Target Tetra TG5411520Recalls & reported problems

Stryker Corporation · Detachable Coil · Class 2 · Implant

All models of Target Tetra (19)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07613327580099), received between Apr 22, 2024 and Sep 9, 2026 — classified as 1 injury, 7 malfunctions.

The most frequently reported specific device problem is “Premature Separation” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Premature Separation6
  • Adverse Event Without Identified Device or Use Problem1
  • Component Misassembled1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 9, 2026Premature Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50702706 ↗
  • MalfunctionJul 16, 2026Premature Separation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25841261 ↗
  • MalfunctionOct 23, 2025Premature Separation; Premature Separation

    ANALYSIS OF THE RETURNED DEVICE FOUND THAT THE SUBJECT COIL DETACHED PREMATURELY DURING USE. THERE WERE NO CLINICAL CONSEQUENCES TO THE PATIENT REPORTED AS A RESULT OF THIS EVENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23375704 ↗
  • MalfunctionJun 13, 2025Component Misassembled; Component Misassembled

    IT WAS REPORTED THAT WHEN THE RO MARKER (RADIOPACITY MARKER) ON THE PUSHER WIRE OF THE SUBJECT COIL WAS AT THE APPROPRIATE POINT LINED UP WITH THE PROXIMAL MICROCATHETER MARKER, IT APPEARED EXCESS SUBJECT COIL DELIVERY WIRE WAS OUTSIDE OF THE MICROCATHETER TIP. THE SUBJECT DEVICE WAS IMPLANTED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING ADDITIONAL COILS. NO ADDITIONAL INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22203923 ↗
  • MalfunctionOct 25, 2024Premature Separation; Premature Separation

    IT WAS REPORTED THAT DURING THE PROCEDURE A MICROCATHETER MIGRATED FROM THE TARGET SITE, THUS THE SUBJECT COIL WAS WITHDRAWN FROM IT. WHEN THE SUBJECT COIL WAS REINSERTED INTO THE MICROCATHETER AND BROUGHT TO THE TARGET LESION IT WAS DISCOVERED THAT THE MAIN COIL WAS MISSING. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20535568 ↗
  • MalfunctionOct 10, 2024Premature Separation; Premature Separation

    IT WAS REPORTED THAT SUBJECT COIL DETACHED EARLY WITHOUT USE OF THE DETACHER. THE SUBJECT COIL WAS IMPLANTED SAFELY IN THE PATIENT IN THE END. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20421709 ↗
  • InjurySep 11, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING THE COIL EMBOLIZATION PROCEDURE, WHEN THE DETACHMENT MARKER WAS ALIGNED TO DETACH THE SUBJECT COIL, THE COIL TAIL GREATLY EXCEEDED THE MICROCATHETER AND THE DELIVERY WIRE OF THE SUBJECT COIL APPEARED TO BE COMING OUT OF THE MICROCATHETER DISTAL TIP. CONTRAST WAS PERFORMED AND BLEEDING WAS OBSERVED, THEREFORE THE SUBJECT COIL WAS IMMEDIATELY DETACHED, AND ADDITIONAL COILS WERE IMPLANTED AS A MEDICAL INTERVENTION. THE THIRD TO FIFTH COILS COULD BE IMPLANTED WITHOUT ANY ISSUE AND THE BLEEDING STOPPED. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THE PATIENT'S IMMEDIATE PROGNOSIS WAS NOT SIGNIFICANTLY AFFECTED.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 20190388 ↗
  • MalfunctionApr 22, 2024Premature Separation; Premature Separation

    IT WAS REPORTED THAT DURING AN ANEURYSM EMBOLIZATION CASE, THE SUBJECT COIL WAS RE-SHEATHED TWICE AND WAS SEEN TO BE DETACHED FROM THE SUBJECT COIL DELIVERY WIRE DURING THE PROCEDURE AND COULD NOT BE FOUND. THE PHYSICIAN CONFIRMED THAT THE SUBJECT COIL WAS NOT IN THE BODY. THERE WERE NO CLINICAL CONSEQUENCES TO THE PATIENT REPORTED AS A RESULT OF THIS EVENT AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. UPDATED INFORMATION: THE SUBJECT COIL WAS RETURNED FOR ANALYSIS AND WAS EXAMINED, AND IT WAS DISCOVERED THAT THE REPORTED EVENT OF THE SUBJECT COIL BEING PREMATURELY DETACHED/SEPARATED DURING USE WAS NOT CONFIRMED. THE SUBJECT COIL DELIVERY WIRE WAS FOUND TO BE KINKED, MAIN COIL WAS STRETCHED, AND THE SUTURE WAS FOUND DAMAGED UPON RETURN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19150944 ↗

Other DEVICE, NEUROVASCULAR EMBOLIZATION devices

All DEVICE, NEUROVASCULAR EMBOLIZATION devices →