T2 ALPHA 2335-0936SRecalls & reported problems
Stryker GmbH · Femoral Nail PF, LEFT · Class 2 · Implant
All models of T2 ALPHA (123)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327285635), received between Jan 12, 2023 and Jan 12, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- Ambulation or Postural Difficulties1
- Failure of Implant1
- Implant Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 12, 2023Break; Fracture; Break; Fracture
IT WAS REPORTED THAT A SUBTROCHANTERIC PROXIMAL FEMUR FRACTURE WAS TREATED WITH A T2 ALPHA PF NAIL. 5 WEEKS POST OP THE PATIENT REPORTS THAT AS SHE WAS WALKING AROUND HER HOME, SHE FELT AND HEARD A POP AND HER LEFT LEG GAVE OUT AND SHE WAS UNABLE TO AMBULATE AND HAD SEVERE PAIN. SHE HAD A REVISION SURGERY TO REMOVE THE BROKEN NAIL AND IT WAS REPLACED WITH A DEPUY SYNTHES 95 DEGREE BLADE PLATE WITH CORTICAL AND LOCKING SCREWS.
Patient problems: Ambulation or Postural Difficulties; Failure of Implant; Implant Pain
MAUDE report 16147214 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE Intramedullary Limb Lengthening System LSB5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page