RHA® Redensity RHA® Redensity US 1ml Schott/2 aig. Terumo TW30G1/2 (REF 940056/02)Recalls & reported problems

Teoxane SA · "One box of RHA® Redensity contains two blisters and one instruction for use. Each blister contains a 1mL prefilled syringe and two needles (30G 1/2). Box Packaging (ID 07640173234180) is defined as unit of sales and identified with a serial number." · Class 3 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07640173234197), received between Mar 30, 2026 and Mar 30, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Hypersensitivity/Allergic reaction1
  • Swelling/ Edema1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 30, 2026Adverse Event Without Identified Device or Use Problem

    ALLERGIC REACTION [TYPE I HYPERSENSITIVITY] ([FACE OEDEMA]) RHA REDENSITY TO EACH OF 4 LIP QUADRANTS/LIPS THEMSELF, SUPERFICIAL NFL LINES [OFF LABEL USE]. CASE NARRATIVE: ON 03-MAR-2026, PRIMEVIGILANCE NOTIFIED TEOXANE GENEVA OF AN ADVERSE EVENT FROM THE UNITED STATES. ACCORDING TO THE INFORMATION RECEIVED FROM THE INJECTOR, A PATIENT WAS INJECTED ON (B)(6) 2026 WITH RHA REDENSITY AND THE 30G NEEDLES PROVIDED IN THE BOX: IN THE PERIORAL LINES (ABOVE THE UPPER LIP). IN THE LIPS (0.05 - 1 ML TO EACH OF 4 LIP QUADRANTS). IN THE NASOLABIAL FOLD LINES SUPERFICIALLY. THE PATIENT HAD A HISTORY OF ALLERGIES INCLUDING: DUST MITES, BALSAM OF PERU, FORMALDEHYDE, RUBBER ACCELERATORS, LIMONENE, LINALOOL, AND MINOXIDIL. THE PATIENT HAD HISTORY OF OTHER AESTHETIC TREATMENTS: HYDRAFACIALS, IPL, HOLLYWOOD SPECTRA LASER ALTHOUGH NO OTHER FILLER HISTORY. SHE HAS ALSO HAD A FACE LIFT PRIOR TO THE INJECTION. PATIENT'S CONCOMITANT MEDICATION INCLUDED LISINOPRIL, HYDROCHLOROTHIAZID (HCTZ), LIPITOR, PROBIOTICS, AND VITAMIN D. ON (B)(6) 2026, IMMEDIATELY AFTER TREATMENT THE PATIENT HAD A NORMAL POST-PROCEDURE PERI-ORAL SWELLING AND WAS ADVISED TO ICE ON AND OFF THROUGHOUT THE DAY. SHE HAD NO BRUISING, REDN

    Patient problems: Hypersensitivity/Allergic reaction; Swelling/ Edema

    MAUDE report 24727969 ↗

Other Implant, Dermal, For Aesthetic Use devices

All Implant, Dermal, For Aesthetic Use devices →