker GmbH · Femoral Nail PF, LEFT · Class 2 · Implant
All models of T2 ALPHA (123)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327285543), received between Sep 15, 2020 and May 17, 2023 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Nonunion/Delayed-union Bone Fracture1
- Unspecified Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 17, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE NAIL WAS REMOVED DUE TO A POSTOPERATIVE INFECTION.
Patient problems: Unspecified Infection
MAUDE report 16945065 ↗InjurySep 15, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE MANUFACTURER BECAME AWARE OF A POST MARKET CLINICAL FOLLOW-UP REPORT RECEIVED FROM UNIVERSITY OF LOUISVILLE, IN USA. THE TITLE OF THIS REPORT IS ¿A RETROSPECTIVE DATA COLLECTION OF THE TREATMENT OF FEMORAL FRACTURES WITH THE FEMORAL NAIL PIRIFORMIS FOSSA (PF) OF THE T2 ALPHA FEMUR ANTEGRADE GT/PF NAILING SYSTEM¿ WHICH IS ASSOCIATED WITH THE STRYKER ¿T2 ALPHA FEMUR ANTEGRADE GT/PF NAILING SYSTEM¿. THIS STUDY INCLUDES RESEARCH DONE ON 18 PATIENTS (19 CASES) REQUIRING SURGERY BETWEEN THE PERIOD MARCH 2019 AND OCTOBER 2019. IT WAS NOT POSSIBLE TO ASCERTAIN SPECIFIC DEVICE DETAILS FROM THE REPORT, OR TO MATCH THE EVENTS REPORTED WITH PREVIOUSLY REPORTED COMPLAINTS. THEREFORE, NEW COMPLAINT WAS INITIATED IN THE SYSTEM FOR THE POST-OPERATIVE COMPLICATION MENTIONED IN THE REPORT. THIS PRODUCT INQUIRY ADDRESSES NONUNION AND BROKEN PROXIMAL DISTAL SCREW FOR WHICH REVISION SURGERY WAS PERFORMED. THE REPORT STATES: ¿THE PATIENT WAS A (B)(6) YEARS OLD MALE, BMI 29.0, NEVER A SMOKER WITH A HISTORY OF DIABETES AND SEIZURES. HIS INJURY WAS DUE TO A MOTORCYCLE COLLISION AND WAS CLASSIFIED AS 32-C2 CLOSED FRACTURE. THE PATIENT HAD HYPERTROPHIC NONUNION, DEFINED AS NO SIGNS OF PROPER UNION ASSOCI
Patient problems: Nonunion/Delayed-union Bone Fracture
MAUDE report 10538311 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE Intramedullary Limb Lengthening System LSB5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page