Impulse™ H74916599400Recalls & reported problems
Boston Scientific Corporation · Angiographic Catheter · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08714729304975), received between Dec 17, 2019 and Jul 1, 2024 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Low Blood Pressure/ Hypotension1
- Thrombosis/Thrombus1
- Vascular Dissection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 1, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THERE WAS THROMBUS PRESENT IN THE PATIENT. A LEFT ATRIAL APPENDAGE (LAA) CLOSURE PROCEDURE WAS BEING PERFORMED. A WATCHMAN FXD CURVE ACCESS SYSTEM (WAS) AND A WATCHMAN FLX LAA CLOSURE DEVICE & DELIVERY SYSTEM (WDS) WERE SELECTED TO BE USED. THE PHYSICIAN SUCCESSFULLY PERFORMED THE TRANSSEPTAL PUNCTURE AND THEN INSERTED THE WAS INTO THE PATIENT. THE IMPULSE PIGTAIL CATHETER WAS INSERTED TO HELP POSITION THE WAS IN THE LAA OF THE PATIENT. THE IMPULSE PIGTAIL CATHETER WAS THEN REMOVED FROM THE PATIENT, AND IT WAS NOTED THAT THERE WERE CLOTS ALL OVER THE DEVICE. THE PHYSICIAN ASPIRATED THE WAS, BUT NO THROMBUS REMAINED IN THE PATIENT. THE PHYSICIAN CONTINUED THE PROCEDURE USING THE SAME WAS. THE WDS WAS INSERTED, AND THE CLOSURE DEVICE WAS DEPLOYED IN THE PATIENT. AFTER ALL RELEASE CRITERIA WAS MET THE CLOSURE DEVICE WAS RELEASED FROM THE CORE WIRE OF THE WDS AND SUCCESSFULLY IMPLANTED IN THE LAA OF THE PATIENT. THE PATIENT DID NOT EXPERIENCE ANY OTHER COMPLICATIONS AND IS EXPECTED TO MAKE A FULL RECOVERY.
Patient problems: Thrombosis/Thrombus
MAUDE report 19643570 ↗InjuryDec 17, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED A DISSECTION OCCURRED. A LEFT ATRIAL APPENDAGE (LAA) CLOSURE PROCEDURE WAS BEING PERFORMED. A WATCHMAN TRUSEAL ACCESS SYSTEM (WAS) WAS POSITIONED IN THE LAA AND A 24MM WATCHMAN FLX LAA CLOSURE DEVICE AND DELIVERY SYSTEM (WDS) WAS INSERTED INTO THE WAS. THE CLOSURE DEVICE WAS DEPLOYED, BUT WAS TOO PROXIMAL, SO IT WAS FULLY RECAPTURED. IT WAS DEPLOYED AGAIN, BUT DID NOT MEET THE RELEASE CRITERIA, SO IT WAS FULLY RECAPTURED AGAIN. ON THE THIRD DEPLOYMENT, THE CLOSURE DEVICE DID NOT EXPAND. IT WAS FULLY RECAPTURED AND REMOVED FROM THE PATIENT. ANOTHER 24MM WATCHMAN FLX CLOSURE DEVICE WAS USED IN A DIFFERENT LOBE. IT WAS DEPLOYED, BUT WAS TOO PROXIMAL, SO A FULL RECAPTURE WAS PERFORMED AND THE WDS WAS REMOVED FROM THE PATIENT. AN IMPULSE PIGTAIL CATHETER WAS INSERTED AGAIN INTO THE WAS TO ACHIEVE THE VERY FIRST POSITION. AFTER CONTRAST WAS GIVEN, AN INTIMAL DISSECTION WAS SEEN IN THE LAA. THE DEVICES WERE REMOVED AND THE PROCEDURE WAS ABORTED. THE PATIENT EXPERIENCED LOW BLOOD PRESSURE AND WENT TO THE EMERGENCY ROOM WHERE ATERENOL WAS ADMINISTERED. THE PATIENT IS CURRENTLY FINE AND HAS BEEN DISCHARGED FROM THE HOSPITAL.
Patient problems: Low Blood Pressure/ Hypotension; Vascular Dissection
MAUDE report 9484306 ↗
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page