Coyote™ H74939186251210Recalls & reported problems

Boston Scientific Corporation · PTA Balloon Dilatation Catheter · Class 2

All models of Coyote (55)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 08714729796527), received between Jul 12, 2019 and Aug 12, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Entrapment of Device” (2 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 3, 2025Class IIOpen, Classified

    Boston Scientific is initiating the removal of certain batches of Coyote" Over-the-Wire (OTW) Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter devices due to the potential for inflation/deflation difficulty during use in the peripheral vasculature. An internal investigation found that a manufacturing process variation resulted in catheters that may not properly inflate/deflate. This was limited to Coyote OTW batches manufactured from 12Sep2025 through 13Oct2025. The processing variation has since been addressed. No other material numbers or batches are impacted by this removal.

    Z-1042-2026 · Root cause: Process change control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Entrapment of Device2
  • Difficult to Advance1
  • Leak/Splash1
  • Material Deformation1
  • Material Integrity Problem1
  • Material Rupture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 12, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT BALLOON RUPTURE OCCURRED. THE 70% STENOSED TARGET LESION WAS LOCATED IN THE MODERATELY TORTUOUS AND MODERATELY CALCIFIED VESSEL BELOW THE KNEE. A 2.5MM X 120MM X 150CM COYOTE OTW BALLOON CATHETER WAS ADVANCED FOR DILATATION. HOWEVER, DURING FIRST INFLATION AT NOMINAL ATMOSPHERES, THE BALLOON BURST. THE DEVICE WAS REMOVED, AND THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE. NO PATIENT COMPLICATIONS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22783269 ↗
  • MalfunctionJun 30, 2021Leak/Splash; Leak/Splash

    REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 16-JUN-2021. IT WAS REPORTED THAT BALLOON LEAK OCCURRED. THE 99% STENOSED TARGET LESION WAS LOCATED IN MILDLY TORTUOUS SUPERFICIAL FEMORAL ARTERY. A 2.5MM X 120MM X 150CM COYOTE BALLOON CATHETER WAS ADVANCED FOR DILATATION. HOWEVER, DURING INFLATION AT 4-5 ATMOSPHERES, THE BALLOON BURST AND CONTRAST LEAK WAS NOTICED. THE DEVICE WAS REMOVED IN NORMAL FASHION AND THE PROCEDURE WAS COMPLETED WITH ANOTHER OF SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED. HOWEVER, RETURNED DEVICE ANALYSIS REVEALED BALLOON PINHOLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12096866 ↗
  • MalfunctionMar 11, 2021Entrapment of Device; Material Integrity Problem; Entrapment of Device; Material Integrity Problem

    IT WAS REPORTED THAT CATHETER ENTRAPMENT OCCURRED. THE 85 PERCENT STENOSED TARGET LESION WAS LOCATED IN A MILDLY CALCIFIED AND MILDLY TORTUOUS LESION BELOW THE KNEE. A 2.5MM X 120MM X 150CM, OTW COYOTE BALLOON CATHETER WAS ADVANCED OVER THE GUIDEWIRE. HOWEVER, AFTER CROSSING ABOUT 20CM ON THE GUIDEWIRE, THE CATHETER WAS STUCK AND THE PHYSICIAN WAS UNABLE TO ADVANCE OR RETRIEVE THE CATHETER. IT WAS OBSERVED THAT THE CATHETER TIP WAS KINKED. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. THERE WERE NO PATIENT COMPLICATIONS NOR INJURIES REPORTED AND THE PATIENT STATUS WAS STABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11464596 ↗
  • MalfunctionJul 12, 2019Entrapment of Device; Difficult to Advance; Material Deformation; Entrapment of Device; Difficult to Advance; Material Deformation

    IT WAS REPORTED THAT A BALLOON DEVICE KINKED AND FROZE ON THE GUIDE WIRE. THE TARGET LESION WAS LOCATED IN MODERATELY CALCIFIED AND MILDLY TORTIOUS RIGHT TIBIALIS ANTERIOR. THE TIBIALIS ANTERIOR WAS RECANALIZED WITH A 300 CM V 14 CONTROL WIRE (GUIDEWIRE). A 2.5MM X 120MM X 150CM COYOTE BALLOON WAS PLACED OVER THE GUIDEWIRE. BECAUSE OF STRONG FORCES FORM THE HARD CALCIFIED VESSEL, THE COYOTE KINKED WITH THE GUIDEWIRE AND NO MOVEMENT WAS POSSIBLE. FORWARD AND BACKWARD MOVEMENTS WITH THE WIRE IN THE CATHETER WERE NOT POSSIBLE. THE DEVICES WERE REMOVED FROM THE PATIENT AND IT WAS NOTICED THAT A 3MM TIP FROM THE WIRE WAS MISSING. IT WAS FIXED BY ADVANCING ANOTHER CATHETER IN THE VESSEL WALL. INTERVENTION WAS SUCCESSFULLY FINISHED AND THE PATIENT STATUS WAS WELL. IT WAS NOTED THAT THE CAUSE OF THE EVENT WAS RELATED TO THE KINK OF THE COYOTE BALLOON CATHETER. NO ADDITIONAL PATIENT COMPLICATIONS WERE REPORTED IN RELATION TO THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8784489 ↗

Other CATHETER, PERCUTANEOUS devices

All CATHETER, PERCUTANEOUS devices →