Starter™ Guidewire M001491181Recalls & reported problems

Lake Region Medical Limited · "J" Curved Fixed Core Guidewire · Class 2

All models of Starter Guidewire (12)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 08714729201304), received between Nov 6, 2020 and Nov 17, 2024 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Material Integrity Problem” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem4
  • Fracture3
  • Material Deformation3

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • Insufficient Information1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 17, 2024Fracture; Fracture

    EVENT DESCRIPTION: ECN EVENT DESCRIPTION: THE HEAD OF THE HEMODYNAMICS SERVICE REPORTS THAT WHEN THE PRODUCT WAS ROTATED TO THE TABLE FOR PREPARATION, THE TIP OF THE GUIDE WAS FRACTURED. WHAT TROUBLESHOOTING STEPS, IF ANY, RESOLVED THE ISSUE?: THE PROBLEM WAS SOLVED BY USING ANOTHER GUIDE OF THE SAME SIZE. WHAT IS THE NEXT COURSE OF ACTION?: REPLENISH THE PRODUCT PATIENT PRESENT AT TIME OF EVENT?: YES, PATIENT COMPLICATIONS: NO PATIENT COMPLICATIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20702653 ↗
  • MalfunctionFeb 2, 2023Fracture; Fracture

    EVENT DESCRIPTION: IT WAS REPORTED THAT: DIFFICULT REMOVAL OF THE GUIDEWIRE, WHICH RESULTED IN THE SEVERING OF THE GUIDEWIRE DURING REMOVAL. DURING CHECK-UP POST-PROCEDURE, THE REST OF THE GUIDEWIRE WAS POSITIONED DISTALLY TO THE IN-PLACE DRAIN. ACTIONS TAKEN IN THE HEALTHCARE FACILITY FOR PATIENT MANAGEMENT: THE DRAIN AND THE REST OF THE GUIDEWIRE HAVE BEEN REMOVED FROM THE PATIENT. WHEN REMOVING THE DRAIN: WE HAD TO CONTROL THE REMOVAL OF THE REST OF THE GUIDEWIRE. THE DEVICE WAS NOT CONSERVED.EVENT DATE: (B)(6).

    Patient problems: Insufficient Information

    MAUDE report 16282942 ↗
  • MalfunctionSep 29, 2021Fracture; Fracture

    PER EMAIL, IT WAS REPORTED THAT: STARTER WIRE LOOKS DEFORMED BEFORE USE. HERE IS SOME ADDITIONAL INFORMATION ON THE GUIDEWIRE. 05AUG2021 JLC: RESPONSE RECEIVED FROM GAYATHRY N VADIVAL ON 02AUG2021 WHAT WAS THE ANATOMY LOCATION THAT THE PHYSICIAN WAS WORKING ON? LEFT MAIN TO LAD . PLEASE PROVIDE LESION DETAILS: % STENOSIS? LEFT MAIN 50%, LAD 70%. CALCIFICATION? (NOT CALCIFIED, MILD, MODERATE, SEVERE). CONCENTRIC CALCIUM IN LEFT MAIN, INTIMAL CALCIFICATION AT LAD. TORTUOSITY? (NOT TORTUOUS, MILD, MODERATE, SEVERE). NOT STATED . WHEN IS THE EXPECTED DATE THIS DEVICE WILL BE RETURNED? BY THIS MONTH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12545507 ↗
  • MalfunctionNov 6, 2020Material Deformation; Material Integrity Problem; Material Deformation; Material Integrity Problem

    UNUSABLE, KINKED GUIDEWIRE. THE WARD DOCTOR NOTICED THE PROBLEM WHEN INSERTING THE GUIDE. THERE WAS A HITCH, IT WAS NOT GOING THROUGH. THE GUIDEWIRE WOULD HAVE BROKEN AT THE "J" SHAPE EXTREMITY LEVEL. THIS IS A RECURRING PROBLEM, THIS IS THE 4TH OCCURRENCE, ALL GUIDEWIRES FROM THE SAME BATCH. NOTED CONSEQUENCES: THE PROCEDURE TIME WAS LENGTHENED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10799798 ↗
  • MalfunctionNov 6, 2020Material Deformation; Material Integrity Problem; Material Deformation; Material Integrity Problem

    UNUSABLE, KINKED GUIDEWIRE. THE WARD DOCTOR NOTICED THE PROBLEM WHEN INSERTING THE GUIDE. THERE WAS A HITCH, IT WAS NOT GOING THROUGH. THE GUIDEWIRE WOULD HAVE BROKEN AT THE "J" SHAPE EXTREMITY LEVEL. THIS IS A RECURRING PROBLEM, THIS IS THE 4TH OCCURRENCE, ALL GUIDEWIRES FROM THE SAME BATCH. NOTED CONSEQUENCES: THE PROCEDURE TIME WAS LENGTHENED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10799797 ↗
  • MalfunctionNov 6, 2020Material Integrity Problem; Material Integrity Problem

    UNUSABLE, KINKED GUIDEWIRE. THE WARD DOCTOR NOTICED THE PROBLEM WHEN INSERTING THE GUIDE. THERE WAS A HITCH, IT WAS NOT GOING THROUGH. THE GUIDEWIRE WOULD HAVE BROKEN AT THE "J" SHAPE EXTREMITY LEVEL. THIS IS A RECURRING PROBLEM, THIS IS THE 4TH OCCURRENCE, ALL GUIDEWIRES FROM THE SAME BATCH. NOTED CONSEQUENCES: THE PROCEDURE TIME WAS LENGTHENED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10799796 ↗
  • MalfunctionNov 6, 2020Material Deformation; Material Integrity Problem; Material Deformation; Material Integrity Problem

    UNUSABLE, KINKED GUIDEWIRE. THE WARD DOCTOR NOTICED THE PROBLEM WHEN INSERTING THE GUIDE. THERE WAS A HITCH, IT WAS NOT GOING THROUGH. THE GUIDEWIRE WOULD HAVE BROKEN AT THE "J" SHAPE EXTREMITY LEVEL. THIS IS A RECURRING PROBLEM, THIS IS THE 4TH OCCURRENCE, ALL GUIDEWIRES FROM THE SAME BATCH. NOTED CONSEQUENCES: THE PROCEDURE TIME WAS LENGTHENED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10799795 ↗

Other Wire, Guide, Catheter devices

All Wire, Guide, Catheter devices →