GAMMA 1420-0110Recalls & reported problems
Stryker GmbH · Targeting Sleeve · Class 2
All models of GAMMA (249)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 07613327479911), received between Feb 14, 2024 and Sep 28, 2026 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Failure to Align” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Align7
- Device Difficult to Setup or Prepare2
- Positioning Failure2
- Positioning Problem2
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions10
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 28, 2026Failure to Align
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50917223 ↗MalfunctionApr 20, 2026Positioning Failure
AS REPORTED: "GAMMA TARGETER DISTAL SCREW MISSED THE NAIL. WE DO NOT THINK THE NAIL OR SCREW IS CONTRIBUTING TO THE FAILURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24927423 ↗MalfunctionFeb 6, 2026Positioning Failure
AS REPORTED: "DISTAL SCREW MISSED NAIL. EQUIPMENT DETERMINED TO BE DEFECTIVE BY SURGEON".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24279486 ↗MalfunctionJun 18, 2025Failure to Align; Failure to Align
AS REPORTED: " IN (B)(6) HOSPITAL (B)(6) WE WERE DOING A CASE AND THE K WIRE DIDN'T LINE UP WITH THE ROTATION OF THE JIG." THE SURGERY WAS COMPLETED SUCCESSFULLY BY OPENING A SECOND SET AND USING THE JIG. THERE WAS 30 MIN OF DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22287868 ↗MalfunctionJun 13, 2025Failure to Align; Failure to Align
AS REPORTED: "I WAS COVERING A SHORT GAMMA CASE AT (B)(6) HOSPITAL AND THE DISTAL TARGETER DIDN'T WORK, THE SURGEON COULD NOT PASS THE DRILL THROUGH THE DISTAL HOLE." "DISTAL LOCKING ON SHORT NAIL NOT FUNCTIONING. THE DRILL WAS TOUCHING THE NAIL, RATHER THAN GOING THROUGH IT. FREE HAND TECHNIQUE WAS USED TO FINISH THE PROCEDURE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22205179 ↗MalfunctionApr 17, 2025Device Difficult to Setup or Prepare; Failure to Align; Device Difficult to Setup or Prepare; Failure to Align
IT WAS REPORTED THAT: "DURING AN OPERATION ON (B)(6) 2025, THE SURGEON ENCOUNTERED A FEW DIFFICULTIES WHEN FITTING THE NAIL REF. (B)(4). APPARENTLY, THE CEPHALIC SCREW DID NOT FIT INTO THE NAIL." "MINI-ABUTMENT OF A VERY COMPLEX EPIPHYSEAL-DIAPHYSEAL FRACTURE. COMPLEX EPIPHYSEAL-DIAPHYSEAL FRACTURE. OPENING OF THE FASCIA LATA. DRILLING OF THE GREATER TROCHANTER. PLACEMENT OF REAMING GUIDE NAIL. REAMING TO DIAMETER 13 DIAPHYSEAL AND 14 METAPHYSEAL. PLACEMENT OF A NAIL DIAMETER 10, 125° CERVICAL ANGULATION, 240 LENGTH. PLACEMENT OF THE CERVICAL GUIDE PIN, WHICH WILL BE CHECKED FROM FRONT AND SIDE. CERVICAL REAMING. MEASURE LENGTH BACK TO 110. PLACE CERVICAL SCREW LENGTH 110 WHICH WILL BE LOCKED. PLACE DISTAL SCREW LENGTH TO 37.5. SCOPIC CHECK: TECHNICAL INCIDENCE, GIVEN THE ECCENTRICITY OF THE CERVICAL SCREW TO THE NAIL. ATTEMPT TO REDUCE THE OSTEOSYNTHESIS USING THE SAME MATERIAL WAS UNSUCCESSFUL. PATIENT'S CURRENT CONDITION: LONGER OPERATING TIME (60 MIN). ACTIONS TAKEN IN HOSPITAL TO MANAGE PATIENT: CHANGE OF EQUIPMENT AND CERCLAGE OF FRACTURE SITE. NAIL LENGTH 260, DIAMETER 10, ANGULATION 125°. PLACEMENT OF GUIDE WIRE, CHECKED FROM FRONT AND SIDE. BORE LENGTH 110. LOCKED 110 SCRE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21857136 ↗MalfunctionMar 10, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
THE TARGETING SLEEVE MOVEMENT OF THE GAMMA 4 WAS FAULTY. THE TARGETING SLEEVE HAD COME LOOSE FROM THE TARGET DEVICE DURING OPERATION DUE TO THE METAL PIN ATTACHED TO THE SLEEVE COMING LOOSE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21566054 ↗MalfunctionAug 20, 2024Failure to Align; Positioning Problem; Failure to Align; Positioning Problem
IT WAS REPORTED THAT DURING A PRIMARY HIP FRACTURE SURGERY, THE SURGEON SUSPECTED THAT A DRILL MIGHT HAVE HIT A NAIL THROUGH THE TROCARS. IT WAS ALSO REPORTED THAT THE SURGEON INITIALLY THOUGHT SHE WAS IN THE DYNAMIC HOLE, BUT SWITCHED TO STATIC AND THE DRILL WORKED AS EXPECTED. THE NAIL WAS NOT EXPLANTED AND NO DAMAGE TO THE DRILL TIP WAS REPORTED, AND THE SAME SET WAS USED TO FINISH THE CASE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20002372 ↗MalfunctionAug 2, 2024Failure to Align; Positioning Problem; Failure to Align; Positioning Problem
IT WAS REPORTED THAT THE PATIENT HAD A FRACTURED PROXIMAL FEMUR. THE GAMMA 4 SLEEVE'S BUTTON HAD POPPED OUT AND WAS NOT LOCKING IN, AND THE INTERMEDIATE SLEEVE WAS NOT ALIGNING PROPERLY WITH THE NAIL. A SECOND SET WAS OPENED TO COMPLETE THE SURGERY, ADDING 10-15 MINUTES TO THE PROCEDURE. A SECOND SET WAS USED TO COMPLETE THE CASE AND NO ISSUES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19900736 ↗MalfunctionFeb 14, 2024Device Difficult to Setup or Prepare; Failure to Align; Device Difficult to Setup or Prepare; Failure to Align
IT WAS REPORTED THAT THE SLEEVE FOR GAMMA4 WAS NOT WORKING CORRECTLY, IT WOULDN'T LOCK IN. 24-JAN-2024-UPDATE. INTRA-OP-SLEEVE WAS NOT LOCKING TO TARGETING GUIDE. TRIPLE SLEEVE TYPICALLY LINES INTO THE DRILL HOLE FOR THE NAIL BUT BECAUSE THE GUIDE WAS NOT ENGAGE IT WAS GOING POSTERIOR TO THE NAIL, AND THE NAIL WAS MISSED. HAD TO TAKE OFF THE GUIDES AND DO PERFECT CIRCLES AND COMPLETE THE SURGERY FREE HAND. LONGER OR TIME 20-25 MINS. METAL CIRCULAR PIECE NEEDED TO BE MALLETED DOWN TO FUNCTION AS EXPECTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18707517 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page