Skip to content

SMR System 1308.15.154Recalls & reported problems

Limacorporate SPA · SMR System - Revision Stem Dia. 15 mm H. 150 mm · Class 2 · Implant

All models of SMR System (47)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033390271646), received between Nov 20, 2025 and Nov 20, 2025 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 20, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE COMPLAINT SOURCE REPORTED REVISION SURGERY PERFORMED ON (B)(6) 2025, WITH REMOVAL OF THE SMR CEMENTLESS STEM Ø15 MM, TOGETHER WITH THE GLENOSPHERE, LINER, AND HUMERAL BODY. THE REASON FOR THE REMOVAL OF THE STEM WAS THE NECESSITY TO IMPLANT A CUSTOM-MADE DEVICE (B)(4)). THE STANDARD DEVICE EXPLANTED ON (B)(6) 2025 - LISTED BELOW- WERE IMPLANTED ON (B)(6) 2023 TOGETHER WITH THE CUSTOM MADE (B)(4), WHICH WAS NECESSARY TO TREAT THE SHOULDER JOINT, GLENOID SIDE: · SMR CEMENTL. REV. STEM Ø15 MM (PRODUCT CODE:1308.15.154 - LOT:1517468) · SMR REVERSE FINNED HUMER. BODY (PRODUCT CODE: 1352.15.050, - LOT: 2305345- STER: (B)(4)) · SMR REVERSE HP LINER SHORT (PRODUCT CODE: 1362.09.010 - LOT:2119266) · SMR REVERSE HP GLENOSPH. 44 MM (PRODUCT CODE: 1374.50.440, LOT: 2108544 - STER: (B)(4)) ON THE SAME SIDE, THE PATIENT HAD AN ELBOW PROSTHESIS ALREADY IMPLANTED. SUCCESSIVELY, A CUSTOM-MADE DEVICE FOR ELBOW (B)(4) WAS DEEMED NECESSARY DUE TO "TRAUMATIC INJURY, RADIAL NERVE DAMAGE ON THE RIGHT SIDE AFTER HUMERAL FRACTURE, MISSING ELBOW AFTER ACCIDENT/INFECTION. SMR CEMENTLESS REVISION STEM SIZE Ø15MM H.150MM IN SITU." THE DEVELOPMENT OF (B)(4) BECAME NECESSARY BECAUSE THE SMR CEMENTLESS STEM Ø

    Patient problems: Insufficient Information

    MAUDE report 23605996 ↗

Other Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented devices

All Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page