Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033178110044), received between Mar 4, 2022 and Mar 4, 2022 — classified as 1 injury.

The most frequently reported specific device problem is “Chemical Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Chemical Problem1

Patient problems

  • Bradycardia1
  • Hemolysis1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 4, 2022Chemical Problem; Chemical Problem

    SORIN GROUP (B)(4) HAS RECEIVED A REPORT THAT, ON (B)(6) 2022, DURING AN EMERGENCY PROCEDURE, SUDDEN HYPOTENSION OCCURRED. MEDICAL TEAM ADMINISTER BLOOD COLLECTED FROM THE CELL SAVER TO THE PATIENT. ACCORDING TO INFORMATION, DURING THE ADMINISTRATION, BLOOD WAS DARK COLOR AND ADMINISTRATION WAS INTERRUPTED. AT THIS TIME, PATIENT SHOWED BRADYCARDIA AND MEDICAL TEAM ELECTED TO ADMINISTER ATROPINE TO THE PATIENT AND TO PERFORM BLOOD GASES ANALYSIS. BLOOD GASES ANALYSIS SHOWED HIGH SERUM POTASSIUM (6.7 MMOL/L) THAT MEDICAL TEAM ELECTED TO TREAT BY INJECTION OF CALCIUM CHLORIDE AND INSULIN/GLUCOSE, CONTROL AT 4 MMOL/L. THE MEDICAL TEAM SENT TO ANALYSIS THE DARK BLOOD AND HIGH POTASSIUM (22.5 MMOL/L) AND SODIUM (14 MMOL/L) WERE FOUND. ACCORDING TO CUSTOMER, HYPERKALEMIA ON POTENTIAL HEMOLYSIS OF THE CONTENT OF CELL SAVER HAS OCCURRED. THE PATIENT HAS BEEN TRANSFERRED TO RESUSCITATION/INTENSIVE CARE FOR MONITORING AND IS NOW STABLE. DISPOSABLE DEVICE HAS BEEN SAVED BY THE CUSTOMER.

    Patient problems: Bradycardia; Hemolysis

    MAUDE report 13665461 ↗

FDA clearance and classification

Cleared through 510(k) K101586 on Oct 5, 2010 (decision: Substantially Equivalent). Submitted by Sorin Group Italia S.R.L. as “Xtra Autotransfusion System”. The FDA review took 120 days. FDA record ↗

The FDA regulates product code CAC (apparatus, autotransfusion) under 21 CFR 868.5830 as a Class II device. 21 CFR 868.5830 ↗

The FDA lists this type of device as life-sustaining or life-supporting.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the XTRA BOWL SET X/225

Has the XTRA BOWL SET X/225 been recalled?

No FDA recall record in our data names this exact device identifier (DI 08033178110044), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the XTRA BOWL SET X/225?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 4, 2022. That report lists device problem “Chemical Problem” (1); patient problems “Bradycardia” (1) and “Hemolysis” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the XTRA BOWL SET X/225?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the XTRA BOWL SET X/225 FDA approved?

It was cleared through 510(k) K101586 on Oct 5, 2010. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the XTRA BOWL SET X/225, and is it still sold?

The FDA's device database lists Sorin Group Italia Srl as the company responsible for it (brand XTRA, model BOWL SET X/225). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.