Neo Pedicle Screw System SC-80-50-PERecalls & reported problems

Neo Medical SA · Pedicle screw kit 2x(Ø8.0 x 50mm) · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07640177820693), received between Aug 9, 2024 and Aug 9, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • Implant Pain1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 9, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    EVENT DESCRIPTION: REVISION SURGERY PERFORMED ON (B)(6) 2024 AFTER 10 MONTHS FROM INITIAL SURGERY DUE TO PAIN AND DISCONNECTED OF THE SCREW HEAD FROM THE SCREW SHAFT ON THE LEVEL L5 ON BOTH SIDES. A SECOND SURGERY TOOK PLACE AFTER THE REVISION SURGERY TO IMPLANT AN INTERBODY FUSION CAGE ON L4 V INITIAL SURGERY PERFORMED ON (B)(6) 2023 WITH MONOAXIAL SCREWS SC-80-50-PE (ON LEVEL L4 SC-80-55-PE (2021046031) AND RD-00-90-PB (2020035136)). COMPLAINT INVESTIGATION: THE X-RAY AFTER THE FIRST SURGERY IN (B)(6) 2023 LOOKS FINE (NO SCREW BREAKAGE OR DISCONNECTION). THE PATIENT WAS SUPPOSED TO GET A FOLLOW-UP VISIT SCHEDULED AT 6 WEEKS FOR X-RAY CONTROL BUT HE DID NOT SHOW UP. AT THAT TIME THE SURGEON ALSO PLANNED A SECOND SURGERY TO ADD THE ANTERIOR SUPPORT SURGERY (ADDING A CAGE). ONLY AFTER 10 MONTHS THE PATIENT CAME TO THE HOSPITAL WITH PAIN AND THE PROBLEM LEADING TO A THE FIRST REVISION SURGERY. NO FUSION COULD BE SEEN AT THE 10 MONTH X-RAY. IN CASE A CAGE IS NOT PLACED A FUSION WILL NOT OCCUR. AS STATED IN IFU FOR NEO PEDICLE SCREW SYSTEM: "THE NEO PEDICLE SCREW SYSTEM¿ IS INTENDED TO HELP PROVIDE IMMOBILIZATION, CORRECTION AND STABILIZATION OF SPINAL SEGMENTS AS AN ADJUNCT TO FUSION

    Patient problems: Implant Pain

    MAUDE report 19949667 ↗

Other Thoracolumbosacral Pedicle Screw System devices

All Thoracolumbosacral Pedicle Screw System devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page