GAMMA 8160-0100SRecalls & reported problems

Stryker GmbH · Lag Screw · Class 2 · Implant

All models of GAMMA (249)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07613327510997), received between Mar 5, 2025 and Mar 30, 2026 — classified as 6 injuries.

The most frequently reported specific device problem is “Migration” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Migration4
  • Adverse Event Without Identified Device or Use Problem1
  • Break1
  • Device Dislodged or Dislocated1
  • Fracture1

Patient problems

  • Insufficient Information3
  • Perforation2
  • Ambulation or Postural Difficulties1
  • Failure of Implant1
  • Impaired Healing1
  • Implant Pain1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 30, 2026Migration

    THE CUSTOMER REPORTED THAT : "INSERTION OF A SHORT GAMMA NAIL IN A PATIENT SUFFERING FROM A LEFT INTERTROCHANTERIC FRACTURE. DATE: (b)(6)2026. SURGERY PROCEEDED WITHOUT INCIDENT, WITH POSTOPERATIVE X-RAYS TAKEN IMMEDIATELY AFTER SURGERY AND THEN THREE DAYS POSTOPERATIVELY, AS EXPECTED. THE PATIENT UNDERWENT THE USUAL POSTOPERATIVE MOBILIZATION. ONE MONTH LATER, THE PATIENT RETURNED FOR CONSULTATION DUE TO PAIN AND FUNCTIONAL IMPAIRMENT. THE X-RAY TAKEN AT THAT TIME SHOWED THAT THE CERVICAL SCREW OF THE NAIL HAD MIGRATED INTO THE SMALL PELVIS AND THAT THERE WAS NO CONTACT BETWEEN THE NAIL AND THE CERVICAL SCREW, DESPITE INTERNAL LOCKING HAVING BEEN PERFORMED IN ACCORDANCE WITH THE LABORATORY'S SURGICAL TECHNIQUE. THE PATIENT WAS HOSPITALIZED. THE PATIENT UNDERWENT A SECOND OPERATION TO REMOVE THE MATERIAL AND INSERT A HIP PROSTHESIS."

    Patient problems: Ambulation or Postural Difficulties; Implant Pain

    MAUDE report 24735739 ↗
  • InjuryFeb 6, 2026Migration

    IT WAS REPORTED THAT, DURING A POST-OPERATIVE CHECK-UP, MEDIALIZATION OF THE SHS WAS DETECTED. THE REVISION SURGERY WAS PERFORMED WITH G4 U-BLADE. NO FURTHER INFORMATION WAS PROVIDED.

    Patient problems: Insufficient Information

    MAUDE report 24277868 ↗
  • InjuryNov 20, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SUBJECT: (B)(6) STRYKER PEGASUS STUDY. NON-UNION (NO BONE CONSOLIDATION WITHIN 6 MONTHS) 6 MONTH VISIT; CT (B)(6) 2025; X-RAYS (B)(6) 2025. UPDATE DURING VISIT ON SITE: THE SITE WILL BE UPDATING THE TERM FROM NONUNION TO ¿DELAYED HEALING.¿ BONE CONSOLIDATION EVENTUALLY WAS ACHIEVED AS NOTED ON THE 12 MONTH VISIT ON (B)(6) 2025.

    Patient problems: Impaired Healing

    MAUDE report 23603092 ↗
  • InjuryOct 20, 2025Migration; Migration

    AS REPORTED: "THE INITIAL SURGERY TOOK PLACE ON (B)(6) 2025, XRAY IMAGE WAS THEN TAKEN ON (B)(6) 2025, ISSUE WAS FOUND THAT THE SHS MIGRATED MEDIALLY. EACH OPERATION WAS PERFORMED BY A DIFFERENT DOCTOR/CLINICAL TEAM; REVISION SURGERY PERFORMED ON (B)(6) 2025. RE-REVISION SURGERY PLANNED FOR (B)(6) 2025." THIS COMPLAINT CAPTURES THE 2ND PLANNED REVISION.

    Patient problems: Perforation

    MAUDE report 23342886 ↗
  • InjuryMar 26, 2025Device Dislodged or Dislocated; Migration; Device Dislodged or Dislocated; Migration

    IT WAS REPORTED BY THE CUSTOMER THAT A GAMMA4 LAG SCREW BACKED OUT DURING PROCEDURE. POSTOPERATIVELY THE LAG SCREW WAS SEEN BACKED OUT OF THE NAIL. REVISION OF GAMMA NAIL WAS NECESSARY DUE TO FAILED FIXATION.

    Patient problems: Insufficient Information; Perforation

    MAUDE report 21701322 ↗
  • InjuryMar 5, 2025Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT A PATIENT WAS REVISED DUE TO A BROKEN LAG SCREW.

    Patient problems: Failure of Implant; Insufficient Information

    MAUDE report 21526552 ↗

Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices

All ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices →