Xia 3 System - Serrato 482616545Recalls & reported problems
Stryker Corporation · Polyaxial Screw · Class 2 · Implant
All models of Xia 3 System - Serrato (36)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 17
- Deaths reported
- 0
- Injuries reported
- 6
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 17 adverse event reports that list this exact device (DI 07613327352658), received between Nov 7, 2018 and Nov 27, 2024 — classified as 6 injuries, 11 malfunctions.
The most frequently reported specific device problem is “Fracture” (10 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture10
- Use of Device Problem3
- Adverse Event Without Identified Device or Use Problem2
- Inadequacy of Device Shape and/or Size2
- Migration2
- Break1
- Crack1
- Loosening of Implant Not Related to Bone-Ingrowth1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
- Pain8
- No Consequences Or Impact To Patient2
- Injury1
- Tissue Damage1
- Vertebral Fracture1
Recent adverse event reports
The 17 most recent of 17 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 27, 2024Inadequacy of Device Shape and/or Size; Use of Device Problem; Inadequacy of Device Shape and/or Size; Use of Device Problem
IT WAS REPORTED THAT THE IDEAL SIZED XIA SERRATO POLYAXIAL SCREW WAS NOT AVAILABLE INTRA-OPERATIVELY, AND THAT SMALLER SIZED XIA SERRATO POLYAXIAL SCREWS WERE IMPLANTED INSTEAD. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY AND NO ADVERSE CONSEQUENCES TO THE PATIENT. THIS REPORT CAPTURES THE SECOND OF TWO XIA SCREWS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20791525 ↗MalfunctionNov 27, 2024Inadequacy of Device Shape and/or Size; Use of Device Problem; Inadequacy of Device Shape and/or Size; Use of Device Problem
IT WAS REPORTED THAT THE IDEAL SIZED XIA SERRATO POLYAXIAL SCREW WAS NOT AVAILABLE INTRA-OPERATIVELY, AND THAT SMALLER SIZED XIA SERRATO POLYAXIAL SCREWS WERE IMPLANTED INSTEAD. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY AND NO ADVERSE CONSEQUENCES TO THE PATIENT. THIS REPORT CAPTURES THE FIRST OF TWO XIA SCREWS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20790009 ↗MalfunctionOct 19, 2023Fracture; Fracture
IT WAS REPORTED THAT A PATIENT EXPERIENCED A POST-OPERATIVE SERRATO POLYAXIAL SCREW FRACTURE. REVISION SURGERY HAS NOT BEEN PERFORMED.
Patient problems: No Clinical Signs, Symptoms or Conditions; Pain
MAUDE report 17970077 ↗InjuryOct 19, 2023Fracture; Fracture
IT WAS REPORTED THAT APPROXIMATELY EIGHT MONTHS POST-OPERATIVELY A PATIENT WAS REVISED TO ADDRESS A SERRATO POLYAXIAL SCREW FRACTURE.
Patient problems: No Clinical Signs, Symptoms or Conditions; Pain
MAUDE report 17970012 ↗MalfunctionOct 19, 2023Fracture; Fracture
IT WAS REPORTED THAT A PATIENT EXPERIENCED A POST-OPERATIVE SERRATO POLYAXIAL SCREW FRACTURE. REVISION SURGERY HAS NOT BEEN PERFORMED.
Patient problems: No Clinical Signs, Symptoms or Conditions; Pain
MAUDE report 17969788 ↗MalfunctionJan 27, 2023Fracture; Fracture
A COMPANY REPRESENTATIVE REPORTED THAT A PATIENT EXPERIENCED POST-OPERATIVE FRACTURE OF TWO SERRATO SCREWS. THE PATIENT HAS NOT BEEN REVISED AND REVISION IS NOT CURRENTLY SCHEDULED. THIS REPORT CAPTURES THE SECOND OF TWO FRACTURED SCREWS.
Patient problems: Pain
MAUDE report 16258395 ↗MalfunctionJan 27, 2023Fracture; Fracture
A COMPANY REPRESENTATIVE REPORTED THAT A PATIENT EXPERIENCED POST-OPERATIVE FRACTURE OF TWO SERRATO SCREWS. THE PATIENT HAS NOT BEEN REVISED AND REVISION IS NOT CURRENTLY SCHEDULED. THIS REPORT CAPTURES THE FIRST OF TWO FRACTURED SCREWS.
Patient problems: Pain
MAUDE report 16258376 ↗MalfunctionJan 27, 2023Fracture; Fracture
A COMPANY REPRESENTATIVE REPORTED THAT A PATIENT EXPERIENCED POST-OPERATIVE FRACTURE OF TWO SERRATO SCREWS. THE PATIENT HAS NOT BEEN REVISED AND REVISION IS NOT CURRENTLY SCHEDULED. THIS REPORT CAPTURES THE FIRST OF TWO FRACTURED SCREWS.
Patient problems: Pain
MAUDE report 16258289 ↗MalfunctionJan 27, 2023Fracture; Fracture
A COMPANY REPRESENTATIVE REPORTED THAT A PATIENT EXPERIENCED POST-OPERATIVE FRACTURE OF TWO SERRATO SCREWS. THE PATIENT HAS NOT BEEN REVISED AND REVISION IS NOT CURRENTLY SCHEDULED. THIS REPORT CAPTURES THE SECOND OF TWO FRACTURED SCREWS.
Patient problems: Pain
MAUDE report 16258244 ↗InjuryJan 20, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A XIA SERRATO SCREW BROKE THE PEDICLE UPON IMPLANTATION INTO L2 INTRA-OPERATIVELY. NO DEVICE SPECIFIC ISSUES WERE REPORTED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT SURGICAL DELAY. THERE WERE NO ADVERSE CONSEQUENCES NOR MEDICAL INTERVENTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13311060 ↗InjuryFeb 4, 2021Migration; Migration
A PHYSICIAN REPORTED THAT A PATIENT WAS REVISED TO ADDRESS A LOOSE XIA SERRATO POLYAXIAL SCREW PLACED AT S1.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11279618 ↗InjuryJan 11, 2021Loosening of Implant Not Related to Bone-Ingrowth; Migration; Loosening of Implant Not Related to Bone-Ingrowth; Migration
IT WAS REPORTED THAT A SERRATO POLYAXIAL SCREW LOOSENED POST OPERATIVELY. PATIENT UNDERWENT REVISION SURGERY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11150003 ↗MalfunctionSep 30, 2020Use of Device Problem; Use of Device Problem
A PHYSICIAN REPORTED THAT A SERRATO POLYAXIAL SCREW, "BROKE OUT OF PEDICLE WHEN FINAL TIGHTENING." THE SURGERY WAS COMPLETED SUCCESSFULLY FOLLOWING A 30-MINUTE DELAY IN WHICH THE CONSTRUCT WAS EXTENDED BY ONE LEVEL TO ACCOMMODATE SKIPPING THE LEVEL WITH THE BROKEN PEDICLE.
Patient problems: Vertebral Fracture
MAUDE report 10610072 ↗MalfunctionAug 27, 2020Fracture; Fracture
A PHYSICIAN REPORTED THAT A SERRATO POLYAXIAL SCREW AT EITHER L4 OR L5 WAS SEEN TO BE FRACTURED DURING THE PATIENT'S SCHEDULED SIX-MONTH POST-OPERATIVE CHECK-UP. THE PATIENT HAS EXPERIENCED NO ADVERSE CONSEQUENCE AND REVISION IS NOT DEEMED NECESSARY BY THE PHYSICIAN.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 10463218 ↗InjuryAug 6, 2020Fracture; Fracture
IT WAS REPORTED THAT A SERRATO POLYAXIAL SCREW FRACTURED POST-OPERATIVELY. THE PATIENT IS EXPERIENCING BACK PAIN, HOWEVER, THERE ARE NO PLANS FOR REVISION AT THIS TIME.
Patient problems: Pain
MAUDE report 10374999 ↗MalfunctionAug 21, 2019Break; Fracture; Fracture
A PHYSICIAN REPORTED THAT, WHILE IMPLANTING A 6.5 MM SERRATO PEDICLE SCREW AT L-5 S1, THE PEDICLE BROKE. THE PHYSICIAN WAS ABLE TO COMPLETE THE PROCEDURE USING THE SAME SERRATO PEDICLE SCREW AT THE SAME LEVEL; NO EXTENSION OF THE CONSTRUCT WAS NECESSARY. THIS EVENT RESULTED IN A 10-MINUTE SURGICAL DELAY. NO ADVERSE CONSEQUENCE TO THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8915179 ↗InjuryNov 7, 2018Adverse Event Without Identified Device or Use Problem; Crack; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT UPON SCREW INSERTION L4 PEDICLE OUTER SIDE IS CRACKED. L4 WAS SKIPPED, CONSTRUCT EXTENDED TO FROM L3 TO L5. THERE IS NO ALLEGATION OF A DEVICE MALFUNCTION. THE MAJOR DAMAGE TO THE BONE WAS REPORTED.
Patient problems: Injury; Tissue Damage
MAUDE report 8048397 ↗
Other Thoracolumbosacral pedicle screw system devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page