V-14™ Control Wire™ H74939216930020Recalls & reported problems
Boston Scientific Corporation · Guidewire with ICE™ Hydrophilic Coating · Class 2
All models of V-14 Control Wire (7)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 08714729799276), received between Oct 15, 2019 and Oct 15, 2025 — classified as 2 injuries, 5 malfunctions.
The most frequently reported specific device problem is “Material Integrity Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Integrity Problem3
- Adverse Event Without Identified Device or Use Problem2
- Detachment of Device or Device Component2
- Difficult to Remove2
- Packaging Problem2
- Contamination1
- Fracture1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient2
- Foreign Body In Patient1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 15, 2025Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem; Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT GUIDEWIRE TIP DETACHMENT OCCURRED. THE PATIENT PRESENTED WITH COLD LEG AND UNDERWENT ANGIOGRAM. THE TARGET LESIONS WERE LOCATED IN THE 99% OCCLUDED SUPERFICIAL FEMORAL ARTERY (SFA) AND 100% OCCLUDED POSTERIOR TIBIAL ARTERY (PTA). THE LESION CHARACTERISTICS WERE MODERATELY TORTUOUS AND MODERATELY CALCIFIED. AFTER ADVANCING A 300CM ANGLED TIP V-14 CONTROL WIRE, A 2.5MM X 220MM X 150CM COYOTE BALLOON CATHETER WAS ADVANCED OVER THE WIRE; HOWEVER, RESISTANCE WAS NOTED. FOLLOWING DILATATION, AN ATTEMPT WAS MADE TO ADVANCE THE WIRE AND THE BALLOON FURTHER DISTALLY WHEN THE TIP OF THE WIRE SHEARED OFF. THE DETACHED TIP WAS LEFT INSIDE THE PATIENT UP AGAINST THE VESSEL WALL. THERE WERE NO PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.
Patient problems: Foreign Body In Patient
MAUDE report 23305717 ↗MalfunctionFeb 6, 2023Difficult to Remove; Material Integrity Problem; Packaging Problem; Difficult to Remove; Material Integrity Problem; Packaging Problem
IT WAS REPORTED THAT REMOVAL DIFFICULTIES OCCURRED. THE PATIENT UNDERWENT LOWER EXTREMITY RUNOFF. A 300CM V-14 CONTROL WIRE WAS REMOVED FROM THE HOOP AND USED DURING PROCEDURE. HOWEVER, THERE WAS RESISTANCE IN REMOVING THE V-14 GUIDEWIRE FROM A NON-BOSTON SCIENTIFIC CATHETER INSIDE THE VESSEL. THE PACKAGING AS WELL AS THE TIP OF THE DEVICE WAS NOTED TO BE DAMAGED. THE PROCEDURE WAS COMPLETED WITH ANOTHER V-14 GUIDEWIRE. THERE WERE NO PATIENT COMPLICATIONS NOR INJURIES REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16308246 ↗MalfunctionFeb 3, 2023Difficult to Remove; Material Integrity Problem; Difficult to Remove; Material Integrity Problem
IT WAS REPORTED THAT REMOVAL DIFFICULTIES OCCURRED. THE PATIENT UNDERWENT LOWER EXTREMITY RUNOFF. A 300CM V-14 CONTROL WIRE WAS REMOVED FROM THE HOOP AND USED DURING PROCEDURE. HOWEVER, THERE WAS RESISTANCE IN REMOVING THE V-14 GUIDEWIRE FROM A NON-BOSTON SCIENTIFIC CATHETER INSIDE THE VESSEL. TIP DAMAGE WAS ALSO NOTED. THE PROCEDURE WAS COMPLETED WITH ANOTHER V-14 GUIDEWIRE. THERE WERE NO PATIENT COMPLICATIONS NOR INJURIES REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16294616 ↗MalfunctionOct 5, 2022Contamination; Packaging Problem; Contamination; Packaging Problem
IT WAS REPORTED THAT DEVICE STERILITY WAS COMPROMISED. UPON OPENING OF A 300CM LONG TAPER ANGLED TIP V-14 CONTROL WIRE GUIDEWIRE, IT WAS NOTED THAT THE TOP OF THE STERILE SLEEVE WAS DAMAGED AND SEEN TO BE NO LONGER STERILE. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15542729 ↗InjuryOct 20, 2021Fracture; Fracture
IT WAS REPORTED THAT GUIDEWIRE FRACTURE OCCURRED. A 300CM ANGLED TIP V-14 CONTROL WIRE WAS USED DURING VASCULAR PROCEDURE. HOWEVER, IT WAS NOTICED THAT THE GUIDEWIRE FRACTURED. THE DEVICE WAS REMOVED WITH A SNARE AND THE PROCEDURE WAS COMPLETED WITH A .014 WIRE. NO PATIENT COMPLICATIONS REPORTED AND THE PATIENT STATUS WAS STABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12665590 ↗MalfunctionDec 4, 2019Material Integrity Problem; Adverse Event Without Identified Device or Use Problem; Material Integrity Problem; Adverse Event Without Identified Device or Use Problem
REPORTABLE BASED ON DEVICE ANALYSIS COMPLETED ON 20NOV2019. IT WAS REPORTED THAT TIP DAMAGE OCCURRED. THE TARGET LESION WAS LOCATED IN THE TIBIAL ARTERY. A 300CM ANGLED TIP V-14 CONTROL WIRE GUIDEWIRE WAS ADVANCED FOR TREATMENT. HOWEVER, DURING PROCEDURE, IT WAS NOTED THAT THE TIP OF THE WIRE WAS FRAYED. THE PROCEDURE WS COMPLETED WITH A DIFFERENT DEVICE. THERE WERE NO PATIENT COMPLICATIONS NOR INJURIES REPORTED. HOWEVER RETURNED ANALYSIS REVEALED DETACHED COATING.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9412002 ↗InjuryOct 15, 2019Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT GUIDE WIRE TIP DETACHMENT OCCURRED. THE TARGET LESION WAS LOCATED IN THE ANTERIOR TIBIAL ARTERY . A 300CM V-14 CONTROL WIRE WAS ADVANCED INTO THE TARGET LESION. HOWEVER, THE TIP BROKE OFF AND THE PHYSICIAN ADDED AN HOUR OF WORK TIME TO RETRIEVE THE DETACHED TIP USING A SNARING DEVICE. CATHETERIZATION WAS CONTINUED USING A DIFFERENT WIRE AND THE PROCEDURE WAS COMPLETED. NO PATIENT COMPLICATIONS WERE REPORTED. IT WAS FURTHER REPORTED THAT THE TARGET LESION WAS MODERATELY CALCIFIED WITH APPROXIMATELY 80% STENOSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9195155 ↗
Other WIRE, GUIDE, CATHETER devices
- HI-TORQUE BALANCE MIDDLEWEIGHT UNIVERSAL II 1009664Abbott Vascular Inc. · WIRE, GUIDE, CATHETER321 reports
- SYNCHRO 14 M00313010Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls220 reports
- PressureWire™ C12059Lightlab Imaging, Inc. · WIRE, GUIDE, CATHETER1 death296 reports
- SYNCHRO 2 M00326410Stryker Corporation · WIRE, GUIDE, CATHETER2 recalls155 reports
- ENROUTE .014" Guidewire 11686-01Silk Road Medical, Inc. · Wire, Guide, Catheter2 deaths228 reports
- ARROW IPN035915Teleflex Incorporated · WIRE, GUIDE, CATHETER217 reports
- OmniWire Pressure guide wire 89185Philips Image Guided Therapy Corporation · Wire, Guide, Catheter1 recall1 death160 reports
- ARROW IPN055780Teleflex Incorporated · Wire, guide, catheter4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page