Skip to content

EPIC II 2030Recalls & reported problems

Stryker Corporation · Class 2

Quick summary

This Stryker EPIC II 2030 is a powered adjustable hospital bed. The 34 reports mostly describe the bed giving inaccurate weight or position readings, mechanical problems such as reduced braking force, exposed bare wires, and unexpected movement, with no patient involvement described. No deaths or injuries were reported. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
34
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 34 adverse event reports that list this exact device (DI 07613327348231), received between Apr 24, 2018 and Apr 28, 2025 — classified as 34 malfunctions.

The most frequently reported specific device problem is “Incorrect Measurement” (15 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect Measurement15
  • Mechanical Problem12
  • Electrical /Electronic Property Problem3
  • Unintended System Motion3
  • No Audible Alarm1
  • Unintended Movement1
  • Use of Device Problem1

Patient problems

  • No Patient Involvement24
  • No Clinical Signs, Symptoms or Conditions10
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 25 most recent of 34 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 28, 2025Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THE DEVICE EXPERIENCED INCORRECT MEASUREMENT. NO ADVERSE CONSEQUENCE OR CLINICALLY RELEVANT DELAY IN TREATMENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21919408 ↗
  • MalfunctionJan 30, 2025Electrical /Electronic Property Problem; Electrical /Electronic Property Problem

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT(S), WHERE IT WAS REPORTED THE DEVICES EXPERIENCED ACCESSIBLE AC CURRENT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21273443 ↗
  • MalfunctionOct 25, 2024Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THE DEVICE EXPERIENCED INCORRECT MEASUREMENT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20535441 ↗
  • MalfunctionJul 26, 2024Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THE DEVICE EXPERIENCED SCALE MEASURED WEIGHT INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19839270 ↗
  • MalfunctionJul 27, 2021Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THE DEVICE EXPERIENCED AN INACCURATE SCALE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12235147 ↗
  • MalfunctionApr 22, 2021Electrical /Electronic Property Problem; Electrical /Electronic Property Problem

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THERE ARE EXPOSED BARE WIRES. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11710882 ↗
  • MalfunctionApr 22, 2021Mechanical Problem; Mechanical Problem

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THERE IS REDUCED/INADEQUATE BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11710878 ↗
  • MalfunctionFeb 9, 2021Mechanical Problem; Mechanical Problem

    IT WAS REPORTED THAT THE DEVICE HAD REDUCED/INADEQUATE BRAKE FORCE. NO PATIENT WAS AFFECTED AND NO ADVERSE CONSEQUENCE OR CLINICALLY RELEVANT DELAY IN TREATMENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11303098 ↗
  • MalfunctionJan 29, 2021Incorrect Measurement; Incorrect Measurement

    IT WAS REPORTED THAT THE DEVICE SCALE MEASURED WEIGHT INACCURATE. NO PATIENT WAS AFFECTED AND NO ADVERSE CONSEQUENCE OR CLINICALLY RELEVANT DELAY IN TREATMENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11251936 ↗
  • MalfunctionJan 26, 2021Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE.  THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11230997 ↗
  • MalfunctionJul 24, 2020Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES <NOE> 3 </NOE> MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10321334 ↗
  • MalfunctionJul 22, 2020Mechanical Problem; Mechanical Problem

    THIS REPORT SUMMARIZES <NOE> 1 </NOE> MALFUNCTION EVENT, WHERE IT WAS REPORTED THERE WAS REDUCED BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10309046 ↗
  • MalfunctionApr 28, 2020Unintended System Motion; Unintended System Motion

    THIS REPORT SUMMARIZES <NOE> 1 </NOE> MALFUNCTION EVENT, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10004900 ↗
  • MalfunctionApr 27, 2020Unintended System Motion; Unintended System Motion

    THIS REPORT SUMMARIZES <NOE> 1 </NOE> MALFUNCTION EVENT, WHERE IT WAS REPORTED THE DEVICE HAD PHANTOM MOTION.  THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10001488 ↗
  • MalfunctionApr 27, 2020Mechanical Problem; Mechanical Problem

    THIS REPORT SUMMARIZES <NOE> 3 </NOE> MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE DEVICE HAD REDUCED BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10001180 ↗
  • MalfunctionJan 28, 2020Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES <NOE> 1 </NOE> MALFUNCTION EVENT, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 9638817 ↗
  • MalfunctionJan 27, 2020Mechanical Problem; Mechanical Problem

    THIS REPORT SUMMARIZES <NOE> 3 </NOE> MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE DEVICE HAD REDUCED BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 9633995 ↗
  • MalfunctionOct 25, 2019Mechanical Problem; Mechanical Problem

    THIS REPORT SUMMARIZES <NOE> 7 </NOE> MALFUNCTION EVENT(S), WHERE IT WAS REPORTED THE DEVICE HAD REDUCED BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 9238816 ↗
  • MalfunctionOct 25, 2019Electrical /Electronic Property Problem; Mechanical Problem; Electrical /Electronic Property Problem; Mechanical Problem

    THIS REPORT SUMMARIZES <NOE> 1 </NOE> MALFUNCTION EVENT(S), WHERE IT WAS REPORTED THERE WERE EXPOSED BARE WIRES AND THE UNIT HAD REDUCED BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 9238807 ↗
  • MalfunctionOct 25, 2019Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES <NOE> 3 </NOE> MALFUNCTION EVENT(S), WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 9238806 ↗
  • MalfunctionJul 29, 2019Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 3 MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 8835840 ↗
  • MalfunctionApr 26, 2019Mechanical Problem; Mechanical Problem

    THIS REPORT SUMMARIZES 4 MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE UNIT HAD REDUCED BRAKE FORCE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 8554973 ↗
  • MalfunctionApr 26, 2019Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES 2 MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 8554964 ↗
  • MalfunctionJan 28, 2019Unintended System Motion; Unintended System Motion

    THIS REPORT SUMMARIZES <NOE> 2 </NOE> MALFUNCTION EVENTS, WHERE IT WAS REPORTED .THE BED HAD PHANTOM MOTION THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 8280995 ↗
  • MalfunctionJan 28, 2019Incorrect Measurement; Incorrect Measurement

    THIS REPORT SUMMARIZES <NOE> 4 </NOE> MALFUNCTION EVENTS, WHERE IT WAS REPORTED THE SCALE WAS INACCURATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 8280786 ↗

Other BED, AC-POWERED ADJUSTABLE HOSPITAL devices

All BED, AC-POWERED ADJUSTABLE HOSPITAL devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.