GAMMA 8125-1170SRecalls & reported problems
Stryker GmbH · Trochanteric Nail · Class 2 · Implant
All models of GAMMA (249)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 14
- Deaths reported
- 0
- Injuries reported
- 9
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 07613327478877), received between Oct 22, 2024 and Aug 20, 2026 — classified as 9 injuries, 5 malfunctions.
The most frequently reported specific device problem is “Positioning Failure” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Positioning Failure4
- Adverse Event Without Identified Device or Use Problem3
- Device Damaged by Another Device3
- Malposition of Device3
- Migration2
- Break1
- Detachment of Device or Device Component1
- Fracture1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Insufficient Information3
- Pain3
- Perforation3
- Ambulation or Postural Difficulties1
- Discomfort1
- Foreign Body In Patient1
- Implant Pain1
Recent adverse event reports
The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.
InjuryAug 20, 2026Adverse Event Without Identified Device or Use Problem
As reported: "The patient returned to the hospital from a rehabilitation facility due to pain. Radiographic examination demonstrated cut-out of the SHS (Sliding Hip Screw) in a Gamma 4 nail. On 08-Jun, revision surgery was performed with implantation of a hip endoprosthesis."
Patient problems: Pain; Perforation
MAUDE report 50359650 ↗MalfunctionJul 10, 2026Malposition of Device
The following information was reported:Medial migrating of the lag screw withing Gamma4 intermediate nail.
Patient problems: Insufficient Information
MAUDE report 25785150 ↗InjuryJun 18, 2026Positioning Failure; Device Damaged by Another Device; Scratched Material
THE SALES REP REPORTED THAT WHEN IN USE, THE REAMER OSCILLATES ABNORMALLY. ADDITIONAL INFORMATION RECEIVED: THE PROCEDURE WAS COMPLETED, BUT THE OPERATING TIME WAS EXTENDED. THIS HAD AN IMPACT ON THE PATIENT, AS THE DRILL BIT RUBBED AGAINST THE NAIL, CAUSING TITANIUM DEBRIS TO ENTER THE PATIENT¿S BODY. TWO MOTORS WERE USED TO VERIFY THAT THE PROBLEM WAS NOT WITH THE DRILL CHUCK, BUT THE ISSUE PERSISTED. FOR THE PATIENT, THERE WAS AN INCREASED RISK OF INFECTION DUE TO THE LONGER PROCEDURE TIME AND MORE FREQUENT ENTRIES AND EXITS FROM THE OPERATING ROOM. INCREASED STERILIZATION VOLUME, LONGER OPERATING ROOM OCCUPANCY.
Patient problems: Foreign Body In Patient
MAUDE report 25548423 ↗MalfunctionJun 17, 2026Positioning Failure; Device Damaged by Another Device
AS REPORTED: "NAIL GOT DRILL-MARKED".
Patient problems: Insufficient Information
MAUDE report 25537872 ↗MalfunctionApr 1, 2026Mechanical Jam
THE CUSTOMER REPORTED THAT: "THE GAMMA NAIL GOT STUCK IN ITS NAIL HOLDER. IT WAS IMPOSSIBLE TO UNSCREW IT. SEE ATTACHED PHOTOS. THE PROCEDURE HAD TO BE REPEATED, REMOVING THE CERVICAL AND DISTAL SCREWS AND THE NAIL, USING A NEW NAIL HOLDER AND NEW IMPLANTS. THE NAIL CANNOT BE SEPARATED FROM ITS NAIL HOLDER AND IS SENT FOR STERILIZATION MOUNTED ON THE NAIL HOLDER. THIS RESULTS IN WASTED TIME, A LONGER PROCEDURE, AND EXCESSIVE USE OF MATERIALS.".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24759398 ↗InjuryMar 30, 2026Positioning Failure; Malposition of Device
THE CUSTOMER REPORTED THAT : "INSERTION OF A SHORT GAMMA NAIL IN A PATIENT SUFFERING FROM A LEFT INTERTROCHANTERIC FRACTURE. DATE: (b)(6)2026. SURGERY PROCEEDED WITHOUT INCIDENT, WITH POSTOPERATIVE X-RAYS TAKEN IMMEDIATELY AFTER SURGERY AND THEN THREE DAYS POSTOPERATIVELY, AS EXPECTED. THE PATIENT UNDERWENT THE USUAL POSTOPERATIVE MOBILIZATION. ONE MONTH LATER, THE PATIENT RETURNED FOR CONSULTATION DUE TO PAIN AND FUNCTIONAL IMPAIRMENT. THE X-RAY TAKEN AT THAT TIME SHOWED THAT THE CERVICAL SCREW OF THE NAIL HAD MIGRATED INTO THE SMALL PELVIS AND THAT THERE WAS NO CONTACT BETWEEN THE NAIL AND THE CERVICAL SCREW, DESPITE INTERNAL LOCKING HAVING BEEN PERFORMED IN ACCORDANCE WITH THE LABORATORY'S SURGICAL TECHNIQUE. THE PATIENT WAS HOSPITALIZED. THE PATIENT UNDERWENT A SECOND OPERATION TO REMOVE THE MATERIAL AND INSERT A HIP PROSTHESIS."
Patient problems: Ambulation or Postural Difficulties; Implant Pain
MAUDE report 24731891 ↗InjuryDec 30, 2025Migration; Migration
AS REPORTED: "THE SET SCREW CAME LOOSE FROM THE GAMMA 4 NAIL. THE DOCTOR DOESN'T KNOW WHEN IT CAME LOOSE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23922051 ↗MalfunctionOct 27, 2025Positioning Failure; Device Damaged by Another Device; Positioning Failure; Device Damaged by Another Device
AS REPORTED: "CUSTOMER WAS NOT ABLE TO HIT THE NAIL CORRECTLY WITH THE FEMORAL NECK SCREW DRILL. THE NAIL WAS HIT WITH THE DRILL, THIS ALSO HAPPENED WITH THE SECOND NAIL. THE NAIL HOLDING SCREWS SHOW SIGNS OF WEAR.".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23389627 ↗InjuryOct 20, 2025Malposition of Device; Malposition of Device
AS REPORTED: "THE INITIAL SURGERY TOOK PLACE ON (B)(6) 2025, XRAY IMAGE WAS THEN TAKEN ON (B)(6) 2025, ISSUE WAS FOUND THAT THE SHS MIGRATED MEDIALLY. EACH OPERATION WAS PERFORMED BY A DIFFERENT DOCTOR/CLINICAL TEAM; REVISION SURGERY PERFORMED ON (B)(6) 2025."
Patient problems: Perforation
MAUDE report 23342890 ↗InjuryAug 7, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "THE GAMMA NAIL HAS MIGRATED UPWARDS, WHILE THE FEMORAL HEAD INCLUDING NECK HAS COLLAPSED DOWNWARD, EVEN THOUGH THE GAMMA4 NAIL WAS IN PLACE." A REVISION SURGERY WAS REQUIRED.
Patient problems: Perforation
MAUDE report 22742581 ↗InjuryJun 20, 2025Migration; Migration
SUBJECT: (B)(6). STRYKER PEGASUS STUDY. MIGRATION PIN MIGRATED THROUGH BONE INTO MUSCLE. RELATIONSHIP TO DEVICE: DEFINITELY RELATED, RELATIONSHIP TO PROCEDURE: DEFINITELY RELATED.
Patient problems: Insufficient Information
MAUDE report 22297712 ↗InjuryMay 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "SUBJECT: (B)(6). STRYKER PEGASUS STUDY. PAIN: PATIENT HAS SOME SORENESS LATERALLY CONSISTENT WITH IRRITATION FROM THE LAG SCREW AFTER THE FRACTURE HEAD COMPRESSED AND HEALED."
Patient problems: Discomfort; Pain
MAUDE report 21993218 ↗InjuryFeb 28, 2025Break; Fracture; Break; Fracture
AS REPORTED: "IMPLANT FAILURE OF GAMMA4. PATIENT IS 83M WHO HAD GAMMA4 IMPLANTED ON (B)(6) 2024. 6 WEEKS POST OP, HAD PAIN AT SITE. REPORTEDLY NO TRAUMATIC EPISODE/FALL FROM PATIENT. NAIL HAS BROKEN AT LAG SCREW/NAIL INTERFACE. SURGEON SUGGESTS IT IS FROM IMPLANT FAILURE. SURGEON REMOVED AND REVISED CASE TO SYNTHES DHS.".
Patient problems: Pain
MAUDE report 21497078 ↗MalfunctionOct 22, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A CASE FOR AN INTERTROCHANTERIC FRACTURE, THE NAIL ATTACHED TO THE TARGETER WAS IMPACTED USING THE APPROPRIATE IMPACTOR. AFTER CONFIRMING THE POSITIONING VIA X-RAYS, IT WAS OBSERVED THAT THE TARGETER AND NAIL HAD SEPARATED. THE SURGICAL TEAM REMOVED THE TARGETER AND HARDWARE AND PROCEEDED WITH A DIFFERENT IMPLANT SYSTEM (GAMMA 3 INSTEAD OF GAMMA 4). THE SURGERY WAS COMPLETED , WITH NO ADVERSE PATIENT CONSEQUENCES OR NEED FOR MEDICAL INTERVENTION, THOUGH THERE WAS A SLIGHT SURGICAL DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20510610 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page