TEMA Elbow 1552.14.020Recalls & reported problems
Limacorporate SPA · Ulnar Body large left · Class 2 · Implant
All models of TEMA Elbow (15)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08033390126441), received between Jul 26, 2024 and Jul 26, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Patient Device Interaction Problem2
Patient problems
- Implant Pain1
- Medical device site infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 26, 2024Patient Device Interaction Problem; Patient Device Interaction Problem
AFTER AN IRRIGATION AND DEBRIDEMENT PROCEDURE PERFORMED ON (B)(6) 2024, THE FOLLOW-UP VISIT ON (B)(6) 2024 HIGHLIGHTED PERSISTENT LUCENCY ABOUT THE PROXIMAL PROSTHESIS, POSSIBLE SYMPTOM OF LOOSENING (INFECTION NOT EXCLUDED). THE NEXT SURGERY WAS PERFORMED ON (B)(6) 2024, DUE TO INFECTION. THE FOLLOWING COMPONENTS WERE REMOVED AND REPLACED WITH THIRD-PARTY COMPONENTS AND AN ANTIBIOTIC SPACER: SMR MODULAR AUGMENT H.20 MM (PART CODE 1314.15.020, LOT NUMBER 2101626, STERILIZATION NUMBER (B)(4). ULNAR BODY LARGE LEFT + SCREW (PART CODE 1552.14.020, LOT NUMBER 2310984, STERILIZATION NUMBER (B)(4). ULNAR LINER - LARGE LEFT TEMA (PART CODE 1560.50.020, LOT NUMBER 18AT1Q3, STERILIZATION NUMBER (B)(4). AXLE #LARGE (PART CODE 1590.15.020, LOT NUMBER 2227696, STERILIZATION NUMBER (B)(4). CMD 22-1325 ULNAR AUGMENT (PART CODE 9618.14.0Q3, LOT NUMBER 2313059, STERILIZATION NUMBER (B)(4). CMD 22-1325 ULNAR FLANGE (PART CODE 9618.14.0Q4, LOT NUMBER 2313041, STERILIZATION NUMBER (B)(4). CMD 22-1325 HUMERAL STEM (PART CODE 9618.15.07U, LOT NUMBER 2313187, STERILIZATION NUMBER (B)(4). CMD 22-1325 HUMERAL IMPLANT (PART CODE 9618.15.07V, LOT NUMBER 2313191, STERILIZATION NUMBER (B)(4). CMD 22-1325 ULNAR
Patient problems: Medical device site infection
MAUDE report 19838074 ↗InjuryJul 26, 2024Patient Device Interaction Problem; Patient Device Interaction Problem
AFTER A REVISION SURGERY, DURING THE FOLLOW-UP VISIT PERFORMED ON (B)(6) 2024, THE PATIENT REPORTED INCREASING PAIN AND FLUID COLLECTION WAS NOTICED. THE SURGEON RECOMMENDED AN IRRIGATION AND DEBRIDEMENT PROCEDURE AND CULTURES. THEREFORE, THE NEXT REVISION SURGERY WAS PERFORMED ON (B)(6) 2024, DUE TO SUSPECTED INFECTION. A CEMENT PLATE MADE WITH ANTIMICROBIAL CEMENT WAS IMPLANTED. THE FOLLOWING COMPONENTS, ALREADY IMPLANTED, WERE LEFT IN SITU: SMR MODULAR AUGMENT H.20 MM (PART CODE: 1314.15.020, LOT NUMBER: 2101626, STERILIZATION NUMBER: 2200113). ULNAR BODY LARGE LEFT + SCREW (PART CODE: 1552.14.020, LOT NUMBER: 2310984, STERILIZATION NUMBER: 2300136). ULNAR LINER - LARGE LEFT TEMA (PART CODE: 1560.50.020, LOT NUMBER: 18AT1Q3, STERILIZATION NUMBER: 1900225). AXLE #LARGE (PART CODE: 1590.15.020, LOT NUMBER: 2227696, STERILIZATION NUMBER: 2300054). CMD 22-1325 ULNAR AUGMENT (PART CODE: 9618.14.0Q3, LOT NUMBER: 2313059, STERILIZATION NUMBER: 2300129). CMD 22-1325 ULNAR FLANGE (PART CODE: 9618.14.0Q4, LOT NUMBER: 2313041, STERILIZATION NUMBER: 2300129). CMD 22-1325 HUMERAL STEM (PART CODE: 9618.15.07U, LOT NUMBER: 2313187, STERILIZATION NUMBER: 2300125). CMD 22-1325 HUMERAL IMPLANT (P
Patient problems: Implant Pain
MAUDE report 19836320 ↗
Other Prosthesis, Elbow, Semi-Constrained, Cemented devices
- TEMA Elbow 1590.15.010Limacorporate SPA · Prosthesis, Elbow, Semi-Constrained, Cemented2 recalls3 reports
- TEMA Elbow 1590.15.020Limacorporate SPA · Prosthesis, Elbow, Semi-Constrained, Cemented1 recall1 report
- Latitude™ - Elbow DKY068Tornier, Inc. · PROSTHESIS, ELBOW, SEMI-CONSTRAINED, CEMENTED20 reports
- DURALOC 1241-46-526Depuy Orthopaedics, Inc. · PROSTHESIS, ELBOW, SEMI-CONSTRAINED, CEMENTED17 reports
- Latitude™ - Elbow DKY067Tornier, Inc. · PROSTHESIS, ELBOW, SEMI-CONSTRAINED, CEMENTED8 reports
- RHS - RADIAL PROSTHESIS DTJ302Tornier · PROSTHESIS, ELBOW, SEMI-CONSTRAINED, CEMENTED6 reports
- Latitude™ - Elbow DKY082Tornier, Inc. · PROSTHESIS, ELBOW, SEMI-CONSTRAINED, CEMENTED5 reports
- Latitude™ - Elbow DKY216Tornier, Inc. · PROSTHESIS, ELBOW, SEMI-CONSTRAINED, CEMENTED5 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page