XTRA PROCEDURE SET BX/225Recalls & reported problems

Sorin Group Italia Srl · Class 2

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08033178110808), received between Jul 6, 2016 and Jul 4, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Operates Differently Than Expected1
  • Disconnection1
  • Fracture1

Patient problems

  • No Consequences Or Impact To Patient2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 4, 2024Fracture; Fracture

    SORIN GROUP ITALY RECEIVED A REPORT THAT THE UPPER PORTION OF AN XTRA BOWL COMING SEPARATED FROM THE BOTTOM PORTION THAT SITS IN THE CENTRIFUGE WELL AND AS A CONSEQUENCE THERE WAS A SIGNIFICANT AMOUNT OF FLUID LOSS. BLOOD LEAKED OUT THE BOWL AND CENTRIFUGE AND THE USER WAS CONTAMINATED. THE ISSUE OCCURRED DURING PROCEDURE. THE BOWL PLATE WAS LEFT IN THE CENTRIFUGE WELL AND THE CUSTOMER HAD TO USE A SCREWDRIVER TO PRY THE DISPOSABLE BASE FROM THE CENTRIFUGE. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19674951 ↗
  • MalfunctionApr 5, 2017Disconnection; Disconnection

    SORIN GROUP (B)(6) RECEIVED A REPORT THAT THE BLUE TUBING FROM THE XTRA PROCEDURE SET DISCONNECTED FROM THE RESERVOIR DURING A CASE AND BLOOD SPILLED ON FLOOR AND DOCTOR. THE TUBING WAS RECONNECTED AND THE PROCEDURE WAS COMPLETED WITHOUT FURTHER ISSUE. THERE WAS NO PATIENT INJURY, AND NO INJURY WAS REPORTED FOR THE DOCTOR.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6459594 ↗
  • Jul 6, 2016Device Operates Differently Than Expected; Device Operates Differently Than Expected

    SORIN GROUP (B)(4) RECEIVED A USER MEDWATCH REPORT (MW5062325) ON JUNE 13, 2016 STATING THAT THE XTRA BOWL FOR THE XTRA AUTOTRANSFUSION SYSTEM DID NOT EMPTY PROPERLY DURING A PROCEDURE. THE BOWL WOULD PARTIALLY EMPTY AND THEN STOP. THE BOWL WAS CHANGED TO ANOTHER FROM THE SAME LOT AND THE SAME ISSUE OCCURRED. A THIRD DIFFERENTLY SIZED BOWL FROM A DIFFERENT LOT WAS SET UP AND WORKED PROPERLY. THE CUSTOMER REPORTED THAT 2000ML OF SALVAGED BLOOD WAS DISCARDED DUE TO THE ISSUE. THERE WAS NO REPORT OF PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 5774159 ↗

Other APPARATUS, AUTOTRANSFUSION devices