GAMMA 8425-2400SRecalls & reported problems
Stryker GmbH · Long Nail, RIGHT · Class 2 · Implant
All models of GAMMA (249)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327476040), received between Jun 12, 2024 and Jun 12, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Malposition of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Malposition of Device1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 12, 2024Malposition of Device; Malposition of Device
AS REPORTED: "ORIF WAS PERFORMED FOR A MALE PATIENT WITH RIGHT FEMORAL TROCHANTERIC FRACTURE. AFTER TIGHTENING THE SET SCREW, THE SURGEON FOUND THAT THE BONE HEAD COULD BE ROTATED WHILE THE NAIL WAS IMPLANTED. THUS, THE SURGEON ATTEMPTED TO LOOSEN THE SET SCREW TO ADJUST THE ROTATIONAL ALIGNMENT BY THE LAG SCREW. HOWEVER, THE SET SCREW WAS NOT LOOSENED EVEN THOUGH THE SURGEON TRIED TO TURN IT BOTH CLOCKWISE AND COUNTERCLOCKWISE. EVENTUALLY, THE LAG SCREW BEGAN TO TURN SLIGHTLY, SO THE SURGEON COMPLETED THE SURGERY BY ADJUSTING THE LAG SCREW AND RETIGHTENED THE SET SCREW WHILE THE SET SCREW DID NOT TURN SMOOTHLY EVEN AFTER ADJUSTING THE LAG SCREW."
Patient problems: Insufficient Information
MAUDE report 19522343 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.