MOTO Partial Knee System 02.18.EIF6.08.LMRecalls & reported problems
Medacta International SA · E-CROSS tibial insert fix S6 LM - 8mm · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07630345712103), received between Jul 25, 2023 and May 22, 2026 — classified as 4 injuries.
The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Device Appears to Trigger Rejection3
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Medical device site infection4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryMay 22, 2026Device Appears to Trigger Rejection
REVISION SURGERY DUE TO INFECTION AFTER ABOUT 1 MONTH FROM PRIMARY. THE PATIENT HAD PRIMARY LEFT KNEE SURGERY ON (B)(6) 2026. ON (B)(6) 2026, THE PATIENT CAME IN DUE TO SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE MOTO S6 LM - H8 INSERT TO A SAME SIZE INSERT (MDR 2026-00482). PRESENTLY, ON (B)(6) 2026, THE PATIENT CAME IN DUE TO CONTINUED SIGNS OF INFECTION AND THE PATHOGEN IS UNKNOWN. THE SURGEON REMOVED THE MOTO FEMORAL COMPONENT AND MOTO TIBIAL TRAY FROM THE PRIMARY SURGERY AND REMOVED THE MOTO INSERT FROM THE FIRST REVISION AND IMPLANTED ANTIBIOTIC SPACERS TO TREAT THE INFECTION.
Patient problems: Medical device site infection
MAUDE report 25253485 ↗InjuryMay 20, 2026Adverse Event Without Identified Device or Use Problem
REVISION SURGERY AFTER 22 DAYS FROM THE PRIMARY SURGERY DUE TO SIGNS OF INFECTION, AND THE PATHOGEN IS UNKNOWN. THE SURGEON PERFORMED A WASHOUT AND REVISED THE INSERT TO THE SAME SIZE INSERT. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Medical device site infection
MAUDE report 25230410 ↗InjuryApr 14, 2026Device Appears to Trigger Rejection
THE PATIENT HAD A KNEE INFECTION AND THE PATHOGEN IS UNKNOWN. AT ABOUT 1 MONTH FROM PRIAMRY THE SURGEON PERFORMED A WASHOUT AND REVISED INSERT IMPLANTING ONE OF THE SAME SIZE. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Medical device site infection
MAUDE report 24871684 ↗InjuryJul 25, 2023Device Appears to Trigger Rejection; Device Appears to Trigger Rejection
THE PATIENT CAME IN DUE TO SIGNS OF AN INFECTION AND THE PATHOGEN IS UNKNOWN. ABOUT 1 MONTH AFTER THE PRIMARY SURGERY, THE SURGEON PERFORMED A WASHOUT AND REVISED THE LINER. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Medical device site infection
MAUDE report 17387500 ↗
FDA clearance and classification
Cleared through 510(k) K213071 on Nov 16, 2021 (decision: Substantially Equivalent). Submitted by Medacta International S.A. as “MOTOTM Partial Knee & MOTO PFJ Systems Extension”. The FDA review took 54 days. FDA record ↗
The FDA regulates product code HSX (prosthesis, knee, femorotibial, non-constrained, cemented, metal/polymer) under 21 CFR 888.3520 as a Class II device. 21 CFR 888.3520 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the MOTO Partial Knee System 02.18.EIF6.08.LM
Has the MOTO Partial Knee System 02.18.EIF6.08.LM been recalled?
No FDA recall record in our data names this exact device identifier (DI 07630345712103), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the MOTO Partial Knee System 02.18.EIF6.08.LM?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Jul 25, 2023 and May 22, 2026. In those reports, the most common specific device problem is “Device Appears to Trigger Rejection” (3); the most common patient problem is “Medical device site infection” (4). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the MOTO Partial Knee System 02.18.EIF6.08.LM?
None of the reports are classified as deaths, 4 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the MOTO Partial Knee System 02.18.EIF6.08.LM FDA approved?
It was cleared through 510(k) K213071 on Nov 16, 2021. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the MOTO Partial Knee System 02.18.EIF6.08.LM MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the MOTO Partial Knee System 02.18.EIF6.08.LM, and is it still sold?
The FDA's device database lists Medacta International SA as the company responsible for it (brand MOTO Partial Knee System, model 02.18.EIF6.08.LM). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer devices
- LinkSymphoKnee 880-307/21WALDEMAR LINK GmbH & Co. KG · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls2 reports
- Scorpio 73-3710Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls1 report
- Scorpio 73-3110Howmedica Osteonics Corp. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER2 recalls0 reports
- Arthrex® AR-503-TTTEArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall14 reports
- Arthrex® AR-503-TTTJArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall9 reports
- ENGAGE 1-10011-300Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- Arthrex® AR-503-TTTGArthrex, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall7 reports
- ENGAGE 1-10003-400Smith & Nephew, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, NON-CONSTRAINED, CEMENTED, METAL/POLYMER1 recall6 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page