GAMMA 8125-2170SRecalls & reported problems
Stryker GmbH · Trochanteric Nail · Class 2 · Implant
All models of GAMMA (249)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 1
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07613327479348), received between Aug 28, 2024 and Mar 23, 2026 — classified as 1 death, 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Malposition of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Malposition of Device1
- Mechanical Jam1
- Positioning Failure1
Patient problems
- Perforation3
- Fall1
- Insufficient Information1
- Necrosis1
- No Clinical Signs, Symptoms or Conditions1
- Respiratory Insufficiency1
- Stroke/CVA1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
DeathMar 23, 2026Mechanical Jam
AS REPORTED: "UNABLE TO UNSCREW BOLT FROM THE NAIL- TRIED EVERYTHING, HAD TO REMOVE ALL IMPLANTS FROM PATIENT AND PUT IN GAMMA 3 NAIL. A GAMMA 3 11X180X125 NAIL WAS USED TO COMPLETE THE SURGERY".
Patient problems: Respiratory Insufficiency; Stroke/CVA
MAUDE report 24670353 ↗MalfunctionJan 22, 2026Positioning Failure
AS REPORTED: "MIS-DRILLING OCCURRED WHEN DRILLING INTO THE DISTAL SCREW HOLE. THE ACCURACY OF THE TARGET DEVICE WAS CHECKED AFTER SURGERY, AND NO PROBLEMS WERE FOUND."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24152038 ↗InjuryOct 20, 2025Malposition of Device; Malposition of Device
AS REPORTED: "THE INITIAL SURGERY TOOK PLACE ON (B)(6) 2025, XRAY IMAGE WAS THEN TAKEN ON (B)(6) 2025, ISSUE WAS FOUND THAT THE SHS MIGRATED MEDIALLY. EACH OPERATION WAS PERFORMED BY A DIFFERENT DOCTOR/CLINICAL TEAM; REVISION SURGERY PERFORMED ON (B)(6) 2025. RE-REVISION SURGERY PLANNED FOR (B)(6) 2025." THIS COMPLAINT CAPTURES THE 2ND PLANNED REVISION.
Patient problems: Perforation
MAUDE report 23342887 ↗InjuryOct 6, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "THE LAG SCREW CUT OUT. THE PATIENT HAD BEEN FOLLOWING INSTRUCTIONS. HOWEVER, THIS TIME IT WAS TRAUMATIC AVASCULAR NECROSIS CAUSED BY A FALL. THE EVENT WAS DISCOVERED ON (B)(6) 2025, AND THE NAIL WAS REMOVED AND AN ARTIFICIAL HEAD WAS IMPLEMENTED ON (B)(6) 2025."
Patient problems: Fall; Necrosis; Perforation
MAUDE report 23219834 ↗InjurySep 29, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AS REPORTED: "AFTER THE OPERATION, IT WAS CUT OUT."
Patient problems: Perforation
MAUDE report 23174948 ↗InjuryAug 28, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS REVISED FROM A TROCHANTERIC NAIL GAMMA4 NAIL TO A TOTAL HIP DUE TO THE ROTATION OF LAG SCREW NOT BEING MAINTAINED.
Patient problems: Insufficient Information
MAUDE report 20091631 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE Intramedullary Limb Lengthening System LSB5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.