Elecsys Anti-HBs 08343594160Recalls & reported problems
Roche Diagnostics GmbH · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613336154014), received between Jan 24, 2024 and Apr 26, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “False Negative Result” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- False Negative Result1
- False Positive Result1
- Incorrect, Inadequate or Imprecise Result or Readings1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 26, 2024False Positive Result; Incorrect, Inadequate or Imprecise Result or Readings; False Positive Result; Incorrect, Inadequate or Imprecise Result or Readings
THE INITIAL REPORTER STATED THEY RECEIVED QUESTIONABLE RESULTS FOR ONE PATIENT SAMPLE TESTED WITH ELECSYS ANTI-HBS ON TWO COBAS E 801 ANALYTICAL UNIT ANALYZERS. ALL VALUES > 11.5 IU/L INDICATE A POSITIVE VALUE. THE SAMPLE INITIALLY RESULTED IN AN ANTI-HBS VALUE OF > 1000 IU/L WITH A DATA FLAG. THE SAMPLE WAS AUTOMATICALLY REPEATED BY THE ANALYZER AT A 1:100 DILUTION, RESULTING IN AN ANTI-HBS VALUE OF < 350 IU/L WITH A DATA FLAG. THE CUSTOMER MANUALLY DILUTED THE SAMPLE 1:2 AND REPEATED IT, RESULTING IN A RAW VALUE OF 871 IU/L, WHICH CALCULATES TO A FINAL ANTI-HBS VALUE OF 1742 IU/L WHEN ACCOUNTING FOR THE DILUTION FACTOR. THE CUSTOMER MANUALLY DILUTED THE SAMPLE 1:5 AND REPEATED IT, RESULTING IN A RAW VALUE OF 271 IU/L, WHICH CALCULATES TO A FINAL ANTI-HBS VALUE OF 1355 IU/L WHEN ACCOUNTING FOR THE DILUTION FACTOR. THE SAMPLE WAS REPEATED WITHOUT DILUTION, RESULTING IN AN ANTI-HBS VALUE OF 1000 IU/L WITH A DATA FLAG. THE SAMPLE WAS REPEATED TWICE ON (B)(6) 2024, RESULTING IN VALUES OF 1000 IU/L WITH A DATA FLAG AND < 350 IU/L WITH A DATA FLAG. THE SAMPLE WAS REPEATED ON A SECOND E801 ANALYZER AND THE SAME RESULTS WERE MEASURED. NO SPECIFIC VALUES WERE PROVIDED. THE CUSTOMER SENT TH
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19197508 ↗MalfunctionJan 24, 2024False Negative Result; False Negative Result
THERE WAS AN ALLEGATION OF QUESTIONABLE ELECSYS ANTI-HBS IMMUNOASSAY RESULTS FOR 1 PATIENT ON A COBAS E 801 ANALYTICAL UNIT. THIS MEDWATCH WILL COVER ANTI-HBS. REFER TO MEDWATCH WITH A1 PATIENT IDENTIFIER (B)(6) FOR INFORMATION ON THE HBSAG RESULTS. ON (B)(6) 2023, THE PATIENT HAD AN ANTI-HBS OF <3.5 MIU/ML, INTEPRETED AS NEGATIVE, AND AN HBSAG RESULT OF REACTIVE. THE INITIAL RESULTS WERE QUESTIONED WHICH PROMPTED A NEW SAMPLE TO BE COLLECTED FOR THE PATIENT. ON (B)(6) 2023, THE PATIENT HAD AN ANTI-HBS OF 136 MIU/ML, INTERPRETED AS POSITIVE, AND AN HBSAG RESULT OF NON-REACTIVE. THE SAMPLE WAS REPEATED AND THE RESULTS WERE CONFIRMED. ON (B)(6) 2023, THE PATIENT HAD ANOTHER SAMPLE COLLECTED AND THE ANTI-HBS RESULT WAS 173 MIU/ML, INTERPRETED AS POSITIVE, AND THE HBSAG RESULT WAS NON-REACTIVE. THE SAMPLE WAS REPEATED AND THE RESULTS WERE CONFIRMED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18571911 ↗
Other Test, hepatitis b (b core, be antigen, be antibody, b core igm) devices
- Elecsys HBsAg II 08814848190Roche Diagnostics GmbH · Test, hepatitis b (b core, be antigen, be antibody, b core igm)93 reports
- ARCHITECT 4P53-25Abbott Ireland Diagnostics · Test, hepatitis b (b core, be antigen, be antibody, b core igm)1 recall16 reports
- VITROS 6801925Ortho Clinical Diagnostics · Test, hepatitis b (b core, be antigen, be antibody, b core igm)1 recall15 reports
- ARCHITECT 1L82-27Abbott Ireland Diagnostics · Test, hepatitis b (b core, be antigen, be antibody, b core igm)1 recall4 reports
- VITROS 6801926Ortho Clinical Diagnostics · Test, hepatitis b (b core, be antigen, be antibody, b core igm)1 recall0 reports
- ARCHITECT 4P54-25Abbott Ireland Diagnostics · Test, hepatitis b (b core, be antigen, be antibody, b core igm)27 reports
- ADVIA Centaur® HBsII 10492138Siemens Healthcare Diagnostics Inc. · Test, Hepatitis B (B Core, Be Antigen, Be Antibody, B Core Igm)18 reports
- Atellica™ IM HBsII 10995604Siemens Healthcare Diagnostics Inc. · Test, hepatitis b (b core, be antigen, be antibody, b core igm)12 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page