M.U.S.T. Polyaxial Pedicle Screw 03.50.054Recalls & reported problems
Medacta International SA · Pedicle screw 8x40mm + Nut (1x) - Sterile · Class 2 · Implant
All models of M.U.S.T. Polyaxial Pedicle Screw (25)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07630030834417), received between Nov 22, 2017 and Jun 16, 2023 — classified as 3 injuries.
The most frequently reported specific device problem is “Device Issue” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device Issue1
- Failure to Osseointegrate1
- Loose or Intermittent Connection1
Patient problems
- Arthritis1
- Inadequate Osseointegration1
- Joint Disorder1
- Pain1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJun 16, 2023Failure to Osseointegrate; Failure to Osseointegrate
THE PATIENT HAD A PRIMARY SURGERY ON (B)(6) 2023, AND HAD A REVISION SURGERY ON (B)(6) 2023, DUE TO CAGES MIGRATION. ON (B)(6) 2023 SURGERY PERFORMED TO EXTEND THE CONSTRUCT FROM L3-L5 TO L3-S2AI. DURING THE SURGERY, ONE SCREW IN L5 WAS LOOSE AND THE CROSS-CONNECTOR IN L5 WAS FOUND WITH ONE HOOK LOOSE. THE CROSS-CONNECTOR WAS REMOVED AND REPLACED WITH A NEW ONE, WHILE THE TULIP OF THE SCREW WAS BLOCKED, THEREFORE THE HEAD ADJUSTER HAD TO BE USED TO REMOVE THE SCREW BECAUSE THE SCREWDRIVER CANNOT BE INSERTED IN THE HEAD OF THE SCREW. THE SURGERY WAS COMPLETED SUCCESSFULLY. DELAY TIME WAS 5MIN.
Patient problems: Inadequate Osseointegration
MAUDE report 17144075 ↗InjuryAug 11, 2020Loose or Intermittent Connection
SPINAL FIXTAION WAS PERFORMED AT L2-L5 FIRSTLY. THE SURGEON ENGAGED THE PEDICLE SCREW WITH THE SCREW DRIVER, BUT HE FELT THE ENGAGE STRENGTH OF THE PEDICLE SCREW AND THE SCREWDRIVER MIGHT BE WEAK. AFTER THE INSERTION OF THE PEDICLE SCREW AND THE ROD, THE SURGEON FELT THE LOOSENING OF THE PEDICLE SCREW AT THE LEFT SIDE OF THE L5, SO THE SURGEON REPLACED THE PEDICLE SCREW AND THE ROD AND PERFORMED THE ADDITIONAL SPINAL FIXTAION. MOREOVER WHEN THE SURGEON ENGAGED THE CROSS CONNECTOR, THE ARM OF THE CROSS CONNECTOR CONTACTED TO THE LAMINA. IN ORDER TO USE IT THE SURGEON PERFORMED ADDITIONAL LAMINA CUT. THE SURGEON DID NOT USE THE CROSS CONNECTOR BECAUSE THE SURGEON WOULD LIKE TO AVOID ADDITIONAL CUT. FINALLY, L2-S1 WAS FIXED. DUE TO THIS EVENT THE SURGERY WAS PROLONGED ABOUT 25 MINUTES. TOTAL SURGERY TIME WAS ABOUT 150MINS.
Patient problems: Joint Disorder
MAUDE report 10389668 ↗InjuryNov 22, 2017Device Issue; Device Issue
THE PATIENT HAD A PRIMARY FUSION OF L3-S1. THE PATIENT CAME IN COMPLAINING OF RIGHT LEG PAIN AND LOWER BACK PAIN. THE PATIENT PRESENTED WITH PSEUDO ARTHRITIS. THE SURGEON DETERMINED THAT THE SCREWS BACKED OUT. THE SURGEON REVISED ALL MEDACTA SCREWS AND RODS. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Arthritis; Pain
MAUDE report 7052116 ↗
Other Appliance, Fixation, Spinal Interlaminal devices
- EXPEDIUM 179702000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL439 reports
- EXPEDIUM VERSE 199721001Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL227 reports
- XIA 3 48230000Stryker Corporation · APPLIANCE, FIXATION, SPINAL INTERLAMINAL193 reports
- VIPER 186715000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL1 death167 reports
- NA 04.614.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL80 reports
- NA 04.615.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- EXPEDIUM VIPER 196789480Depuy Spine, LLC · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- Arsenal Deformity Spinal Fixation System 47127Alphatec Spine, Inc. · APPLIANCE, FIXATION, SPINAL INTERLAMINAL66 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page