2cm Peripheral Cutting Balloon® M001PCB6020900Recalls & reported problems

Boston Scientific Corporation · Microsurgical Dilatation Device · Class 2

All models of 2cm Peripheral Cutting Balloon (12)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 08714729813743), received between Jan 24, 2019 and Dec 1, 2024 — classified as 1 injury, 4 malfunctions.

The most frequently reported specific device problem is “Material Rupture” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Rupture3
  • Inflation Problem2
  • Device-Device Incompatibility1
  • Difficult to Advance1
  • Difficult to Remove1
  • Material Integrity Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient2
  • Hematoma1
  • Hemorrhage/Blood Loss/Bleeding1
  • Laceration(s)1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 1, 2024Inflation Problem; Material Rupture; Inflation Problem; Material Rupture

    IT WAS REPORTED THAT BALLOON RUPTURE OCCURRED. A 6.00MM/2.0CM/90CM PERIPHERAL CUTTING BALLOON WAS ADVANCED OVER THE WIRE INTO THE FISTULA. DURING FIRST INFLATION, THE BALLOON DID NOT INFLATE AND POPPED FOR UNKNOWN REASON. THE DEVICE WAS REMOVED INTACT WITHOUT ISSUE AND THE PROCEDURE WAS COMPLETED WITH OTHER PRODUCTS. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20815491 ↗
  • InjuryOct 4, 2021Difficult to Remove; Device-Device Incompatibility; Difficult to Advance; Difficult to Remove; Device-Device Incompatibility; Difficult to Advance

    IT WAS REPORTED THAT REMOVAL DIFFICULTIES WERE ENCOUNTERED AND THE BALLOON CUT THE SHEATH. THE TARGET LESION WAS LOCATED IN THE LEFT BRACHIAL ACCESS. A 6.00MM/2.0CM/90CM PERIPHERAL CUTTING BALLOON (PCB) WAS SELECTED FOR USE. DURING REMOVAL OF THE PCB, RESISTANCE WAS FELT UPON ENTERING THE SHEATH. THE DEVICE WAS REMOVED AND CONTINUED TO TREAT THE LESION WITH A DRUG COATED BALLOON. HOWEVER, SOME BLEEDING WAS NOTICED AT THE SHEATH SITE AND AFTER EXAMINING THE SHEATH IT WAS NOTICED THAT IT HAD BEEN COMPROMISED BY A HORIZONTAL CUT. NO PATIENT COMPLICATIONS REPORTED. IT WAS FURTHER REPORTED VIA MEDWATCH # (B)(4) THAT THE PERCENTAGE OF STENOSIS WAS 50%, AND LESION HAD FOCAL SEVERITY OF CALCIFICATION AND VERY LITTLE OF TORTUOUSITY. ALSO, THE BALLOON WAS SLOWLY REMOVED AFTER PROPER DEFLATION. THE BLEEDING WAS NOTED ONLY AFTER THE REMOVAL OF THE SHEATH. IN ADDITION, A CUTTING BALLOON WAS USED TO OPEN THE ARTERY THAT SUPPLIES THE ARM ENDOVASCULARLY. DURING REMOVAL, THE BLADES OF THE DEVICE LACERATED THE ARTERY OF THE PATIENT AT THE ENTRY SITE AS WELL AS THE SHEATH WHICH WAS REMOVED. THE BLADES ARE SUPPOSED TO BE RETRACTED TO PREVENT ANY DAMAGE WHEN THE BALLOON WAS DEFLATED. HOWEVER, THE BLADE

    Patient problems: Hematoma; Hemorrhage/Blood Loss/Bleeding; Laceration(s); No Clinical Signs, Symptoms or Conditions

    MAUDE report 12569133 ↗
  • MalfunctionApr 15, 2021Inflation Problem; Material Integrity Problem; Inflation Problem; Material Integrity Problem

    IT WAS REPORTED THAT BALLOON SHAF GOT INFLATED. THE TARGET LESION WAS LOCATED IN THE BRACHIALCEPHALIC VEIN. A 6.00MM/ 2.0CM/ 90CM PERIPHERAL CUTTING BALLOON WAS SELECTED FOR USE. DURING PROCEDURE, THE BALLOON DID NOT INFLATE INSTEAD IT FILLED IN THE SPACE BEFORE THE BALLOON AND CREATED A BUBBLE IN THE CATHETER SHAFT. THE DEVICE WAS REMOVED OVER THE WIRE AND COMPLETED THE PROCEDURE WITH ANOTHER OF SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11672203 ↗
  • MalfunctionSep 10, 2019Material Rupture; Material Rupture

    IT WAS REPORTED THAT A BALLOON RUPTURE OCCURRED. THE 75% STENOSED TARGET LESION WAS LOCATED IN A STENT GRAFT OF THE RIGHT SUPERFICIAL FEMORAL ARTERY. A 6.00MM/2.0CM/90CM OTW PERIPHERAL CUTTING BALLOON WAS SELECTED FOR USE. DURING PROCEDURE, IT WAS NOTED THAT THE BALLOON RUPTURED UPON INFLATION. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO PATIENT COMPLICATIONS WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8982410 ↗
  • MalfunctionJan 24, 2019Material Rupture; Material Rupture

    IT WAS REPORTED THAT BALLOON RUPTURE OCCURRED. A 6.00MM/2.0CM/90CM PERIPHERAL CUTTING BALLOON WAS SELECTED FOR USE. DURING THE PROCEDURE, THE BALLOON WAS INSERTED INTO THE PATIENT AND WAS INFLATED THREE TIMES SUCCESSFULLY. HOWEVER, THE BALLOON COULD NOT BE INFLATED COMPLETELY DURING FOURTH INFLATION AND RUPTURED. THE DEVICE WAS THEN REMOVED FROM THE PATIENT AND WAS STILL INTACT; NO PARTS OF THE BALLOON WERE LEFT INSIDE THE PATIENT'S BODY. THE PROCEDURE WAS COMPLETED WITH ANOTHER OF THE SAME DEVICE. NO COMPLICATIONS REPORTED AND THE PATIENT IS STABLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8275280 ↗

Other Catheter, percutaneous, cutting/scoring devices

All Catheter, percutaneous, cutting/scoring devices →