GAMMA 8325-0240SRecalls & reported problems

Stryker GmbH · Intermediate Nail, LEFT · Class 2 · Implant

All models of GAMMA (249)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 07613327593877), received between Jan 31, 2024 and Jul 28, 2026 — classified as 4 injuries, 7 malfunctions.

The most frequently reported specific device problem is “Positioning Failure” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 3 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure4
  • Fracture3
  • Device Damaged by Another Device2
  • Improper or Incorrect Procedure or Method1
  • Malposition of Device1
  • Unstable1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • Insufficient Information4
  • Perforation1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 28, 2026Fracture

    As reported: "Primary surgery was performed on (b)(6)2026. The nail broke off at the lag screw hole during postoperative follow-up.Revision surgery was performed on (b)(6)-2026, and Gamma4 was removed and DC nail of Hansson was implanted."

    Patient problems: Insufficient Information

    MAUDE report 50061358 ↗
  • MalfunctionJul 20, 2026Positioning Failure

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25881382 ↗
  • InjuryJul 6, 2026Unstable

    It was reported that, postoperatively, the distal screw came loose. A revision surgery was performed to replace the nail with a long nail. No further information was provided.

    Patient problems: Insufficient Information

    MAUDE report 25724687 ↗
  • MalfunctionApr 30, 2026Positioning Failure

    AS REPORTED: "THE GAMMA4 INTERMEDIATE NAIL WAS USED. DURING DRILLING FOR DISTAL LOCKING SCREW INSERTION, INTERFERENCE BETWEEN THE DRILL BIT AND THE NAIL WAS OBSERVED. DESPITE COMPLETING DRILLING TO THE CONTRALATERAL CORTEX AFTER MINOR ADJUSTMENT, ORBITING OCCURRED DURING SCREW INSERTION, RESULTING IN FAILURE TO INSERT ONE OF THE TWO DISTAL LOCKING SCREWS. DURING INSERTION OF THE DISTAL LOCKING SCREW, MISALIGNMENT FROM THE INTENDED POSITION OCCURRED, POTENTIALLY CAUSING UNNECESSARY ADDITIONAL BONE/TISSUE TRAUMA TO THE PATIENT."

    Patient problems: Perforation

    MAUDE report 25046345 ↗
  • MalfunctionApr 20, 2026Malposition of Device

    AS REPORTED: "AFTER INSERTING THE GAMMA4 INTERMEDIATE NAIL AND DRILLING FOR THE DISTAL LOCKING SCREW, THE DRILL BIT AND THE NAIL INTERFERED WITH EACH OTHER, AND AS A RESULT, WE WERE UNABLE TO INSERT ONE OF THE TWO LOCKING SCREWS."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24932110 ↗
  • InjuryMar 19, 2026Fracture

    AS REPORTED: "THE PATIENT UNDERWENT A REVISION SURGERY DUE TO THE NAIL BREAKING AT THE LAG SCREW JUNCTION".

    Patient problems: Insufficient Information

    MAUDE report 24640810 ↗
  • MalfunctionMar 10, 2026Positioning Failure

    AS REPORTED: "DURING THE PRE-DRILLING INTERFERENCE CHECK, THE DRILL BIT WAS FOUND TO HAVE SLIGHT INTERFERENCE WITH THE DISTAL LATERAL STOP HOLE. IT WAS USED AS IS, AND DURING DRILLING, THE BIT DEVIATED FROM THE HOLE, SO DRILLING WAS PERFORMED WHILE HOLDING THE SLEEVE. THE PRIMARY COMPLAINT IS THAT THE INTERMEDIATE TARGETING SLEEVE FELT STIFF DURING USE."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24560302 ↗
  • MalfunctionDec 17, 2025Positioning Failure; Positioning Failure

    AS REPORTED: "OUT OF BONE DURING DRILLING IN THE DISTAL DYNAMIC HOLE. RETRIED WITH THE DEVICE AND THE PROCEDURE WAS COMPLETED."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23834447 ↗
  • InjuryDec 3, 2025Fracture; Device Damaged by Another Device; Fracture; Device Damaged by Another Device

    AS REPORTED: "LEFT INTERMEDIATE GAMMA NAIL BROKE AT THE STATIC SCREW HOLE".

    Patient problems: Insufficient Information

    MAUDE report 23707111 ↗
  • MalfunctionOct 18, 2024Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    IT WAS REPORTED AFTER THE FIRST USE OF GAMMA 4 WITHOUT THE PRESENCE OF THE SALES REP, THE DOCTOR NOTICED THAT HE FORGOT TO TIGHTEN THE SET SCREW.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20483716 ↗
  • MalfunctionJan 31, 2024Device Damaged by Another Device; Device Damaged by Another Device

    AS REPORTED: "G4 INTERMEDIATE NAIL MISS DRILL WAS OCCURRED ON LATERAL SIDE DURING DRILLING OF DISTAL DYNAMIC HOLE. PRE-CALIBRATION SHOWED CORRECT TARGETING. THE CORTICAL BONE AND NAIL WERE IN CONTACT AT THE LATERAL END, AND THE PHYSICIAN DETERMINED THAT THE MISS DRILL WAS DUE TO LOADING ON THE NAIL."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18620127 ↗

Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices

All ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page