N/A LF1937Recalls & reported problems
Stryker Sustainability Solutions, Inc. · LigaSure Maryland Jaw, Without Nano-coating, 37cm, Open/Lap Sealer/Divider · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
Quick summary
This Stryker LigaSure Maryland Jaw is a reprocessed surgical sealer/divider used to clamp and cut tissue during laparoscopic procedures. Its 30 reports mostly describe the device failing to seal or coagulate, delivering unexpected energy, sticking to tissue, or having its tip break off or detach while in use. Three reports involved patient injury; no deaths were reported. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 32
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 32 adverse event reports that list this exact device (DI 07613327504897), received between Jan 12, 2022 and Sep 9, 2026 — classified as 3 injuries, 29 malfunctions.
The most frequently reported specific device problem is “Use of Device Problem” (9 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Use of Device Problem9
- Energy Output Problem8
- Activation Problem3
- Compatibility Problem3
- Detachment of Device or Device Component3
- Failure to Seal3
- Output Problem3
- Activation Failure2
Patient problems
- No Clinical Signs, Symptoms or Conditions23
- Insufficient Information9
Recent adverse event reports
The 25 most recent of 32 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 9, 2026Insufficient Device Problem Information
Patient problems: Insufficient Information
MAUDE report 50697476 ↗MalfunctionSep 9, 2026Insufficient Device Problem Information
Patient problems: Insufficient Information
MAUDE report 50697475 ↗MalfunctionJan 7, 2026Difficult to Open or Close; Activation Problem
IT WAS REPORTED THAT THE LIGASURE DID NOT OPEN AND DID NOT SEAL AS REQUIRED. THERE WAS NO PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23996690 ↗MalfunctionDec 9, 2025Activation Failure; Activation Failure
IT WAS REPORTED THAT THE DEVICE WOULD NOT SEAL/COAGULATE WHEN CLAMPING DOWN. AS REPORTED, THE DEVICE WAS REPLACED WITH A STRYKER DEVICE. THERE WAS NO PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23762479 ↗MalfunctionApr 16, 2025Use of Device Problem; Failure to Seal; Use of Device Problem; Failure to Seal
IT WAS REPORTED THAT THE CUTTING POTION OF THE LIGASURE DEVICE WORKED, BUT THE BIPOLAR FUNCTION FAILED SO BLEEDING WAS UNCONTROLLED. NO INFORMATION WAS PROVIDED REGARDING PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 21852371 ↗MalfunctionApr 16, 2025Failure to Seal; Failure to Seal
IT WAS REPORTED THAT THE LIGASURE STICKS TO TISSUE, MAKING IT HARD TO RELEASE. AS REPORTED, 3-4 BURNS WERE REQUIRED BEFORE HEMOSTASIS OCCURRED. NO INFORMATION WAS PROVIDED REGARDING PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 21852179 ↗MalfunctionJan 24, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED FOR LIGASURE THAT THE WORKING PART FELL APART. MULTIPLE ATTEMPTS WERE MADE TO OBTAIN ADDITIONAL INFORMATION. NO INFORMATION WAS PROVIDED REGARDING PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 21230577 ↗MalfunctionOct 17, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT THE TIP OF THE LAP MARYLAND BROKE AND WAS DISJOINTED. THERE WAS NO PATIENT INJURY REPORTED, AND THE COMPLAINANT IS NOT AWARE OF ANY MEDICAL INTERVENTION OR EXTENDED PROCEDURE TIME. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20476933 ↗InjurySep 4, 2024Continuous Firing; Continuous Firing
IT WAS REPORTED THAT REPROCESSED MARYLAND LIGASURE WAS NOT TURNING OFF WHEN NOT USED. THIS REQUIRED MEDICAL INTERVENTION. THE COMPLAINANT NOT AWARE OF ANY OTHER PATIENT INJURY OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 20136089 ↗MalfunctionAug 14, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT TOWARDS THE END OF THE CASE, THE DOCTOR WENT TO CUT TISSUE AND THE TIP OF THE LIGASURE FELL OFF. THE TIP OF LIGASURE STAYED HANGING ON DEVICE. THERE WAS NO PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19987460 ↗MalfunctionMay 24, 2024Activation Failure; Activation Failure
IT WAS REPORTED THAT WHEN GRASPING TISSUE, THE COMPLAINT DEVICE DID NOT ACTIVATE AND COMMENT ON THE CONSOLE SAID INCOMPLETE SEAL. THE COMPLAINT DEVICE WAS REPLACED AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION AND EXTENDED PROCEDURE TIME REPORTED WAS LESS THAN TEN MINUTES JUST TO REPLACE THE DEVICE. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19397536 ↗MalfunctionMay 24, 2024Output Problem; Output Problem
IT WAS REPORTED THE COMPLAINT DEVICE DIDN'T WORK AS THE PHYSICIAN TRIED TO CONNECT THE DEVICE TO THE GENERATOR BUT RECEIVED AN ERROR MESSAGE. THE COMPLAINT DEVICE WAS REPLACED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WAS NO PATIENT INJURY REPORTED. THE COMPLAINANT IS NOT AWARE OF ANY MEDICAL INTERVENTION OR EXTENDED PROCEDURE TIME. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19397522 ↗MalfunctionMay 24, 2024Output Problem; Output Problem
IT WAS REPORTED THE COMPLAINT DEVICE WOULD NOT SEAL. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION AND EXTENDED PROCEDURE TIME REPORTED WAS A FEW MINUTES. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19397436 ↗MalfunctionMay 24, 2024Use of Device Problem; Use of Device Problem
IT WAS REPORTED THE COMPLAINT DEVICE WAS WORKING EFFECTIVELY FOR 8-10 BITES THEN PROCEEDED TO NO LONGER SEAL PROPERLY. ENERGY WAS NOT EMITTING THROUGH DEVICE TO SEAL. GENERATOR PRODUCED ERROR READING FOR PROPER SEALING. GENERATOR HAS SOFTWARE 4.1.0.15 ACTIVE. THE COMPLAINT DEVICE WAS REPORTED TO HAVE BEEN REPLACED TO COMPLETE THE CASE. THERE WAS NO PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19397118 ↗MalfunctionApr 2, 2024Material Deformation; Packaging Problem; Material Deformation; Packaging Problem
IT WAS REPORTED THE DEVICE ARRIVED VISIBLY BROKEN AT THE JAWS WITH DAMAGE TO THE PACKAGING. THE COMPLAINT DEVICE WAS REPLACED AND THE PROCEDURE WAS REPORTED TO HAVE BEEN COMPLETED SUCCESSFULLY. THERE WAS NO PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19028124 ↗MalfunctionMar 28, 2024Material Deformation; Material Deformation
IT WAS REPORTED THE DEVICE ARRIVED VISIBLY BROKEN AT THE JAWS. THERE WAS NO REPORTED PATIENT INJURY OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS FOUR MINUTES. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18991597 ↗MalfunctionFeb 15, 2024Energy Output Problem; Energy Output Problem
IT WAS REPORTED THE DEVICE KEPT ALARMING INCOMPLETE SEAL CYCLE DURING THE CASE. THE COMPLAINANT IS NOT AWARE OF ANY PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME. HOWEVER, THE PROCEDURE WAS REPORTED TO HAVE BEEN COMPLETED SUCCESSFULLY. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: Insufficient Information
MAUDE report 18717281 ↗MalfunctionJan 16, 2024Energy Output Problem; Activation Problem; Energy Output Problem; Activation Problem
IT WAS REPORTED THE DEVICE WOULD NOT FIRE NOR SEAL AND THAT AN ERROR CODE APPEARED ON THE GENERATOR. THERE WAS NO PATIENT INJURY, MEDICAL INTERVENTION, OR EXTENDED PROCEDURE TIME REPORTED. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18522862 ↗MalfunctionJan 12, 2024Energy Output Problem; Compatibility Problem; Energy Output Problem; Compatibility Problem
IT WAS REPORTED WHEN THE SURGEON WAS CLAMPING ON TO TISSUE WHEN IT GAVE THE ERROR CODE OF 404, INCOMPLETE SEAL. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS 15 MINUTES. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18507339 ↗MalfunctionJan 12, 2024Energy Output Problem; Compatibility Problem; Energy Output Problem; Compatibility Problem
IT WAS REPORTED WHEN THE SURGEON WAS CLAMPING ON TO TISSUE WHEN IT GAVE THE ERROR CODE OF 404, INCOMPLETE SEAL. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS 15 MINUTES. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18506631 ↗MalfunctionJan 12, 2024Energy Output Problem; Compatibility Problem; Energy Output Problem; Compatibility Problem
IT WAS REPORTED WHEN THE SURGEON WAS CLAMPING ON TO TISSUE WHEN IT GAVE THE ERROR CODE OF 404, INCOMPLETE SEAL. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS 15 MINUTES. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18506218 ↗MalfunctionJan 12, 2024Energy Output Problem; Energy Output Problem
IT WAS REPORTED WHEN THE SURGEON WAS CLAMPING ON TO TISSUE WHEN IT GAVE THE ERROR CODE OF 404, INCOMPLETE SEAL. THERE WAS NO PATIENT INJURY OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS 15 MINUTES. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18506200 ↗MalfunctionJan 11, 2024Use of Device Problem; Use of Device Problem
IT WAS REPORTED THE DEVICE STOPPED WORKING DUE TO AN ISSUE WITH THE JAWS CLAMPING AND NOT RELEASING DURING THE SEALING PROCESS. THERE WAS NO PATIENT IMPACT OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS MINIMAL ONLY TO REPLACE THE DEVICE. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18499048 ↗MalfunctionJan 11, 2024Use of Device Problem; Output Problem; Use of Device Problem; Output Problem
IT WAS REPORTED THE DEVICE STOPPED WORKING DUE TO AN ISSUE WITH THE JAWS CLAMPING AND NOT RELEASING DURING THE SEALING PROCESS. THERE WAS NO PATIENT IMPACT OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS MINIMAL ONLY TO REPLACE THE DEVICE. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18499045 ↗MalfunctionJan 11, 2024Use of Device Problem; Activation Problem; Use of Device Problem; Activation Problem
IT WAS REPORTED THE DEVICE STOPPED WORKING DUE TO AN ISSUE WITH THE JAWS CLAMPING AND NOT RELEASING DURING THE SEALING PROCESS. THERE WAS NO PATIENT IMPACT OR MEDICAL INTERVENTION AND THE EXTENDED PROCEDURE TIME REPORTED WAS MINIMAL ONLY TO REPLACE THE DEVICE. THESE ARE COMMONLY USED DEVICES THAT ARE READILY AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18499025 ↗
Other ELECTROSURGICAL, CUTTING & COAGULATION ACCESSORIES, LAPAROSCOPIC & ENDOSCOPIC, REPROCESSED devices
- Medline LF4418CRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed3 recalls8 reports
- Medline LF1937CRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed2 recalls13 reports
- Medline LF1944CRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed2 recalls12 reports
- MEDLINE LF1837CRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed2 recalls4 reports
- Medline LF1844CRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed2 recalls1 report
- N/A LF1837Stryker Sustainability Solutions, Inc. · ELECTROSURGICAL, CUTTING & COAGULATION ACCESSORIES, LAPAROSCOPIC & ENDOSCOPIC, REPROCESSED70 reports
- MEDLINE LF1212ACRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed1 recall8 reports
- MEDLINE LF1637CRMedline Industries, Inc. · Electrosurgical, cutting & coagulation accessories, laparoscopic & endoscopic, reprocessed1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page