SMR System 1377.50.005Recalls & reported problems
Limacorporate SPA · SMR System - Metal Back Liner Small-R · Class 2 · Implant
All models of SMR System (45)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08033390272674), received between Nov 8, 2024 and Mar 27, 2025 — classified as 3 injuries.
The most frequently reported specific device problem is “Degraded” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Degraded2
- Device Dislodged or Dislocated2
- Break1
- Material Integrity Problem1
- Unstable1
Patient problems
- Joint Dislocation2
- Metal Related Pathology1
- Muscle/Tendon Damage1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 27, 2025Degraded; Unstable; Device Dislodged or Dislocated; Degraded; Unstable; Device Dislodged or Dislocated
SHOULDER REVISION SURGERY PERFORMED ON (B)(6) 2025, DUE TO MULTIPLE COMPLICATIONS, INCLUDING SUSPECTED SUBSCAPULARIS FAILURE, IMPLANT INSTABILITY, POLYETHYLENE LOADING FAILURE, POLYETHYLENE DISRUPTION, AND BASEPLATE FAILURE. ACCORDING TO THE INFORMATION RECEIVED, THE PATIENT INITIALLY UNDERWENT PRIMARY SMR ANATOMIC SURGERY IN 2014. IN 2022, AFTER EXPERIENCING TWO FALLS, THE PATIENT CONSULTED THE SURGEON BUT INITIALLY CHOSE NOT TO UNDERGO REVISION SURGERY. THE FOLLOWING COMPONENTS WERE INVOLVED IN THIS CASE: SMR UNCEMENTED GLENOID #SMALL-R (CODE: 1375.20.005, LOT N. 1400108, STERILIZATION N. 1400054) LINER F. METAL BACK GLENOID SMALL-R (CODE: 1377.50.005, LOT N. 1313557, STERILIZATION N. 1300306). SOLD IN US. SMR HUMERAL HEAD Ø44 MM (PART CODE: 1322.09.440). NEUTRAL ADAPTOR TAPER STANDARD (PART CODE: 1330.15.270). SMR FINNED HUMERAL BODY (PART CODE: 1350.15.110). SMR CEMENTLESS FINNED STEM (PART CODE: 1304.15.170). BONE SCREW Ø6.5 H.20MM (PART CODE: 8420.15.010). BONE SCREW Ø6.5 H.25MM (PART CODE: 8420.15.020). PATIENT DETAILS: FEMALE, 85 YEARS OLD, BMI: 41.4 (PRE-OP, (B)(6) 2024). THE EXACT IMPLANTATION DATE OF THE ABOVE-LISTED COMPONENTS IN 2014 WAS NOT PROVIDED BY THE COMPLAINT S
Patient problems: Joint Dislocation
MAUDE report 21708943 ↗InjuryJan 7, 2025Material Integrity Problem; Material Integrity Problem
ON (B)(6) 2024, SHOULDER REVISION SURGERY FOR CONVERSION OF TSA (TOTAL SHOULDER ARTHROPLASTY) TO RSA (REVERSE SHOULDER ARTHROPLASTY) DUE TO WEAR OF THE LINER (PROD. CODE 1377.50.005, BATCH N. 15AT07U, STER.(B)(6)), CUFF TEAR AND METALLOSIS. PREVIOUS SURGERY PERFORMED ON (B)(6) 2016. TOGETHER WITH THE LINER THE FOLLOWING DEVICES WERE EXPLANTED: · SMR HUMERAL HEAD Ø52 MM (PRODUCT CODE: 1322.09.520, BATCH N. 1500216, STER.(B)(6)) - SOLD IN US. · SMR FINNED HUMERAL BODY (PRODUCT CODE: 1350.15.110, BATCH N. UNKNOWN) - SOLD IN US . PATIENT IS MALE, 74 AGE, HEIGHT 169 CM, WEIGHT 85 KG, VERY ACTIVE.
Patient problems: Metal Related Pathology; Muscle/Tendon Damage
MAUDE report 21091073 ↗InjuryNov 8, 2024Break; Degraded; Device Dislodged or Dislocated; Break; Degraded; Device Dislodged or Dislocated
SHOULDER REVISION SURGERY OCCURRED ON (B)(6) 2024, DUE TO SUCCESSIVELY INCREASING DISCOMFORT IN THE LAST TWO YEARS WITH MECHANICAL SYMPTOMS. COMPLAINT SOURCE REPORTED THAT DURING REVISION SURGERY LINER F. MET.BACK GLEN.SMALL-R (PRODUCT CODE: 1377.50.005, LOT. 17AT24T - STER. (B)(4)) RESULTED LUXATED WITH BROKEN PEGS AND PARTS OF THE BASE PLATE WERE WORN DOWN. THE HEAD OF THE TOP SCREW WAS ALMOST COMPLETELY GONE. PRONOUNCED METALLOSIS AND THE MASSIVE METALLOSIS WAS SUBCOMPLETELY CLEANED. THE BOTTOM SCREW WAS VERY TIGHT BUT COULD BE UNSCREWED IN ITS ENTIRETY WITHOUT DEFORMATION. THE HEAD OF THE TOP SCREW WAS RUNDOWN AND PENETRATES THE UPPER HOLE OF THE STANDARD PLATE. THE BASEPLATE WAS CHISELED, AND THE TOP SCREW WAS UNSCREWED. THE POSSIBILITY OF BEING ABLE TO IMPLANT A 360 WAS EVALUATED, BUT WHEN TRYING TO PLACE THE GLENOSPHERE THE OPERATOR NOTICED THAT THE UPPER SCREW HAD PENETRATED THE CORTEX, AND THE CONSTRUCTION WAS LOOSE. THE UPPER SCREW WAS REMOVED, AND A CUSTOM GLENOID METAL BACK WAS REQUESTED TO LIMACORPORATE. DEVICES REPORTED BELOW WERE IMPLANTED DURING PREVIOUS SURGERY PERFORMED ON (B)(6) 2018, DUE TO MODERATE GLENOHUMERAL OSTEOARTHRITIS. · LINER F. MET.BACK GLEN.SMALL-R (
Patient problems: Joint Dislocation
MAUDE report 20641114 ↗
FDA clearance and classification
Cleared through 510(k) K113254 on Feb 24, 2012 (decision: Substantially Equivalent). Submitted by Lima Corporate S.P.A. as “Smr Modular Glenoid-Metal-Back Smr Modular Glenoid-Liner Smr Modular Glenoid-Bone Screws”. The FDA review took 113 days. FDA record ↗
The FDA regulates product code KWS (prosthesis, shoulder, semi-constrained, metal/polymer cemented) under 21 CFR 888.3660 as a Class II device. 21 CFR 888.3660 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the SMR System 1377.50.005
Has the SMR System 1377.50.005 been recalled?
No FDA recall record in our data names this exact device identifier (DI 08033390272674), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the SMR System 1377.50.005?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Nov 8, 2024 and Mar 27, 2025. In those reports, the most common specific device problems are “Degraded” (2), “Device Dislodged or Dislocated” (2) and “Break” (1); the most common patient problems are “Joint Dislocation” (2), “Metal Related Pathology” (1) and “Muscle/Tendon Damage” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SMR System 1377.50.005?
None of the reports are classified as deaths, 3 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SMR System 1377.50.005 FDA approved?
It was cleared through 510(k) K113254 on Feb 24, 2012. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the SMR System 1377.50.005 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the SMR System 1377.50.005, and is it still sold?
The FDA's device database lists Limacorporate SPA as the company responsible for it (brand SMR System, model 1377.50.005). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented devices
- DJO SURGICAL 508-32-204Encore Medical, L.P. · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 recall547 reports
- Comprehensive Reverse Shoulder 010000589Biomet Orthopedics, LLC · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED1 recall135 reports
- DELTA XTEND 130738203Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED175 reports
- DJO SURGICAL 509-00-432Encore Medical, L.P. · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented1 recall117 reports
- Alliance® SBGL3007Zimmer, Inc. · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED158 reports
- DELTA XTEND 130760138Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED146 reports
- DELTA XTEND 130790030Depuy (Ireland) · PROSTHESIS, SHOULDER, SEMI-CONSTRAINED, METAL/POLYMER CEMENTED132 reports
- DJO SURGICAL 509-00-436Encore Medical, L.P. · Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented125 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page