THRUWAY™ M001492791Recalls & reported problems

Lake Region Medical · Class 2

All models of THRUWAY (5)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 08714729405580), received between Feb 28, 2023 and Oct 28, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Entrapment of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 28, 2024Break; Break

    ADDITIONAL INFORMATION RECEIVED 7 NOVEMBER 2024: 1. LISTING AND MODEL OF OTHER DEVICES USED DURING THE PROCEDURE, INCLUDE THE MODEL, BRAND NAME, SIZES, ETC. - GORE VIABAHN, BOSTON BALLOON BRAVUS. 2. WHEN DURING THE PROCEDURE DID THE EVENT OCCUR? DURING THE PROCEDURE. 3. WAS THE CATHETER STUCK/LOCKED ON THE GUIDEWIRE? OR WAS THERE JUST SIGNIFICANT RESISTANCE BETWEEN THE DEVICES (NOT STUCK)? N/A, THE DEVICE WAS NOT ABLE TO CROSS THE LESION. 4. WAS THE GUIDEWIRE ABLE TO BE REMOVED FROM THE CATHETER UPON REMOVAL FROM THE PATIENT? YES. 5. HOW WERE THE DEVICES REMOVED? THE DEVICE WAS ABLE TO BE REMOVED NORMALLY. 6. DID THE DAMAGE NOTED TO THE WIRE OCCUR POST PROCEDURE DURING HANDLING OR REMOVAL FROM THE CATHETER? N/A, THE DAMAGE NOTED TO THE WIRE IS NOT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20545774 ↗
  • MalfunctionFeb 28, 2023Entrapment of Device; Entrapment of Device

    PER CNF, IT WAS REPORTED THAT: SHAPING? YES A SFA CTO CASE REPORTED THAT THIS DEVICE GOT STUCK INSIDE THE BODY WITH A PROMINENT RAPTOR THAT WAS USED IN COMBINATION. WHEN THIS DEVICE WAS ATTEMPTED TO BE PULLED APART OUTSIDE THE BODY, THE SHAFT OF THIS DEVICE BENT, AND ITS USE WAS DISCONTINUED. IT IS SPECULATED THAT A THROMBUS MAY HAVE ATTACHED TO IT. ADDITIONAL INFORMATION RECEIVED FEBRUARY 27, 2023: 1. LISTING AND MODEL OF OTHER DEVICES USED DURING THE PROCEDURE, INCLUDE THE MODEL, BRAND NAME, SIZES, ETC.? GUIDING SHEATH: MEDIKIT PARENT 60. 2. PLEASE PROVIDE THE MODEL AND SIZE OF THE "PROMINENT RAPTOR"? - LUMEN 0.018, LENGTH 135. 3. IT'S REPORTED, "WHEN THE DEVICE WAS ATTEMPTED TO BE PULLED APART OUTSIDE THE BODY, THE SHAFT OF THIS DEVICE BENT". A. WHICH DEVICE BENT, THE GUIDEWIRE OR CATHETER OR BOTH? THE GUIDEWIRE. THE CATHETER SEEMED TO STRETCHED SLIGHTLY. 4. WAS THE CATHETER STUCK/LOCKED ON THE GUIDEWIRE OR WAS THERE JUST SIGNIFICANT RESISTANCE BETWEEN THE DEVICES (NOT STUCK)? THERE WAS SIGNIFICANT RESISTANCE BETWEEN THE DEVICES. 5. HOW WERE THE DEVICES REMOVED FROM THE PATIENT? BOTH THE PROMINENT RAPTOR AND THE GUIDEWIRE WERE TAKEN OUT OF THE BODY, AND THEY WERE TRYING TO BE SE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16455155 ↗

Other Wire, Guide, Catheter devices

All Wire, Guide, Catheter devices →