Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327383249), received between Apr 26, 2023 and Apr 26, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

10 other recalls cover devices cleared under the same FDA submission (K172634, K173849); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 26, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    OPENED CR POLY IMPLANT WITH THE LOCKING RING ALREADY DISPLACED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16814553 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K172634, K173849. One submission often covers many models, so check the product and lot details in each record.

  • Z-1262-2024 · Feb 6, 2024 · Open, Classified
    X3 TRIATHLON CS INSERT NO 7 9 MM
  • Z-1260-2024 · Feb 6, 2024 · Open, Classified
    X3 TRIATHLON CS INSERT NO 6 10 MM
  • Z-1263-2024 · Feb 6, 2024 · Open, Classified
    NO 3 TRIATHLON TS PLUS TIB INS X3 POLY 11 MM
  • Z-1259-2024 · Feb 6, 2024 · Open, Classified
    X3 TRIATHLON CS INSERT NO 3 10 MM
  • Z-1265-2024 · Feb 6, 2024 · Open, Classified
    NO 4 TRIATHLON TS PLUS TIB INS X3 POLY 16 MM
  • Z-1261-2024 · Feb 6, 2024 · Open, Classified
    X3 TRIATHLON CS INSERT NO 6 11 MM
  • Z-1264-2024 · Feb 6, 2024 · Open, Classified
    NO 4 TRIATHLON TS PLUS TIB INS X3 POLY 11 MM
  • Z-1266-2024 · Feb 6, 2024 · Open, Classified
    NO 4 TRIATHLON TS PLUS TIB INS X3 POLY 16 MM
  • Z-1654-2023 · Apr 13, 2023 · Open, Classified
    TRIATHLON X3 TIBIAL BEARING INSERT PS #4 13MM Intended for knee replacement Catalog Number: 5532-G-413-E
  • Z-1653-2023 · Apr 13, 2023 · Open, Classified
    TRIATHLON X3 TIBIAL BEARING INSERT CS #3 12MM-Intended for knee replacement Catalog Number: 5531-G-312-E

Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices →