Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630345705228), received between Nov 10, 2025 and Nov 10, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Implant subsidence” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Implant subsidence1
- Loosening of Implant Not Related to Bone-Ingrowth1
- Malposition of Device1
Patient problems
- Aseptic loosening1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 10, 2025Malposition of Device; Loosening of Implant Not Related to Bone-Ingrowth; Implant subsidence; Malposition of Device; Loosening of Implant Not Related to Bone-Ingrowth; Implant subsidence
AT ABOUT 2 WEEKS AFTER THE PRIMARY, THE PATIENTCAME IN REPORTING PAIN DUE TO A LOOSE AND SUBSIDED BASEPLATE AND THE CAUSE IS UNKNOWN. THE PATIENT DIDN & RSQUO; T COMPLAIN ANY FALLS BUT MENTIONED POSSIBLY OVERDOING ACTIVITY, FEELING WELL FOR THE FIRST TIME IN YEARS. THE SURGEON FOUND THE BASEPLATE/POLYETHYLENE GROSSLY LOOSE AND SUSPECTED A CEMENT ISSUE, AS THE INITIAL FIT HAD BEEN EXCELLENT. THE SURGEON REVISED ALL COMPONENTS. THE SURGERY WAS COMPLETED SUCCESSFULLY. ADDITIONAL NOTE FOR CLINICAL INTERNAL ANALYSES: THE X-RAY SHOWS THAT THE FEMORAL COMPONENT APPEARS TO BE POSITIONED IN FLEXION, WITH AN IMPERFECT FIT TO THE FEMORAL BONE; THEREFORETHE LEVEL 2 CHANGE THE CLASSIFICATION FROM ASSOCIATED COMPONENT TO MALPOSITIONING.
Patient problems: Aseptic loosening
MAUDE report 23510665 ↗
FDA clearance and classification
Cleared through 510(k) K213071 on Nov 16, 2021 (decision: Substantially Equivalent). Submitted by Medacta International S.A. as “MOTOTM Partial Knee & MOTO PFJ Systems Extension”. The FDA review took 54 days. FDA record ↗
The FDA regulates product code HSX (prosthesis, knee, femorotibial, non-constrained, cemented, metal/polymer) under 21 CFR 888.3520 as a Class II device. 21 CFR 888.3520 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the MOTO Partial Knee System 02.18.702RM
Has the MOTO Partial Knee System 02.18.702RM been recalled?
No FDA recall record in our data names this exact device identifier (DI 07630345705228), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the MOTO Partial Knee System 02.18.702RM?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Nov 10, 2025. That report lists device problems “Implant subsidence” (1), “Loosening of Implant Not Related to Bone-Ingrowth” (1) and “Malposition of Device” (1); patient problem “Aseptic loosening” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the MOTO Partial Knee System 02.18.702RM?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the MOTO Partial Knee System 02.18.702RM FDA approved?
It was cleared through 510(k) K213071 on Nov 16, 2021. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the MOTO Partial Knee System 02.18.702RM MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the MOTO Partial Knee System 02.18.702RM, and is it still sold?
The FDA's device database lists Medacta International SA as the company responsible for it (brand MOTO Partial Knee System, model 02.18.702RM). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page