PT Graphix™ H74914903011Recalls & reported problems

Boston Scientific Corporation · Guidewire with ICE™ Hydrophilic Coating · Class 2

All models of PT Graphix (6)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08714729254942), received between Dec 4, 2019 and Dec 4, 2019 — classified as 1 injury.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Difficult to Remove1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 4, 2019Difficult to Remove; Detachment of Device or Device Component; Difficult to Remove; Detachment of Device or Device Component

    IT WAS REPORTED THAT DIFFICULTY REMOVING A GUIDEWIRE AND GUIDEWIRE DETACHMENT OCCURRED. THE 80% STENOSED TARGET LESION WAS LOCATED IN THE HIGHLY CALCIFIED CIRCUMFLEX (CX) AND LEFT ANTERIOR DESCENDING ARTERY (LAD). DUE TO THE BIFURCATION TREATMENT (CX TO LAD), A 2.5 X 20MM PROMUS SELECT STENT WAS IMPLANTED IN THE LAD. FOR A KISSING BALLOON TREATMENT, A 182CM PT GRAPHIX GUIDEWIRE WAS INSERTED INTO THE LAD AND THE WIRE WAS PLACED UNDETECTED UNDER A STENT STRUT. AFTER THE KISSING BALLOON TREATMENT, THE PT GRAPHIX WIRE WAS REMOVED, BUT RESISTANCE WAS FELT. DURING REMOVAL, 3MM OF THE PT GRAPHIX WIRE TIP WAS TORN OFF AND FIXED UNDER THE STENT STRUT. NO INTERVENTION WAS PERFORMED TO REMOVE THE TIP FROM THE PATIENT AS IT WAS NOT POSSIBLE TO CROSS THE STENOSIS AND SO IT WAS NOT POSSIBLE TO REMOVE THE TIP FROM THE PATIENT. IT WAS NOTED THAT THE REASON FOR THE TIP DETACHMENT WAS DUE TO THE BIFURCATION STENOSIS. THE PROCEDURE WAS COMPLETED. NO PATIENT COMPLICATIONS RESULTED FROM THIS EVENT AND THE PATIENT WAS REPORTED TO BE STABLE FOLLOWING THE PROCEDURE.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 9410528 ↗

Other WIRE, GUIDE, CATHETER devices