The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07630030895982), received between Jun 25, 2019 and Jan 17, 2023 — classified as 6 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available4
- Adverse Event Without Identified Device or Use Problem1
- Insufficient Device Problem Information1
Patient problems
- Unspecified Infection3
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Implant Pain1
- Pain1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryJan 17, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT CAME IN FOR A POST-OP APPOINTMENT AND IT WAS OBSERVED THAT PATIENT'S FEMORAL COMPONENT WOULD IMPINGE UPON CEMENT IN FLEXION. AT ABOUT 8 MONTHS POST PRIMARY THE SURGEON REMOVED THE POLY, CLEARED OUT CEMENT POSTERIORLY AND PUT IN A NEW POLY SUCCESSFULLY.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 16181553 ↗InjuryDec 28, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
REVISION SURGERY AT ABOUT 1 MONTH POST PRIMARY DUE TO PAIN. THE SURGEON COMMENTED THAT A SLIGHT VARUS OF THE TIBIAL BASEPLATE COULD BE THE CAUSE OF THE PAIN. THERE WAS NO LOOSENING/MOBILIZATION.
Patient problems: Implant Pain
MAUDE report 16061013 ↗InjuryApr 20, 2022Appropriate Device Problem Term/Code Not Available
REVISION SURGERY WAS PERFORMED DUE TO PAIN AFTER ABOUT 1 YEAR FROM THE PRIMARY SURGERY. ONLY THE LINER WAS REPLACED, THICKNESS HAS NOT BEEN CHANGED, DUE TO YELLOW BONE AND SOFT TISSUES DISCOLORATION. SUSPECT OF INFECTION BUT NOT CONFIRMED. THE LINER WAS A LITTLE BIT DENTED.
Patient problems: Pain
MAUDE report 14158287 ↗InjuryJul 8, 2021Appropriate Device Problem Term/Code Not Available
1 MONTH AFTER THE PRIMARY SURGERY THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE POLY AND THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Unspecified Infection
MAUDE report 12133638 ↗InjuryDec 12, 2020Appropriate Device Problem Term/Code Not Available
THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED AN I&D AND POLY SWAP 1 MONTH AFTER PRIMARY. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Unspecified Infection
MAUDE report 10996068 ↗InjuryJun 25, 2019Appropriate Device Problem Term/Code Not Available
ABOUT 2 YEARS AFTER PRIMARY THE SURGEON REVISED THE PATIENT FOR A INFECTION. THE SURGEON PERFORMED AN I&D AND LINER SWAP AND THE SURGERY WAS COMPLETED SUCCESSFULLY. THE PATHOGEN IS UNKNOWN.
Patient problems: Unspecified Infection
MAUDE report 8731007 ↗
Other Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page